Corrosion Control Test Kit
-
Metal Strip Corrosion Test Bombs
Koehler…washed and evaluated for corrosion. The fully insulated, thermostatically controlled water bath features a constant water level device. The bath is used in conjunction with the Batch Conversion Kit to immerse six 350 mL test tubes for silver strip corrosion tests. Bath features stainless steel,…
-
Corrosion Control Test Kit
LaMotte…water Includes TDS pocket tester to meet EPA requirements for corrosion testing Packaged in a portable carrying case for on-site use. Reagents for 50 tests of each parameter are supplied. Each unit includes tests for P & T alkalinity, calcium hardness, temperature, pH and…
-
Carbohydrazide CHEMets Kit
CHEMetrics…colored complex in direct proportion to the carbohydrazide concentration. Test results are expressed as ppm (mg/L) carbohydrazide. Kit comes in a plastic case and contains everything needed to perform 30 tests: Refill, Comparator, Activator Solution, 25 mL sample cup, and instructions.…
-
pH EndPoint ID® Test Kits
labForce® (powered by Thomas Scientific)pH is a very important test for industrial water treatment. Corrosion and scale can be controlled with good pH measurement. Each kit is packaged in a durable plastic case and includes all items to complete approximately 60-75 tests.
-
…at +15°C to +25°C. Hazard: Corrosive Aluminium compounds are used as precipitating agents (flocculants) for water treatment plants, swimming baths and in paper manufacturing. The test can usually be applied directly here to test the effectiveness of the filter in process control.
-
Copper (Soluble) Vacu-vials Kit
CHEMetrics…of copper is an important means of monitoring the corrosion of condensate systems and heat exchangers. The Bathocuproine Method Reference: APHA Standard Methods, 23rd ed., Method 3500-Cu C - 1999. CHEMetrics’ test kits employ the bathocuproine reagent. Bathocuproine…
-
Hydrazine CHEMets Kit
CHEMetrics…various chemical processes and in boiler water as an oxygen scavenger. To control corrosion, residual hydrazine typically is maintained in the 0.05 to 0.1 mg/L range. Higher levels may be used to guard against corrosion when the boiler is out of service for an extended period. The PDMAB Method…
-
Copper (Soluble) CHEMets Kit
CHEMetrics…of copper is an important means of monitoring the corrosion of condensate systems and heat exchangers. The Bathocuproine Method Reference: APHA Standard Methods, 22nd ed., Method 3500-Cu C - 1999. CHEMetrics’ test kits employ the bathocuproine reagent. Bathocuproine…
-
Alkalinity Titrets® Kits
CHEMetrics… Alkalinity inhibits corrosion in boiler and cooling waters. It is also measured as a means of controlling water and wastewater treatment processes or the quality of various process waters. Alkalinity (total) ASTM D 1067-06, Acidity or Alkalinity of Water, Test method B. APHA Standard…
-
Phosphate Vacu-vials® Kits
CHEMetrics…4500-P D-2005. Test kits employing this chemistry utilize a stannous chloride reduction. Phosphate reacts with ammonium molybdate and is then reduced by stannous chloride to form a blue complex. Results are expressed as ppm (mg/L) PO4. Our Phosphate Test Kit comes in a cardboard…
-
Phosphate CHEMets® Kits
CHEMetrics… The Vanadomolybdophosphoric Acid Method References: ASTM D 515-82, Phosphorous in Water, Test Method C. APHA Standard Methods, 23rd ed., Method 4500-P C-1999. In test kits employing the vanadomolybdophosphoric acid method, phosphate reacts with ammonium molybdate under acid…
-
Hydrazine VACUettes Kit, Range: 0-50 ppm
CHEMetrics…various chemical processes and in boiler water as an oxygen scavenger. To control corrosion, residual hydrazine typically is maintained in the 0.05 to 0.1 mg/L range. Higher levels may be used to guard against corrosion when the boiler is out of service for an extended period. The PDMAB Method…
-
Hydrazine VACUettes Kit, Range: 0-12.5 ppm
CHEMetrics…various chemical processes and in boiler water as an oxygen scavenger. To control corrosion, residual hydrazine typically is maintained in the 0.05 to 0.1 mg/L range. Higher levels may be used to guard against corrosion when the boiler is out of service for an extended period. The PDMAB Method…
-
Hydrazine VACUettes Kit, Range: 0-500 ppm
CHEMetrics…various chemical processes and in boiler water as an oxygen scavenger. To control corrosion, residual hydrazine typically is maintained in the 0.05 to 0.1 mg/L range. Higher levels may be used to guard against corrosion when the boiler is out of service for an extended period. The PDMAB Method…
-
Hydrazine VACUettes Kit, Range: 0-25 ppm
CHEMetrics…various chemical processes and in boiler water as an oxygen scavenger. To control corrosion, residual hydrazine typically is maintained in the 0.05 to 0.1 mg/L range. Higher levels may be used to guard against corrosion when the boiler is out of service for an extended period. The PDMAB Method…
-
MIDI-VAP 4000 Distillation Systems
DWK Life Sciences (Kimble)Ammonia/Phenols and Cyanide Models Available Corrosion resistant PTFE-coated glass 30" x 14.25" footprint Overtemp protection switch Automatic shutoff MIDI-VAP 4000 Systems feature a pre-programmed digital controller with automated shut-off when reaction time is completed. They use…
-
USA Digital Incubators
LW ScientificThe digitally controlled USA Incubators from LW Scientific are perfect for various applications such as cultures, egg incubation, test kits, fluid bag warming, and other microbiological uses in pediatric, physician, and hospital labs. This new line of incubators is designed, engineered, and…
