Autoclave Pouch

Compare Tool

Select up to 3 products

Autoclave Pouch
1 - 29 of 29
Sort
View
Show
  • Keystone Cleanroom Products

    1073B Tyvek® / HDPE autoclave bags are ideal for steam sterilization of pharmaceutical components such as vial and syringe stoppers and caps. Also a good choice for heavy equipment parts where visibility into the bag is required. Manufactured and packaged in a controlled cleanroom…

  • Ampac Flexibles

    …Foil pouches are ideal for light sensitive objects requiring a nontransparent packaging solution. These pouches provide the best oxygen and moisture barrier of any Kapak by Ampac stock pouch. FoilPAK pouches can withstand temperatures up to 130°C (266°F), and can be used in autoclave

  • Propper Manufacturing

    pouch corners and covered by the extension of the transparent film beyond the sealed area. This guarantees protection of the indicators from direct contact with metal trays or instruments, yet does not obstruct observation of the indicator color change. Features: In steam autoclave:

  • …Tyvek® autoclave bags are ideal for steam sterilization of pharmaceutical components such as vial and syringe stoppers and caps as well as heavy equipment parts with sharp edges. Manufactured and packaged in a controlled cleanroom environment Steam sterilization indicator Autoclavable

  • …Manufactured and packaged in a controlled cleanroom environment Convenient Self-sealing closure system Steam sterilization indicator Autoclavable at 121 to 125 °C Tear and puncture resistant, hydrophobic, lint-free 100% Medical Grade 1073B Tyvek® permits fast steam penetration…

  • McKesson Autoclave Pouches - Self Sealing 7-1/2 X 13 Inch For use with Steam and Ethylene Oxide (EO) Sterilizers They are self-sealing, which makes them easy to open and close No autoclave tape necessary Internal and external chemical indicators Lead free ink Not made with…

  • DWK Life Sciences (Wheaton)

    Fitting any small to mid-size laboratory device, the Qualitix® single use pouches provide easy and effective wrapping of items requiring sterilization. Made with robust medical grade paper, the pouches tightly close with a self-sealing strip to maintain sterility. Content remains always visible…

  • Autoclavable at 121 to 125 °C Peels open cleanly, chevron peel Hydrophobic Tear and puncture resistant, lint-free Steam Indicator A significant upgrade over paper based steam sterilization pouches. These Tyvek® peel pouches will not rip or puncture like paper based autoclave

  • Tyvek® 1422A autoclave bags can be used as either the inner, or outer bag for the steam sterilization of pharmaceutical change parts. Tear and puncture resistant Designd to be heat sealed closed Eliminates need to cut material and the use of autoclave tape Fast and consistent for…

  • Keystone Cleanroom Products

    Improve the performance, microbial barrier and cleanliness of your autoclave peel pouches. Manufactured and packaged in a controlled cleanroom environment Autoclavable at 121 to 125 °C Peels open cleanly Chevron peel Tear and puncture resistant Hydrophobic Lint-free Heat seals…

  • …self-sealing autoclave bags can be used as either the inner, or outer bag for the steam sterilization of pharmaceutical change parts. Tear and puncture resistant Convenient and reliable "dual seal"self-sealing closure Eliminates need to cut material and the use of autoclave tape …

  • …and cleanliness of your autoclave peel pouches. Manufactured and packaged in a controlled cleanroom environment Integrated Hang Hole is ideal for use with Isolator VHP decontamination cycles Easy, fast and reliable self-sealing closure system Autoclavable at 121 to 125 °C Peels…

  • Neutralize Autoclave Odors with a Choice of Four Fragrances Heat-released deodorant pads neutralize autoclave odors with one of four pleasant scents. Simply open foil pouch and place pad in bag prior to autoclaving Pads have a three year life span; will last longer if stored in a…

  • Keystone Cleanroom Products

    …SOP's 2-ply Steam sterilization indicator Autoclavable up to 135 °C Tear and puncture resistant Significant process improvement compared to wrapping with BioShield paper Eliminates need to cut material and the use of autoclave tape These BHD filling needle bags stay in place…

  • Keystone Cleanroom Products

    …SOP's 2-ply Steam sterilization indicator Autoclavable up to 135 °C Tear and puncture resistant Significant process improvement compared to wrapping with BioShield paper Eliminates need to cut material and the use of autoclave tape Standardize and simplify the way equipment…

  • MP Biomedicals

    …reagents are combined in the accurate proportions according to the LB formulation and thoroughly blended for a uniform distribution. A sample of the blended formulation was used to prepare the liquid. The combinations were mixed to dissolve components and then autoclaved at 121°C for 15 minutes.

  • MP Biomedicals

    …are combined in the proper proportions according to the YPD Agar formulation and thoroughly blended for a uniform distribution. A sample of the blended formulation is used to prepare agar medium. The combinations are mixed to dissolve components and then autoclaved at 121°C for 15 minutes.

  • MP Biomedicals

    …mixed by hand for about 1 minute to dissolve the dextrose and autoclaved at 121°C for 15 minutes. After cooling to 50°C plates were poured. SD Medium-Leu (DOB with CSM-Leu) with agar was visually inspected after autoclaving for complete dissolution of components. The pH of the medium was…

  • MP Biomedicals

    …Chosen reagents are combined in the accurate proportions according to the formula and thoroughly blended for a uniform distribution. A sample of the blended formulation was used to prepare liquid. The combinations were mixed to dissolve components and autoclaved at 121°C for 15 minutes.

  • MP Biomedicals

    …of SD Medium-Leu-Trp only or 27.4g of SD Medium-Leu-Trp and 17g Agar to 1000ml of purified water. The combinations were mixed by hand for about 1 minute to dissolve the dextrose and autoclaved at 121°C for 15 minutes. After cooling to 50°C, plates of SD Medium-Leu-Trp with Agar were poured.

  • Our largest automatic table top autoclave. Features a closed door active drying system. Perfect for multi-doctor practices, clinics or surgery centers. 15"x 30" chamber accommodates longer instruments or a large number of small instruments. Capacity for 15 full size IMS cassettes. 2 year…

  • Keystone Cleanroom Products

    … Hydrophobic Autoclavable at 121 to 125 °C Peels open cleanly, lint-free Tear and puncture resistant A significant upgrade over paper based steam sterilization tubing . These Tyvek® peel pouches will not rip or puncture like paper based autoclave pouches routinely do. The…

  • MP Biomedicals

    …dissolve the dextrose and autoclaved at 121 °C for 15 minutes. After cooling to 50 °C plates were poured. Recommended Use Add contents of the pouch (13.7 g) to 500 mL or (27.4 g) to 1000 mL of distilled, deionized water. Add agar if pouring plates. Autoclave at 121 °C for 15…

  • …on the entire petri dish or plate surface. Smooth spreading surface with slight upward return reduces the risk of damaging agar sample. Spreaders are manufactured of polypropylene and pre-sterilized, eliminating the need for flaming or autoclaving. Packaged individually in a peel back pouch.

  • Protect sterilized items Two versions Guard against contaminants Heat sealer ordered separately Versatile sterility maintenance covers are used to protect sterilized products from bacteria, moisture and dust, reducing their susceptibility to environmental contamination. …

  • Keystone Cleanroom Products

    …wrapping SOP's Steam sterilization indicator Autoclavable up to 135 °C Tear and puncture resistant Significant process improvement compared to wrapping with BioShield paper Eliminates need to cut material and the use of autoclave tape Standardize and simplify the way equipment…

  • quick-ship

    Propper Manufacturing

    …alternative to paper-plastic pouches. All-paper bags due to steam penetration through all sides of the bag allow for adequate air removal, steam contact, and drying. For that purpose paper-plastic pouches, according to section 8.3.4 “Paper-plastic pouches" of ANSI/AAMI ST-79:2010, are not…

  • quick-ship

    Globe Scientific

    This adhesive tape is used to seal autoclave bags and pouches and changes color when the contents have passed through a sterilization cycle. Each roll is 165 feet (50m) long. 1181C23 is used when using autoclave sterilization (20 ft. at +121°C, 10 ft. at +125°C and 5 ft. at…

  • quick-ship

    Globe Scientific

    …the surface of agar plates without gouging or cutting the medium. The spreaders are supplied sterile so there is no need to flame sterilize or autoclave. Durable, non-breakable polystyrene (PS) spreaders pose no safety hazard like glass spreaders L-shaped for convenient…

Compare Tool

Select up to 3 products