  • General Purpose Epoxy-Body ORP Electrode

    Oakton

    The Ag/AgCl combination reference electrodes have an impact-resistant epoxy body. Electrodes provide a fast, stable response and are ideal for prolonged readings. Gel-filled design requires virtually no maintenance. 127 mm L x 12 mm diameter with maximum 176F (80C) temperature. Combine…

  • Aldrich® glass reference electrode General purpose, reference, Ag/AgCl

    MilliporeSigma

    Application pH, titrations General Description The reference electrode is used as a pair with an indication electrode to make a measurement. All types supplied with a 30 in. lead. All reference half-cells have a universal reference pin connector. Legal Information Aldrich is a…

  • Micro-pH Combination Electrode, NMR, Thermo Orion 9826BN

    Thermo Scientific Orion

    Immersion depth is 2 mm, designed for NMR cells. pH range is 0-14. Temperature range is -5 to 100°C. Dimensions: 228 mm x 2.5 mm; tip diameter: 2.5 mm. Type reference: Ag/AgCl.

  • Reference Electrodes For ISEs

    Thermo Scientific Orion

    …chamber to circumvent incompatibility of inner filling solution with ions such as Ag + , Cl - , S = and ClO - 4. Requirements of this reference electrode for particular Thermo Orion specific ion electrodes are indicated in their respective descriptions. Range 10 to 100°C. Potential…

  • BlueLine 25-2 pH Electrode

    SI Analytics

    Plastic shaft, fibre-junction, gel electrolyte Ag/AgCl-reference system, cylinder membrane A glass, 2 m fixed cable with BNC plug, length 120 mm, 12 mm Ø -5...+80 °C, 0...14 pH

  • Replacement pH Electrode for pH 5+ and pH 6+ Meters

    Oakton

    The Ag/AgCl combination reference electrodes have an impact-resistant epoxy body. Electrodes provide a fast, stable response and are ideal for prolonged readings. Gel-filled design requires virtually no maintenance. 127 mm L x 12 mm diameter with maximum 176F (80C) temperature.

  • Combination Electrodes

    Sensorex

    …glass electrode and sealed Ag-AgCl reference electrode in a single stem Range pH 0 to 14, 0° to 100°C Usable at pressures from 0 to 100 psig (690 kPa) Offered in choice of types, each with US Standard or BNC Connector The flat-tip electrodes have pH electrode and porous…

  • AgCl 62 Metal Combination Electrode

    Lab Synergy

    Metal combination electrode for halogenide titrations, Glass shaft, platinum junction, electrolyte KNO3 2 mol/l + KCl 0.001 mol/l, Ag/AgCl-reference system, sensor silver cap 4 mm Ø, chlorinated, plug head, length 120 mm, 12 mm Ø, -5...+100 °C.

  • Micro-pH Electrode, Long, Thermo Orion 9810BN

    Thermo Scientific Orion

    Immersion depth is 1 mm and requires only 0.5 mL of sample. pH range is 0-14. Temperature range: -5 to 100°C. Dimensions: 120 mm x 6 mm; tip diameter: 1.3 mm. Type reference: Ag/Ag/Cl.

  • Orion Double Junction pH Electrodes

    Thermo Scientific Orion

    Low maintenance and refillable electrodes that features an isolated Ag/AgCl reference system, so silver does not make contact with the sample.

  • "Potassium chloride solution, for Ag/AgCl electrodes, ~3 M KCl"

    MilliporeSigma

    Synonyms: Potassium chloride solution saturated with AgCl Formula: KCl Formula Weight: 74.55 CAS No.: 7447-40-7 Density: 1.13 g/mL at 20 °C Application: Electrolyte filling solution for Ag/AgCl reference electrodes General description: Visit our Sensor Applications portal to…

  • PlatinumLINE Electrodes

    Sartorius

    Fast and accurate results with high quality materials, low resistance A type glass membrane or unique Platinum junctions with patented Ag/AgCl reference system. Notes: pH is BNC connection. ATC is 2.5 mm connection. Cable length is 1.5 mm.

  • Triode pH Electrode; Combination pH/Temperature Probe

    Thermo Scientific Orion

    Waterproof connector pH range: 0-14 Temperature range: 0-90°C Designed specifically for use with Thermo Orion’s 260A and 265A pH meters. Sealed epoxy body with Ag/AgCl reference. Dimensions: 110 mm x 12 mm.

  • N 6480 Eth pH Electrode

    SI Analytics

    pH electrode for titrations in non-aqueous media, Glass shaft, ground joint-junction, electrolyte L 5034, Ag/AgCl-reference system, sphere membrane, A-glass, length 170 mm, 12 mm Ø, 0...+40 °C, 0...14 Ph

  • Minilab Waterproof ISFET pH Testers

    Hach

    …The non-glass, ISFET sensor stores dry and requires no maintenance. Sensor can be cleaned with a toothbrush and detergent. The Ag/AgCl reference electrode is replaceable. Two 3V lithium batteries provide 200 continuous hours of use. Low battery warning alerts user when there is only 10 hours…

  • General-Purpose pH Probe

    Oakton

    …to meet the needs of your application. Epoxy electrodes are impact resistant and provide exellent durability for field applications. Glass electrodes withstand aggressive chemicals. Choose junction and tip style based on the needs of your application. All electrodes feature Ag/AgCl reference cells.