GC

Compare Tool

Select up to 3 products

1 - 32 of 196
Sort
View
Show
  • Protect Your Investment - Hamilton guard columns protect analytical, semi-prep and preparative HPLC columns. They also remove particulate contaminants and highly adsorptive compounds from samples, prolonging column life. The designs are modular and cartridge replacement is easy and tool-free. …

  • Agilent Technologies

    Nitroterephthalic acid modified polyethylene glycol High polarity Designed for the analysis of volatile fatty acids and phenols Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 Temperature limits: 40° to 250°C NOTE: Agilent does…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Nitroterephthalic acid modified polyethylene glycol High polarity Temperature…

  • Agilent Technologies

    Unique selectivity engineered for optimum resolution of volatiles analysis: U.S. EPA Methods 502.2, 524.2 and 8260 0.45 mm ID columns provide more plates per meter compared to 0.53 mm ID columns for the fewest coelutions for GC method (an industry first)** No subambient cooling required to…

  • Agilent Technologies

    Bonded polystyrene-divinylbenzene based column A PLOT column with polarity between Porapak-Q and Porapak-N Column for C1 to C3 isomers and Alkanes to C12, CO2 , methane, air/CO, oxygenated compounds, sulfur compounds and solvents A PLOT column to replace packed…

  • The Hamilton silica replacement cartridge is suitable for use in normal phase separation mode.

  • quick-ship

    Agilent Technologies

    The Agilent Technologies accessory is used in HPLC (high-performance liquid chromatography) system, which is mainly used in biochemistry and analytical chemistry experiments to separate individual components from the mixture. This product is only available to U.S. Domestic Customers. For…

  • Agilent Technologies

    Least “polar” Alumina phase Aluminum oxide deactivated with KCl Good choice for light hydrocarbon analysis Good resolution of propadiene and butadiene from ethylene and propylene streams Similar Phases: CP-Al2O3/KCl PLOT, Rt-Alumina PLOT,…

  • Agilent Technologies

    Undeactivated tubing or bare fused silica is commonly used for capillary electrophoresis. It can also be used for transfer lines and other applications where inertness is not critical. Agilent Technologies products are intended for sale/shipment within the US only. International customers…

  • Agilent Technologies

    • New Bullet • New Bullet • New Bullet • New Bullet • New Bullet • New Text Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…

  • Hamilton PRP-X200 cation exchange HPLC columns are designed for rapid, high resolution separation of alkali and alkaline earth metals. The alkali metals and ammonium are completely resolved in less than five minutes, and the alkaline earth cations separate in under four minutes. Since the mobile…

  • Guard columns can provide many benefits when used upstream from an analytical, preparative, or semi-preparative column. Guard columns are typically chosen to have the same packing as the primary column. Any compounds or particulate material that would block the frits or highly adsorb to the primary…

  • Agilent Technologies

    50%-Cyanopropyl)-methylpolysiloxane High polarity Designed for separation of fatty acid methyl esters (FAMEs) Excellent resolution for cis- and trans-isomers Bonded and cross-linked Solvent rinsable Replaces HP-23 Close equivalent to USP Phase G5 Similar…

  • Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…

  • Polymeric cation exchange packing for separation of glyphosate and its metabolite in drinking water. Faster analysis when compared to competitor’s columns Detection levels of less than 10 ppb when using the post column, OPA derivatization technique Applicable to other…

  • Agilent Technologies

    Meets ASTM 6584 and EN14105 Standards 100% Dimethylpolysiloxane Non-polar Specially processed for extended temperature limit of 400°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Bonded and…

  • Agilent Technologies

    Bonded PLOT column technology Suitable for light hydrocarbons and sulfur gas Retention stability not affected by water Separates CO and CO2 on a single column Ideal PLOT column for CG/MS - no particles Temperature limits: -80° to 260°/300°C …

  • Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…

  • Agilent Technologies

    100% Dimethylpolysiloxane Identical selectivity to DB-1 Non-polar Very low bleed characteristics, ideal for GC/MS Improved acid performance compared to standard 100% Dimethylpolysiloxane columns Improved signal-to-noise ratio for better sensitivity and mass spectral integrity …

  • Agilent Technologies

    100% Dimethylpolysiloxane Industry standard general purpose column Non-polar Wide range of applications Superior performance of low molecular weight alcohols High temperature limit Bonded and cross-linked Solvent rinsable Wide range of column dimensions …

  • These are capillaries with a window and 75 cm effective length and 363 µm od, fitting into any CE instrument. To cut them to the correct length we recommend using the 2714T16 CE column cutter. Agilent Technologies products are intended for sale/shipment within the US only. International…

  • Agilent Technologies

    SE-30: 100% Dimethylpolysiloxane SE-54: (5%-Phenyl)(1%-Vinyl)-methylpolysiloxane Because SE series GC columns are not bonded or cross-linked, we do not recommend solvent rinsing. Agilent Technologies products are intended for sale/shipment within the US only. International customers…

  • Agilent Technologies

    30% heptakis (2,3-di-O-methyl-6-O-t-butyl dimethylsilyl)-β -cyclodextrin in DB-1701 Chiral separations without chiral specific derivatization New stationary phase for improved resolution of many chiral separations Suitable for many chiral γ -lactones and terpenes Similar…

  • Agilent Technologies

    Specifically designed for the analysis of chlorinated pesticides and PCBs U.S. EPA Methods: 608, 508, 8080 Excellent inertness and recoveries without pesticide breakdown Bonded and cross-linked Solvent rinsable Exact replacement of HP-608 Similar Phases: SPB-608,…

  • Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-5 (2713R99, T86, T94 and V89) (5%-Phenyl)-methylpolysiloxane Non-polar …

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Non-polar Excellent general purpose column …

  • Agilent Technologies

    10.5% Beta-Cyclodextrin in DB-1701 Chiral separations without chiral specific derivatization Broad range of resolving potential Excellent peak shape Similar Phases: LIPODEX C, Rt-β DEXm, β -DEX 110, β -DEX 120 Because Cyclodex-B GC columns are not bonded or cross-linked,…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Identical selectivity to HP-1 Non-polar Low…

  • Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…

  • Agilent Technologies

    (50%-Cyanopropylphenyl)-dimethylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Bonded and cross-linked Solvent rinsable Exact replacement of HP-225 Close equivalent to USP Phase G7 Similar Phases:…

Compare Tool

Select up to 3 products