Restek, Nucleic Acid
-
Roc HPLC columns are built to be the cornerstone for your LC lab. These solid, reliable columns are pressure rated for any 400 bar HPLC system and deliver the peak shape, reproducibility, ruggedness, and performance you demand for all of your conventional HPLC applications. An exceptional value,…
-
permethylated beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to columns that have pure…
-
low- to midpolarity phase; Crossbond diphenyl dimethyl polysiloxane Rtx-20 polymer is synthesized to exacting standards. All residual catalysts and low molecular weight fragments are removed from the polymer, providing a tight monomodal distribution and extremely low bleed. …
-
Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or “core-shell” particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and…
-
5% diphenyl, 95% dimethyl polysiloxane Optimized for PBDE analysis by EPA Method 1614. Short column option resolves BDE-209 3 times faster, with less thermal breakdown. Unique deactivation gives higher BDE-209 response than competitor columns, for greater analytical sensitivity. …
-
3x faster multiresidue pesticides analysis in foods. Factory-coupled, leak-free kit makes setting up LPGC as simple as a column change. Ideal for speeding up GC-MS and GC-MS/MS methods. Integrated transfer line reduces background and stabilization time.
-
Ultra Carbamate Columns
RestekRestek chemists developed the Ultra Carbamate column specifically for carbamates analysis. The unique packing separates 10 target carbamates in just 5 minutes with an 8 minute total cycle time. The column is compatible with fluorescence or LC-MS detection.* An Ultra Carbamate column can process as…
-
100% divinylbenzene Porous polymers are unique, highly retentive stationary phases with a wide application range that are able to elute both polar and nonpolar compounds. They are very hydrophobic, so water has no impact on retention times and even elutes as a good chromatographic peak. The…
-
midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane Column specifically tested for low-bleed performance. Rtx-200 columns have accomplished many difficult separations not possible on any other bonded stationary phase. Many analysts consider these the best, most inert midpolarity…
-
Micropacked GC Columns
RestekIncreased efficiency over traditional packed columns. Higher capacity than PLOT columns. Made from inert, flexible SilcoSmooth tubing. Wide range of packings available. Standard coils fit all instruments. No special instrument configurations required. Efficient, Inert, and…
-
polar polyethylene glycol deactivation Tested with a comprehensive test mix to ensure high inertness Polyethylene glycol deactivation layer provides optimum wettability for polar compounds Minimize peak splitting when using polar solvents such as methanol or water Compatible with…
-
PLOT Column Particle Trap
RestekThe technology used to adhere particles in PLOT columns is excellent; however, it is still possible for particles to dislodge when extreme pressure shocks and gas flow changes occur. This sometimes happens when valve switching or backflushing is used. In those cases, using particle traps is…
-
Useful for a wide range of applications Compatible with most common solvents Maximum temperature: 325°C
-
Restek’s molecular sieve 5A PLOT columns are designed for efficient separation of argon/oxygen and other permanent gases, including carbon monoxide. Special coating and deactivation procedures ensure chromatographic efficiency and the integrity of the porous layer coating. Molecular sieves…
-
proprietary Crossbond diphenyl/dimethyl polysiloxane phase An Rtx-502.2 column will enable you to quantify all compounds listed in U.S. EPA methods 502.2 or 524.2, whether you use a mass spectrometer or a PID in tandem with an ELCD. The diphenyl/dimethyl polysiloxane based Rtx-502.2 stationary…
-
Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or “core-shell” particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and…
-
polar phase; Crossbond polyethylene glycol The elution order of polyunsaturated FAMEs on FAMEWAX columns is comparable to that on other Carbowax columns, but baseline resolution is achieved in significantly less time. Application-specific columns for FAMEs, specially tested with a FAME…
-
2,3-di-acetoxy-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to…
-
Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or “core-shell” particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and…
-
low-polarity phase; Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to…
-
Advantages of metal MXT PLOT columns include: Can be made in small coil diameters—perfect for tight spaces. Rugged material withstands rough handling and shock. Designed for robust performance in process GCs and field instruments. Available in 3.5"-coil diameter or…
-
Accurate quantification of toluene and benzene—including benzene in gasoline containing ethanol or butanol blends. Complete resolution of benzene from ethanol—no compromising coelutions. Enhanced formulation with improved support material and polymers—more robust and reproducible. Column sets…
-
High-quality, silica-based hydrophilic adsorbents. Used for common sample matrices such as food, soil, and water. SAX – strong anion exchange. Stable over the pH range (2 – 9).
-
Fast analysis times and sharp mono-, di-, and triglyceride peaks. Stable at 430°C for reliable, consistent performance.
-
low- to midpolarity phase Many analysts feel the Rtx-1301 column has the best cyanosiloxane bonded stationary phase available, with no other column manufacturer providing lower bleed, longer lifetime, or better inertness. Our polymer is fully characterized to ensure long-term reproducibility,…
-
Ultra Quat Columns
RestekA retentive, high-purity, base-deactivated, reversed-phase packing. Ideal for the analysis of paraquat and diquat or other quaternary amines. Particle Size: 3 µm or 5 µm, spherical Pore Size: 100 Å pH Range: 2.5 to 8 Temperature Limit: 80°C
-
high-polarity phase; Crossbond diphenyl dimethyl polysiloxane The Rtx-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number. Because of the chemistry required to achieve 370°C thermal stability, an Rtx-65TG column should not be used for the analyses of…
-
Porous Polymer Columns
RestekRestek offers a full range of porous polymers, including HayeSep and Porapak polymer packings for analyses of volatile compounds and light solvents.
-
low- to midpolarity phase The unique polarity of the Rtx-624 column makes it ideal for analyzing volatile organic pollutants. Although the Rtx-502.2 column is recommended in many methods, the Rtx-624 column offers better resolution of early eluting compounds. The Rtx-624 phase produces greater…
-
Developed specifically for challenging analyses of polycyclic aromatic hydrocarbons (PAHs). The Pinnacle II PAH stationary phase incorporates a proprietary C18 bonding that enables unique shape selectivity to baseline-resolve all 16 PAHs listed in U.S. EPA Method 610 plus two other routinely…