Restek, Nucleic Acid
-
Tested with a comprehensive test mix to ensure high inertness. Useful for a wide range of applications. Use with most common solvents. Maximum temperature: 325°C. *30- and 60-meter lengths are banded in 5-meter sections. †Recommendation: Cut 60 m guard columns into shorter…
-
Viva HPLC Columns: 3 or 5 µm particles; 300 Å pore size Excellent for separating peptides or proteins Rugged, spherical particles with 300 Å pore size High proportion of pore/surface area available to large molecules Viva columns are based on a wide pore material…
-
Roc HPLC columns are built to be the cornerstone for your LC lab. These solid, reliable columns are pressure rated for any 400 bar HPLC system and deliver the peak shape, reproducibility, ruggedness, and performance you demand for all of your conventional HPLC applications. An exceptional value,…
-
high-polarity phase; Crossbond diphenyl dimethyl polysiloxane The Rtx-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number. Because of the chemistry required to achieve 370°C thermal stability, an Rtx-65TG column should not be used for the analyses of…
-
proprietary Crossbond phase Improved resolution and faster analyses, compared to 1701 or phenyl phases, make these the pesticide columns of choice. Rtx-CLPesticides columns are specially designed to overcome the coelutions and analyte breakdown typically encountered in chlorinated pesticide…
-
Fast analysis times and sharp mono-, di-, and triglyceride peaks. Stable at 430°C for reliable, consistent performance.
-
polar polyethylene glycol deactivation Tested with a comprehensive test mix to ensure high inertness Polyethylene glycol deactivation layer provides optimum wettability for polar compounds Minimize peak splitting when using polar solvents such as methanol or water Compatible with…
-
Viva HPLC Columns: 3 or 5 µm particles; 300 Å pore size Excellent for separating peptides or proteins Rugged, spherical particles with 300 Å pore size High proportion of pore/surface area available to large molecules Viva columns are based on a wide pore material…
-
low- to midpolarity phase The unique polarity of the Rtx-624 column makes it ideal for analyzing volatile organic pollutants. Although the Rtx-502.2 column is recommended in many methods, the Rtx-624 column offers better resolution of early eluting compounds. The Rtx-624 phase produces greater…
-
low-polarity phase; Crossbond diphenyl dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this…
-
midpolarity phase; Crossbond diphenyl dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this…
-
Linearity for all reference compounds exceeds method requirements. Columns with retention gaps feature Alumaseal connectors to prevent leaks and extend column life. Low column bleed at high temperatures. For glycerin and glycerides analysis, according to ASTM D6584 and EN 14105 methods. …
-
Allure Acrylamide
RestekParticle: 5 μm, spherical Pore Size: 60 Å Carbon Load: proprietary End-cap: no Surface Area: 450 m 2 /g pH Range: 2.5 to 8 Maximum Temperature: 80 °C
-
Allure Organic Acids Columns
RestekAllure Organic Acids columns provide enhanced retention and selectivity for polar organic acids, allowing the separation to be performed on a single 30 cm column. An Allure Organic Acids column effectively resolves key organic acids such as tartaric and quinic acids using the chromatographic…
-
Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or “core-shell” particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and…
-
Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or “core-shell” particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and…
-
Roc HPLC columns are built to be the cornerstone for your LC lab. These solid, reliable columns are pressure rated for any 400 bar HPLC system and deliver the peak shape, reproducibility, ruggedness, and performance you demand for all of your conventional HPLC applications. An exceptional value,…
-
CarboBlack Packing Materials
RestekCarboBlack B supports up to 10% loading of a nonsilicone liquid phase CarboBlack C supports up to 1% loading of a nonsilicone liquid phase Graphitized carbon black offers unique selectivity and very little adsorption for alcohol analyses. Two types of CarboBlack supports are available,…
-
Rxi-65TG Cap. Columns
RestekIdeal for the analysis of triglycerides in edible oils Excellent thermal stability up to 370 °C ensures consistent results and longer column lifetimes Separate and quantify critical triglycerides (acylglycerols) without interference from column bleed Observe even underivatized mono- and…
-
2,3-di-O-methyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to…
-
low-polarity phase; Crossbond diphenyl dimethyl polysiloxane The diphenyl dimethyl polysiloxane stationary phase is the most popular GC stationary phase and is used in a wide variety of applications. All residual catalysts and low molecular weight fragments are removed from the MXT-5 polymer,…
-
100% divinylbenzene Porous polymers are unique, highly retentive stationary phases with a wide application range that are able to elute both polar and nonpolar compounds. They are very hydrophobic, so water has no impact on retention times and even elutes as a good chromatographic peak. The…
-
Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or “core-shell” particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and…
-
midpolarity Crossbond phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…
-
nonpolar phase; Crossbond dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of…
-
These application-specific columns for blood alcohol analysis baseline separate all critical compounds—including ethanol, methanol, acetone, tert-butanol, acetaldehyde, isopropanol, and n-propanol—in less than 2 minutes. Every Rtx-BAC Plus 1 and Rtx-BAC Plus 2 column is qualified with a…
-
low- to midpolarity phase Many analysts feel the Rtx-1301 column has the best cyanosiloxane bonded stationary phase available, with no other column manufacturer providing lower bleed, longer lifetime, or better inertness. Our polymer is fully characterized to ensure long-term reproducibility,…
-
low- to midpolarity phase General-purpose columns for residual solvents, alcohols, oxygenates, and volatile organic compounds. Temperature range: -20°C to 280°C. Equivalent to USP G43 phase. 4.5" standard coil diameter.
-
Capable of both reversed-phase and HILIC separations Ideal for increasing sensitivity and selectivity in LC-MS analyses Offers increased retention for charged bases Similar Phase(s): Discovery HS F5, Luna PFP(2), Pursuit PFP, Acquity UPLC HSS PFP, Hypersil Gold PFP, Titan PFP (1.9…
-
High-quality, silica-based hydrophobic adsorbents. Used for common sample matrices such as food, soil, and water. Ideal when less retention than a C18 is needed. Stable over the pH range (2 – 8).
-
nonpolar phase; Crossbond 100% dimethyl polysiloxane—for simulated distillation MXT-2887 columns' stationary phase, column dimensions, and film thicknesses have been optimized to exceed the resolution and skewing factor requirements specified in ASTM Method D2887. Each column is…
-
midpolarity phase; Crossbond phenyl methyl polysiloxane General-purpose columns for pesticides, herbicides, rosin acids, phthalate esters, and sterols. Temperature range: 0°C to 300°C. Equivalent to USP G3 phase. 4.5" standard coil diameter.