PerkinElmer, Nucleic Acid Sample Preparation
-
The Brownlee Spheri line of columns is based on a small-pore (80 Angstrom ) silica-based sorbent for optimized for separating small molecules. Spheri-5 ® columns are based on 5 m particle size silica and Spheri-10 ® incorporates a 10 m silica particle. Spheri-5 columns are available in both…
-
Elite-1 capillary column, 105m x 0.45mm, 2.55µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Temperature range -60oC to 200 oC
-
Elite-1 capillary column, 15m x 0.32mm, 3.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Supra-Clean Strong Anion Exchange (SAX) Solid Phase Extraction (SPE) products are for extracting acidic compounds.
-
Elite-5ht capillary column 30m x 0.25mm, 0.10µm
PerkinElmerTemperature range -60 o C to 400 o C. Equivalent to USP G27, G36 phases.
-
PerkinElmer pioneered the development of Fast HPLC and introduced the popular 3 m particle size “3 x 3” Columns (33 mm x 4.6 mm) in the 1980s. The “3 x 3” columns are capable of very rapid analysis and still they are still very popular in many laboratories because of the economical price and…
-
-
PerkinElmer pioneered the development of Fast HPLC and introduced the popular 3 m particle size “3 x 3” Columns (33 mm x 4.6 mm) in the 1980s. The “3 x 3” columns are capable of very rapid analysis and still they are still very popular in many laboratories because of the economical price and…
-
Elite-1ht capillary column 30m x 0.25mm, 0.10µm
PerkinElmerTemperature range -60 o C to 400 o C. Equivalent to USP G1, G2, G38 phase.s.
-
Brownlee Polypore is a polymer based hydrogen form (microporous 10um) sorbent for the analysis of organic acids and sugars. Requires holder P/N 07150013 without guard column. If a guard column is being used P/N 07150018 and P/N 07150002 will also be required.
-
3 cm PECO Column Holder
PerkinElmerNewGuard cartridges are small guard cartridges (15 mm x 3.2 mm ID) packed with 5 or 7 µm sorbents. They help to prolong column life by eliminating particulates, contaminants, and strongly bound sample components; acting as replaceable disposable heads of your analytical column. There is negligible…
-
-
Brownlee SPP 2.7 mm C18 4.6 X 100 mm
PerkinElmerFeatures and Benefits Solid inner core, porous silica outer shell, shorter diffusion path Very high efficiencies at moderate back pressures Nearly twice the efficiency of 3-mm particle columns As robust as columns packed with 5-mm particles because columns use 2-mm frits Can exceed…
-
Elite-WAX capillary column 15m x 0.45mm, 0.42µm
PerkinElmerTemperature range 20oC to 250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
-
Brownlee Spheri-10 RP-18 (C18) is based on a small pore silica, monofunctional, optimized for separating small molecules. Requires holder P/N 07150014 without guard column or P/N 07150016 with a guard column.
-
Elite-1 capillary column, 15m x 0.25mm, 1.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite-200 capillary column 30m x 0.32mm, 0.25µm
PerkinElmerEquivalent to USP G6 phase. Temperature range -20°C to 320/340°C.
-
Glass Empty Column, 2mm i.d., 1/4in o.d., 3 ft for AutoSystem GC (on column)
-
Elite-502.2 Columns are fused silica columns are for analysis of volatiles with EPA 502.2
-
Temperature range -60°C to 300/315°C.
-
COL-Elite 1 30 m, 0.25 mm ID, 0.25
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Brownlee Polypore is a polymer based hydrogen form (microporous 10um) sorbent for the analysis of organic acids and sugars. Requires holder P/N 07150014 without guard column or P/N 07150016 with a guard column.
-
-
Elite-1 capillary column, 30m x 0.53mm, 1.50µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Polyimide Uncoated Deactivated Fused Silica Capillary Tubing comes in a standard length of 5 meters.
-
Brownlee Aquapore C8 columns are based on wide pore 300 7µm silica, for the analysis of large bio-molecules. Requires holder P/N 07150013 without guard column. If a guard column is being used P/N 07150018 and P/N 07150002 will also be required.
-
Deactivated Tubing is perfect for making guard columns and retention gaps. Use Splitters(p/n N9303448) and connectors (p/n N9302149) to attach tubing to polymide coated columns.
-
SPE Supra-CleanC18-S Column, 500 mg/3 mL
PerkinElmerC18-S Supra-CleanSpherical Silica-based Solid Phase Extraction (SPE) Columns are recommended for extracting mid-polar to non-polar compounds when analyzing drugs and drug metabolites in biological matrices, trace organic material in water, and toxins in food. SPE Format: Straight PP TubeMedia…
-
SPE Supra-Clean C18-S Column, 2 g/15 mL
PerkinElmerC18-S Supra-Clean® Spherical Silica-based Solid Phase Extraction (SPE) Columns are recommended for extracting mid-polar to non-polar compounds when analyzing drugs and drug metabolites in biological matrices, trace organic material in water, and toxins in food. SPE Format: Straight PP Tube …
-
Overview: Sample preparation is arguably the most critical step within the analytical process. Studies have reported that sample preparation can represent up to 60 % of a laboratory technicians timetable and also forms one of the principal sources of error. Sample preparation undoubtedly has a…