PerkinElmer Lab Supplies
-
Fume Hood for SPB 50-24, 50-48, 100-12, 100-30
PerkinElmerThe bench top fume hoods for SPB systems are the right choice for trace-metal digestions. Made from clear, acid resistant polycarbonate with a solid surface material base, the fume hood eliminates the risk of trace-metal contamination common with traditional fume hoods. HEPA ® filters ensure clean…
-
Manganese (Mn) Atomax Hollow Cathode Lamp
PerkinElmerSingle Element Atomax hollow cathode lamp (HCL) for the detection of elemental Manganese (Mn). PerkinElmer Atomax 1.5"" hollow cathode lamps are crafted to the same high standards that have made our 2"" Lumina ™ hollow cathode lamps the best in the industry. Drawing on more than 40 years of HCL…
-
Ultra quiet for use in the laboratory area Compact size and light weigh Commercial / Industrial grade1 Year warranty on workmanship 5. 0 micron pre-filter and regulator Internally powder coated air tank to prevent rust Pressure switch for automatic operation 1 year warranty Horse Power: 0. 60 …
-
PEEK Sample Loops avoid many of the problems associated with stainless steel sample loops. Metal loops will often absorb sample components resulting in inaccurate quantitative results. In addition, metal loops may be corroded by high-salt buffers and chloride salts. Sample Loops are made from PEEK…
-
Each product is manufactured using strict quality control standards resulting in consistent cap dimensions with septa which may be certified for higher purity grades. All our caps and septa are packed in a clean environment to ensure you receive contaminant free product every time. PerkinElmer…
-
200µL Sample Loops
PerkinElmerTubing Adapters and Connectors provide a means to connect the component shown to the screw fittings of the PTFE tubing assemblies or to connect the tubing components described.
-
Stainless Steel High Pressure Capsules
PerkinElmerIncludes 5 stainless steel capsules and 20 gold-plated copper seals. For DSC runs where high pressure is expected in the capsule, we recommend you use high pressure capsules. The capsules are safe to handle due to a bursting disk on the cover of the capsule which allows the sample to escape if the…
-
Pump Priming Syringe
PerkinElmerThe PerkinElmer pump priming syringe with a volume capacity of 30 mL has a strong plastic construction and is used in chemical laboratories.
-
This PTFE-coated Viton o-ring, with an inner diameter of 6.07 mm and width of 1.78 mm, is used for the internal injector support adapter with ELAN 6000, 9000, DRC II, and DRC-e, and NexION 300 and 350 ICP-MS series instruments.
-
Glass Chamber with 12 Positions
PerkinElmerSPE Vacuum Manifolds accommodate either 12 or 24 cartridges; 1, 3, 6, 15 and 25 mL columns can be used. Manifolds are equipped with a vacuum port to connect a standard laboratory vacuum pump. Vacuum pulls the sample through the stationary phase, metered by the stopcocks, to control the speed of…
-
Concentration: 1,000 µg/mL Matrix: 10% HCI Volume: 125 mL Features and Benefits Pure Grade Standards for AA and ICP-OES Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final solution and reported on the certificate Impurities reported…
-
Spring loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no need for loosening and tightening fittings every time a trap is changed and your system will not become contaminated during the process.
-
The 32 cm PTFE drain line has a 1/4-28 spray chamber fitting. 160 cm of additional 0.8 mm I.D. drain line tubing is included.
-
PTFE connecting tube for connection to digestion vessels with 8 and 16 position Gas Containment Manifold.
-
Temperature range 40°C to 360°C Equivalent to USP G3
-
0.15MM ALUMINIUM COVERS
PerkinElmerThe Autosampler sample pans are used to prepare sample materials for the Pyris 1 Autosampler, DSC 7 RS and DSC-4 RS. Pans are available in sealed or vented versions. These pans may also be used for non-robotic systems. Sealed. 1 bar maximum internal pressure. Require Covers (B0143003). Can be used…
-
Leybonol Fomblin GV80 Fluid
PerkinElmerThe Leybonol Fomblin GV80 1 Liter fluid and can be used with any type of ultra-clean vacuum systems.
-
The Autosampler sample pans are used to prepare sample materials for the Pyris 1 Autosampler, DSC 7 RS and DSC-4 RS. Pans are available in sealed or vented versions. These pans may also be used for non-robotic systems. Sealed. 1 bar maximum internal pressure. Require Covers (B0143003). Can be used…
-
Multi-Element Lumina hollow cathode lamp (HCL) for the detection of elemental Aluminum (Al), Calcium (Ca), and Magnesium (Mg). Please note that multi-element lamps are not designed to be used in a furnace system. Every genuine PerkinElmer lamp is designed for use with and tested on PerkinElmer…
-
20 mm Hand Crimper
PerkinElmerFor use on GC Headspace Vials or LC Large Volume Vials. Crimp capping is still a preferred method by some laboratories to ensure sample integrity, particularly those containing volatile compounds.
-
Elite-1 capillary column, 60m x 0.32mm, 1.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
The 5 cm nitrous oxide burner head is required for nitrous oxide-acetylene operation. This burner head can also be used with air-acetylene or rotated to provide reduced sensitivity.
-
Manual Hand Crimper
PerkinElmerThe PerkinElmer manual hand crimper with an inside diameter of 8 mm is used in chemical laboratories.
-
-
PYRIS 1 TGA Autosampler Quartz Hanger Kit
PerkinElmerPYRIS 1 TGA Autosampler Quartz Hanger Kit, pkg 5
-
-
The Silicon (Si) Metallo-Organic Standard is available from PerkinElmer and ideal for an array of ICP-MS applications.
-
Sampling Syringe
PerkinElmerThe PerkinElmer 500 uL sampling syringe is useful for taking liquid samples in laboratories and factories.
-
Silver (Ag) Lumina Hollow Cathode Lamp
PerkinElmerSingle Element Lumina hollow cathode lamp (HCL) for the detection of elemental Silver (Ag). Every genuine PerkinElmer lamp is designed for use with and tested on PerkinElmer spectrometers to assure compatibility and the highest performance. PerkinElmer offers a wide range of single-element and…
-
The SeaSpray Concentric Nebulizer is ideal for samples with high dissolved solids and offers outstanding nebulization effciency for trace level analysis. It offers freedom from clogging while nebulizing solutions near the limit of solubility of most mineral salts, and conferring signifcant…
-
The UniFit connector is a convenient drain connector for glass cyclonic spray chambers.
-
Elite-1 capillary column 60m x 0.32mm, 1.50µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases. Temperature range -60°C to 310/330°C.