  • These vials require a special cap with an 18 mm thread. The standard 18-400 threaded caps will not fit this vial. The part numbers for caps that are available for these vials are SU860101(with PTFE/silicone, 1.3 mm thick), SU860102 (with PTFE/butyl, 1.6 mm thick), and SU860103 (with PTFE/silicone,…

  • MilliporeSigma

    Economical and convenient storage for samples in your screw cap and crimp seal vials. Can be stacked when empty or full. Autoclavable, 120C. Each case contains 5 racks. Synonyms: VIAL RACK,40ML EPA VIAL, 5/CS Legal Information: WHEATON is a registered trademark of Wheaton Industries, Inc.

  • The BiMetal caps are made of both tin and aluminum and are easier to crimp than tin 20mm seals. The sealing surface is aluminum and the inner diameter is made of tin to add the magnetic surface. These caps are available in a variety of colors. Other Notes: We recommend using the plier-type…

  • Caps have white styrene-butadiene rubber liner and are packed in Lab-File® cases. Clear Wheaton-33, low extractable borosilicate glass or amber Wheaton-320 glass. Can be sterilized and stored at low temperatures. Legal Information: Lab File is a registered trademark of Wheaton Industries, Inc.

  • Insert fits 12 x 32 mm vials with large opening (6.0 mm)

  • The QSertVial(TM) is the ultimate microsampling device. It contains a 300 muL glass insert that is fused to the vial to form one precise integral unit. The rim of the insert is positioned slightly above the top of the vial so the septum can make a secure seal with the closure, eliminating…

  • PTFE/Silicone is recommended for use with most organic solvents until PTFE is pierced. It has good resealability and can withstand a temperature of 250C.

  • These autoclavable caps are designed to ensure the ultimate in product safety.

  • MilliporeSigma

    Vials, screw top (4mL) are mainly used to inject samples from an autosampler. Autosampler needle pierces through the cap during injection and withdraws the required aliquots of sample from the vials.

  • MilliporeSigma

    Short thread screw cap, 9 mm thread, with liner are suitable for use with short thread (11.6 X 32 mm) autosampler vials (9 mm thread). The PTFE/rubber septa are compatible with most organic solvents until pierced and are not recommended for aromatics, carbon disulfides, chlorinated solvents,…

  • Insert fits 12 x 32 mm vials with large opening (6.0 mm) Application: It may be used to contain albumin standard solution in an absolute quantification method like protein hydrolysis, o-phthalaldehyde derivatization, and reversed-phase high-performance liquid chromatography analysis in a…

  • MilliporeSigma

    The Supelco hand held crimper provides a consistent and dependable seal that allows secure vial closure each and evey time. The high quality construction is engineered for durability and long life to provide a smooth and simple operation.

  • MilliporeSigma

    Screw caps (black phenolic hole cap, for use with 20 or 40 mL vial with 24-400 thread) are available as hole caps for use with sealing septa. Caps are offered in phenolic resin. Phenolic hole caps can withstand a maximum temperature of 149C.

  • Each of the vials is cleaned according to US EPA Protocol B: The cleaning procedure is as follows: 1. Wash containers in hot water using laboratory grade non-phosphate detergent 2. Rinse three times with copious amounts of tap water to remove detergent 3. Rinse three times with ASTM Type I…

  • Each of the vials is cleaned according to US EPA Protocol B: The cleaning procedure is as follows:1. Wash containers in hot water using laboratory grade non-phosphate detergent.2. Rinse three times with copious amounts of tap water to remove detergent.3. Rinse three times with ASTM Type I…

  • Vial inserts basically permit the use of smaller sample volumes with standard autosampler vials. Inserts are generally chosen based on the inner diameter of the vial neck. Standard opening vials (4.6 mm ID) require a 5 mm OD insert.

  • MilliporeSigma

    Vial septa are available in a variety of materials. Septa, tan PTFE/silicone (diam. x thickness 8 mm x 1.5 mm) are sized to fit screw top vials. They are suitable for use with most organics (until pierced) and are not recommended for use with chlorosilanes.

  • Supelco's new Low Adsorption (LA) vials are manufactured using a process that decreases the number of hydroxyl groups on the vial's glass surface, significantly reducing surface activity while improving analytical quantitation and minimizing pH shifts in the sample. This same process also removes…

  • Reliable Wheaton "180" brand low-potassium glass. White 22 mm caps have tops suitable for writing. Vials with caps attached are packed in individual cells in trays of 100.

  • MilliporeSigma

    Application: Septa may be used in headspace solid-phase microextraction (SPME) (lyophilized aqueous extract).

  • Each of the vials is cleaned according to US EPA Protocol B: The cleaning procedure is as follows:1. Wash containers in hot water using laboratory grade non-phosphate detergent.2. Rinse three times with copious amounts of tap water to remove detergent.3. Rinse three times with ASTM Type I…

  • MilliporeSigma

    Storage bottles are generally used to store stock solutions and other chemicals. Amber bottles are used to avoid oxidative changes in photosensitive chemicals. Synonyms: SCREW-CAP AMBER SEPTUM BOTTLE 240ML PK12

  • MilliporeSigma

    Green Thermoset Plastic Caps with F-217 PTFE Liners are known for providing the widest range of chemical compatibility and for being the most temperature tolerant of plastic closures. The color green easily identifies the PTFE liner system. F-217 foam-backed PTFE liners resist attack from virtually…

  • Other Notes: The inside diameter of vials vary with the manufacture. The following insert part numbers are compatible with these large opening vials. •29435-U PK100, Certified 200 muL glass inserts, mandrel precision point, 6 X 29mm, with bottom spring •29436-U PK100, Certified 250 muL glass…

  • MilliporeSigma

    Other Notes: Large opening inserts fits crimp seal, snap ring, and 9 mm threaded vials (with 6.0 mm ID)

  • MilliporeSigma

    Micro volume vial inserts, when used in conjunction with autosampler vials, allow for maximum sample recovery and easier sample removal. Vial inserts allow the use of smaller sample volumes with standard autosampler vials. Inserts should be chosen based on the inner diameter of the vial neck. …

  • MilliporeSigma

    Application: Septa, tan PTFE/silicone has been used to seal the reactivial containing the by-product sample of snow crab, which is subjected to alkaline liquid phase hydrolysis. Legal Information: Tenax is a registered trademark of Buchem B.V.

  • Other Notes: The inside diameter of vials vary with the manufacture. The following insert part numbers are compatible with these large opening vials. •29435-U PK100, Certified 200 muL glass inserts, mandrel precision point, 6 X 29mm, with bottom spring •29436-U PK100, Certified 250 muL glass…

  • MilliporeSigma

    Vials, clear glass (1.5mL) are suitable basically to inject samples from an autosampler. Autosampler needle pierces through the cap during injection and withdraws the required aliquots of sample from the vials.

  • Vial inserts allow the use of smaller sample volumes with standard autosampler vials. Inserts are generally chosen based on the inner diameter of the vial neck. Standard opening vials (4.6 mm ID) require a 5 mm OD insert.

  • This vial is designed to work in the Waters WISP(TM) 96 Position Autosampler. Avialable in clear Type 1 borosilicate glass. Vials feature thicker walls for safer sample handling. Please order your closure separately. Legal Information: Waters is a registered trademark of Waters