Hamilton, Supplies

Compare Tool

Select up to 3 products

1 - 32 of 1175
Sort
View
Show
  • Hamilton

    The Hamilton gel caddy measuring 30 cm x 40 cm is sold as 50 per pack.

  • 1700 series, gastight syringes with cemented needles. Length: 1.71 23s-26s gauge AS Point Style

  • The Microlab 600 Stand Alone Syringe Pump is available as a single syringe system. The pump ships with a Universal Valve(s), country specific Power Cord, Custom Programmer Kit and the choice of syringes. If a syringe is not selected at the time of the order a 1 mL syringe will be included…

  • The Small Hub Removable Needle (RN) is compatible with RN syringes from 2.5 µL to 100 µL. Needles are available from 34 to 18 gauge. All needles are sold in six-packs and the standard needles are 51 mm long. For all custom needles, the length and point style will need to be specified prior to…

  • Hamilton

    Hamilton pipette tips are universal-fit. Hamilton SoftGrip™ Manual Pipettes are used with Hamilton AdvanTip Pipette Tips deliver outstanding accuracy and precision, guaranteed.

  • Volume 2.5 mL Syringe Type Gastight Syringe Series 1000 Termination PTFE Luer Lock (TLL) Needle Metal (N) or Kel-F Gauge No Needle Included Point Style No Needle Included Needle Length No Needle Included …

  • Hamilton

    The Hamilton 700 series 10 uL syringe is suitable for use with small removable needles. This syringe model offers SST and borosilicate glass fluid path. It can be used at a pressure rating of up to 2000 psig and temperature rating of up to 10 to 115 degree C.

  • Removable needles Length: 1.71” HP point style See 8928C31 series for replacement needles.

  • Guard columns can provide many benefits when used upstream from an analytical, preparative, or semi-preparative column. Guard columns are typically chosen to have the same packing as the primary column. Any compounds or particulate material that would block the frits or highly adsorb to the primary…

  • The Hamilton barrel is suitable for use with 10 mL 1010TLL syringe models.

  • Hamilton

    The Hamilton 1000 series 50 mL syringe is suitable for use with metal (N) or kel-F needles. This syringe model offers borosilicate glass, PTFE and PCTFE fluid path. It can be used at a pressure rating of up to 100 psig and temperature rating of up to 10 to 80 degree C.

  • Hamilton

    The Hamilton 12 gauge flanged tubing enables to quickly connect and disconnect different components in the laboratory. It is suitable for use with luer lock conversion kit. With washer

  • Gauge: 25s Length: 1.97” Point style: 3 Syringes feature removable needles; Teflon ® PTFE-tipped plungers. Barrel, plunger and plunger tip are replaceable. 1800 Series has adjustable friction, which controls plunger resistance, and plunger stop helps prevent blow-out. …

  • Length: 2” Point style: 3 For use with Rheodyne, Valco™ VISF-2, Beckman®/Altex and SSI injection valves. Syringes are available with cemented or removable needles and feature Teflon® PTFE-tipped plungers. Barrel, plunger and plunger tip are replaceable. See…

  • Hamilton 84303 CR-700 50µL CR700-50 Constant Rate HPLC Syringe with 22g x 2" x PT3 Needle has preset volumes that can be dispensed at a constant flow rate. The volume is adjustable with a precise adjustable micrometer screw. The adjusted volume can be fixed with a locking ring.…

  • Hamilton

    The Hamilton battery door is suitable for use with digital syringe models.

  • Hamilton

    The Hamilton 1800 series 10 uL syringe is suitable for use with small removable needles. This syringe model offers SST, borosilicate glass and PTFE fluid path. It can be used at a pressure rating of up to 1000 psig (68.9 bar) and temperature rating of up to 10 to 115 degree C.

  • The Hamilton replacement plunger assembly is suitable for use with 500 uL CTC syringe models.

  • Guard columns can provide many benefits when used upstream from an analytical, preparative, or semi-preparative column. Guard columns are typically chosen to have the same packing as the primary column. Any compounds or particulate material that would block the frits or highly adsorb to the primary…

  • These adapters are designed to attach to the end of standard Hamilton syringes to modify the functionality of the syringe. The Septum adapter connects to the end of TLL and LT syringes and can be used for sample spiking. The MTB sampling valve also connects to the ends of a TLL or LT syringes to…

  • Hamilton

    The Hamilton 1700 series 250 uL syringe features luer tip termination. It is suitable for use cemented needles. This syringe model offers SST, borosilicate glass and PTFE fluid path. It can be used at a pressure rating of up to 500 psig and temperature rating of up to 10 to 50 degree C.

  • Hamilton

    The PRP-h5 derives its hydrophobic functionality from a pentafluorinated polymer bead, delivering a selectivity difference from standard silica C18 stationary phases. This gives chromatographers the desired retention characteristics necessary for certain sample types. This difference is especially…

  • Hamilton offers a diverse line of inert fittings and connectors made from CTFE. The fittings are designed for use with industry-standard Luer and Luer lock products like our syringes as well as threaded 1/4"-28 and M6 flat bottom ports.

  • The Hamilton replacement plunger tip is suitable for use with CR-700-50 constant rate syringe models.

  • The ML500 tubing assemblies are manufactured using thick walled FEP tubing. The thick walled tubing is desirable because it resists kinking during the rigors of the workday. The 12 gauge tubing has a larger inner diameter and should be used with syringe sizes larger than 2.5 mL or with viscous…

  • Hamilton

    The Hamilton 1000 series 10 mL syringe is suitable for use with large removable needles. This syringe model offers SST, borosilicate glass and PTFE fluid path. It can be used at a pressure rating of up to 200 psig and temperature rating of up to 10 to 115 degree C.

  • Guard columns can provide many benefits when used upstream from an analytical, preparative, or semi-preparative column. Guard columns are typically chosen to have the same packing as the primary column. Any compounds or particulate material that would block the frits or highly adsorb to the primary…

  • The Hamilton plunger assembly is suitable for use with CR-700-20 constant rate syringe models.

  • Wide selection of ergonomic pipettes Completely autoclavable Guaranteed accuracy and precision All pipettes have color-coded plunger buttons and labels for easy volume identification. SoftGrip air-displacement pipettes are built from high quality, state-of-the-art materials designed to provide…

  • Actuated Manual   Break Away Torque 15 oz-in (105.9 mNm)   Fluid Path PTFE/CTFE   Housing Material Aluminum   Nominal Port Diameter 0.059 inch (1.5 mm) …

  • The Small Hub Removable Needle (RN) is compatible with RN syringes from 2.5 µL to 100 µL. Needles are available from 34 to 18 gauge. All needles are sold in six-packs and the standard needles are 51 mm long. For all custom needles, the length and point style will need to be specified prior to…

  • The Hamilton barrel/plunger assembly is suitable for use with 25 uL 802RN syringe models. No needle included

Compare Tool

Select up to 3 products