Agilent Technologies, 0.25 mm, Equipment
-
DB-1701
Agilent Technologies(14%-Cyanopropyl-phenyl)-methylpolysiloxane Low/midpolarity Bonded and cross-linked Solvent rinsable Exact replacement for HP-1701 Similar Phases: DB-1701: SPB-1701, CP-Sil 19 CB, Rtx-1701, BP-10, OV-1701, 007-1701, ZB-170 Agilent Technologies products are intended for…
-
Cyclodex-B
Agilent Technologies10.5% Beta-Cyclodextrin in DB-1701 Chiral separations without chiral specific derivatization Broad range of resolving potential Excellent peak shape Similar Phases: LIPODEX C, Rt-β DEXm, β -DEX 110, β -DEX 120 Because Cyclodex-B GC columns are not bonded or cross-linked,…
-
DB-5.625
Agilent TechnologiesEquivalent to a (5%-Phenyl)-methylpolysiloxan Non-polar Specially processed to exhibit excellent inertness for EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols* Surpasses EPA performance criteria for semivolatiles Inert for base, neutral and acidic compounds High…
-
CAM
Agilent TechnologiesBase deactivated polyethylene glycol Specifically designed for amine analysis Excellent peak shape for primary amines Replaces HP-Basicwax Similar Phases: Stabilwax-DB, Carbowax Amine Because the CAM is not bonded or cross-linked, we do not recommend solvent rinsing. …
-
DB-5 And DB-5ms
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-5 (2713R99, T86, T94 and V89) (5%-Phenyl)-methylpolysiloxane Non-polar …
-
HP-Ms
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Identical selectivity to HP-5 Non-polar …
-
HP-1ms
Agilent Technologies100% Dimethylpolysiloxane Identical selectivity to HP-1 Non-polar Low bleed characteristics General purpose column Improved signal-to-noise ratio for better sensitivity and mass spectral integrity Bonded and cross-linked Solvent rinsable Temperature range:…
-
DB-17ht
Agilent Technologies(50%-Phenyl)-methylpolysiloxane Midpolarity Extended upper temperature limit of 365°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Improved resolution for triglycerides Ideal for…
-
DB-XLB
Agilent TechnologiesExceptionally low bleed Low polarity Extended temperature limit of 340°/360°C Exhibits inertness to active compounds Suitable for confirmational analysis Excellent for pesticides, herbicides, PCBs and PAHs Useful for GC/MS MSD testing and certification…
-
HP-5ms
Agilent TechnologiesMeets EN14331 Standards (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass spectral integrity Bonded and cross-linked…
-
Deactivated Fused Silica Tubing
Agilent TechnologiesDeactivated tubing can be used as retention gaps, guard columns, or transfer lines. Our standard deactivation process is a phenyl methyl deactivation — the preferred choice for most applications due to its inertness and robustness. Agilent Technologies products are intended for…
-
DB-624
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Specifically designed for the analysis of volatile priority pollutants No…
-
DB-Petro
Agilent Technologies100% Dimethylpolysiloxane Configured for the analysis of petroleum process products PONA, PIANO High resolution Bonded and cross-linked Solvent rinsable Similar Phases: Petrocol DH, HP-PONA, SPB-1, 007-1, Rtx-1, MXT-1 100 psi regulator required to reach optimum…
-
Se-30 And Se-54
Agilent TechnologiesSE-30: 100% Dimethylpolysiloxane SE-54: (5%-Phenyl)(1%-Vinyl)-methylpolysiloxane Because SE series GC columns are not bonded or cross-linked, we do not recommend solvent rinsing. Agilent Technologies products are intended for sale/shipment within the US only. International customers…
-
DB-225ms
Agilent TechnologiesVirtually equivalent to (50%-Cyanopropylphenyl)-methylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Low bleed Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G7 Similar Phases:…
-
Columns Capillary HP-88 100m, 0.25mm id, 0.2um
Agilent Technologies(88%-cyanopropyl) aryl-polysiloxane 250/320°C upper temperature limits High Polarity Designed for separation of cis/trans fatty acid methyl esters Even better separation than DB-23 of cis-trans isomers Similar Phases: CP-Sil 88, SP-2560, SP-2340, SP-2330, BPX-70, BPX-90…
-
DB-1301
Agilent Technologies(6%-Cyanopropyl-phenyl) methylpolysiloxane Equivalent to USP Phase G43 Low/midpolarity Bonded and cross-linked Exact replacement of HP-1301 Solvent rinsable Similar Phases: Rtx-1301, PE-1301 Agilent Technologies products are intended for sale/shipment within…
-
DX-1 And DX-4
Agilent TechnologiesDX-1: 90% Dimethylpolysiloxane - 10% Polyethylene Glycol DX-4: 15% Dimethylpolysiloxane - 85% Polyethylene Glycol Because DX series GC columns are not bonded and cross-linked, we do not recommend solvent rinsing. Agilent Technologies products are intended for sale/shipment within…
-
DB-200
Agilent Technologies(35% Trifluoropropyl)-methylpolysiloxane 300/320°C temperature limit Midpolarity (more polar than DB-1701 or DB-17) Ideal for difficult to separate positional isomers Unique interactions with compounds containing nitro, halogen and carbonyl groups Low ECD bleed …
-
DB-1301 And DB-1701
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-1301: (6%-Cyanopropyl-phenyl) methylpolysiloxane DB-1301: Equivalent to USP…
-
Carbowax 20m And HP-20m
Agilent TechnologiesPolyethylene glycol, MW 20,000 Equivalent to USP Phase G16 Similar Phases: DB-WAX, HP-INNOWax, DB-WAXetr Because the Carbowax 20M and the HP-20M are not bonded or cross-linked, we do not recommend solvent rinsing. DB-WAX is the recommended bonded alternate for the HP-20M. …
-
DB-Dioxin
Agilent TechnologiesSpecifically engineered for the analysis of polychlorinated dibenzodioxins (PCDDs) and dibenzofurans (PCDFs) Resolves 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in one run Low bleed Bonded and cross-linked Solvent rinsable Similar Phases: SP-2331, 007-23,…
-
HP-1
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Non-polar Excellent general purpose column -…
-
HP-Chiral
Agilent TechnologiesBeta-cyclodextrin in (35%-Phenyl)-methylpolysiloxane Chiral separations without chiral specific derivatization Phenyl-based polymer provides low bleed and does not interfere with nitrogen-specific detectors. Available in two concentrations of beta-cyclodextrin: 10% and 20% 20%…
-
DB-VRX 60m, .25mm, 1.4um, 5"Cage
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Unique selectivity engineered for optimum resolution of volatiles analysis: U.S. EPA…
-
HP-Pona
Agilent Technologies100% Dimethylpolysiloxane Configured for the analysis of petroleum process products Tested to ensure the resolution of m-xylene from p-xylene and of cyclopentane from 2,3-dimethylbutane PONA, PIANO High resolution Bonded and cross-linked Solvent rinsable Similar…