Agilent Technologies, Columns, 0.32 mm
Agilent Technologies
Efficient LC Solutions that deliver the fast, reproducible results you need
-
HP-FFAP
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Nitroterephthalic acid modified polyethylene glycol High polarity Temperature…
-
DB-ALC1 And DB-ALC2
Agilent TechnologiesMeets EN14110 standard Reliable blood alcohol analysis Optimized primary and confirmation column pair for U.S. blood alcohol analysis Faster GC run times Improved resolution of key ethanol/acetone peaks Available in 0.32 and 0.53 mm ID Bonded and cross-linked …
-
DB-17ms
Agilent TechnologiesVirtually equivalent to (50%-Phenyl)-methylpolysiloxane 320°/340°C upper temperature limit Very low bleed midpolarity, suitable for GC/MS Exhibits inertness to active compounds Enhanced mass spectral integrity Bonded and cross-linked Solvent rinsable Best…
-
HP-FFAP
Agilent TechnologiesNitroterephthalic acid modified polyethylene glycol High polarity Temperature range from 40 to 250°C Designed for the analysis of volatile fatty acids and phenols Replaces OV-351 Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 …
-
DB-17
Agilent Technologies(50%-Phenyl)-methylpolysiloxane Midpolarity slightly more polar than HP-50+ Suitable for confirmational analyses Bonded and cross-linked Solvent rinsable Temperature limits are 40° to 260/280°C or 40° to 280/300°C Equivalent to USP Phase G3 HP-50+, Rtx-50,…
-
HP-5ms
Agilent TechnologiesMeets EN14331 Standards (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass spectral integrity Bonded and cross-linked…
-
HP-1ms
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Identical selectivity to HP-1 Non-polar Low…
-
Se-30 And Se-54
Agilent TechnologiesSE-30: 100% Dimethylpolysiloxane SE-54: (5%-Phenyl)(1%-Vinyl)-methylpolysiloxane Because SE series GC columns are not bonded or cross-linked, we do not recommend solvent rinsing. Agilent Technologies products are intended for sale/shipment within the US only. International customers…
-
DB-Wax
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity …
-
Undeactivated Fused Silica Tubing
Agilent TechnologiesUndeactivated tubing or bare fused silica is commonly used for capillary electrophoresis. It can also be used for transfer lines and other applications where inertness is not critical. Agilent Technologies products are intended for sale/shipment within the US only. International customers…
-
CAM
Agilent TechnologiesBase deactivated polyethylene glycol Specifically designed for amine analysis Excellent peak shape for primary amines Replaces HP-Basicwax Similar Phases: Stabilwax-DB, Carbowax Amine Because the CAM is not bonded or cross-linked, we do not recommend solvent rinsing. …
-
DB-Tph 30m, 0.32mm, 0.25um
Agilent TechnologiesSpecifically designed for the analysis of total petroleum hydrocarbons (TPHs), soil analysis, and LUFT Three analyses in one injection: gas range organics, diesel range organics and motor oil Fast run time Bonded and cross-linked Solvent rinsable Agilent Technologies…
-
DB-5
Agilent Technologies(5%-Phenyl)-methylpolysiloxane Non-polar General purpose column Wide range of applications Low bleed High temperature limit: -60° to 325/350°C* Bonded and cross-linked Solvent rinsable Wide range of column dimensions available Equivalent to USP…
-
DB-Wax
Agilent TechnologiesPolyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes Column-to-column repeatability Bonded and cross-linked Solvent rinsable …
-
Ultra 1 & Ultra 2
Agilent TechnologiesUltra 1: 100% Dimethylpolysiloxane Ultra 2: (5%-Phenyl)-methylpolysiloxane Non-polar Bonded and cross-linked Solvent rinsable HP-1 and HP-5 with tighter specifications for retention index and capacity factors Temperature range: -60° to 325°/350°C …
-
Deactivated Fused Silica Tubing
Agilent TechnologiesDeactivated tubing can be used as retention gaps, guard columns, or transfer lines. Our standard deactivation process is a phenyl methyl deactivation — the preferred choice for most applications due to its inertness and robustness. Agilent Technologies products are intended for…
-
HP-35
Agilent Technologies(35%-Phenyl)-methylpolysiloxane Midpolarity - slightly less polar than DB-35 Inert to active solutes Ideal for confirmational analyses Bonded and cross-linked Solvent rinsable Equivalent to USP Phase G42 Similar Phases: Rtx-35, SPB-35, AT-35, Sup-Herb, DB-35,…
-
DB-5ht
Agilent TechnologiesMeets ASTM 6584 and EN14105 Standards 100% Dimethylpolysiloxane Non-polar Specially processed for extended temperature limit of 400°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Bonded and…
-
DB-Waxetr
Agilent TechnologiesPolyethylene glycol (PEG) Extended Temperature Range (etr) High polarity Excellent column-to-column repeatability Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G16 Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52 CB, SUPEROX II, CB-WAX,…
-
DB-17ht
Agilent Technologies(50%-Phenyl)-methylpolysiloxane Midpolarity Extended upper temperature limit of 365°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Improved resolution for triglycerides Ideal for…
-
Cyclodex-B
Agilent Technologies10.5% Beta-Cyclodextrin in DB-1701 Chiral separations without chiral specific derivatization Broad range of resolving potential Excellent peak shape Similar Phases: LIPODEX C, Rt-β DEXm, β -DEX 110, β -DEX 120 Because Cyclodex-B GC columns are not bonded or cross-linked,…
-
DB-XLB
Agilent TechnologiesExceptionally low bleed Low polarity Extended temperature limit of 340°/360°C Exhibits inertness to active compounds Suitable for confirmational analysis Excellent for pesticides, herbicides, PCBs and PAHs Useful for GC/MS MSD testing and certification…
-
GS-Gaspro
Agilent TechnologiesBonded PLOT column technology Suitable for light hydrocarbons and sulfur gas Retention stability not affected by water Separates CO and CO2 on a single column Ideal PLOT column for CG/MS - no particles Temperature limits: -80° to 260°/300°C …
-
DB-35
Agilent Technologies(35%-Phenyl)-methylpolysiloxane Midpolarity - slightly more polar than HP-35 Low bleed Inert to active solutes Ideal for confirmational analyses Bonded and cross-linked Solvent rinsable Equivalent to USP Phase G42 Similar Phases: Rtx-35, SPB-35, AT-35,…
-
GS-Carbonplot
Agilent TechnologiesAgilent J&W GS-CarbonPLOT uses a high stability, carbon-layer stationary phase to deliver unique selectivity for inorganic and organic gases. The column features an extended temperature limit to 360 °C. The retention stability of GS-CarbonPLOT is not affected by water, and the column is…
-
DB-5ms
Agilent TechnologiesPhenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass…
-
HP-1
Agilent Technologies100% Dimethylpolysiloxane Industry standard general purpose column Non-polar Wide range of applications Superior performance of low molecular weight alcohols High temperature limit Bonded and cross-linked Solvent rinsable Wide range of column dimensions …
-
DB-1
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Non-polar Excellent general purpose column …
-
DB-1ms
Agilent Technologies100% Dimethylpolysiloxane Identical selectivity to DB-1 Non-polar Very low bleed characteristics, ideal for GC/MS Improved acid performance compared to standard 100% Dimethylpolysiloxane columns Improved signal-to-noise ratio for better sensitivity and mass spectral integrity …
-
DB-1ht
Agilent Technologies100% Dimethylpolysiloxane Non-polar Specially processed for extended temperature limit of 400°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Bonded and cross-linked Solvent rinsable …
-
DB-210
Agilent Technologies(50%-Trifluoropropyl)-methylpolysiloxane High polarity Excellent for U.S. EPA Methods 8140 and 609 Bonded and cross-linked Solvent rinsable Exact replacement of HP-210 Close equivalent to USP Phase G6 Similar Phases: SP-2401 Agilent Technologies products…
-
DB-624
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Specifically designed for the analysis of volatile priority pollutants No…