Ace Glass, Equipment, Columns
-
Safety Shield, Plastic, Michel-Miller
Ace GlassAcrylic safety shield and polyethylene cap for use with Michel-Miller Columns to insure safe operation at pressures to 300 psi. Top thread of column is hung in polyethylene cap; cap is then held by the plastic shield. Clamp the shield, not the column.
-
Plain, open top, chromatographic column, with porosity B (70 - 100 m) fritted disc sealed in.
-
Chromatographic column with 2mm bore, 1:5 taper solid PTFE stopcock plug and porosity B (70 - 100 m) fritted disc sealed in.
-
Chromatographic Column, With Filter Disc
Ace GlassChromatographic column with 24/40 joint at top, 2 mm bore 1:5 taper solid PTFE stopcock plug at bottom and porosity B (70 - 100 m) fritted disc sealed near bottom of tube. These columns also appear in expanded listing under 5871.
-
Chromatographic column with integral reservoir and #15 Ace-Thred at top, and 2mm bore 1:5 taper PTFE plug at bottom. Column supplied with 7506-06 Nylon bushing and FETFE O-Ring. Complete item consists of column with bushing and O-Ring, and 5853-07 Tubing Connector for connecting 12.5 to 14mm O.D.…
-
Column has standard taper 24/40 joint at top and 2 mm bore stopcock at the bottom with Por. B (70-100m) fritted disc sealed into the bottom of tube.
-
Adjusta-chrom, Column, Michel-Miller
Ace GlassA combination of the high performance, low pressure Michel-Miller Chromatography Line and Adjusta-Chrom Recycling Column. Top has adjustable fitting that allows for a bed height anywhere within 1 - 6" below thread. Plunger tip is all PTFE with a porosity C (25-50m) glass disc. Complete column…
-
For use as column end fitting that allows connection of appropriate size Ace-Thred to tubing connectors with NPT threads. Available in various Ace-Thred and NPT sizes. Most come complete with both a 100 micron and a 350 micron polyethylene filter.
-
Distilling Column, Vigreux
Ace GlassWith male drip tip on joint of Claisen side arm and 10/30 joint for 25 mm immersion thermometer. Other joints are 14/20.
-
Simple absorption chromatography column for rapid preparative separations with moderate resolution. Allows separations of samples from 0.01 to 10.0g in 10-15 minutes. Column and reservoir, only, are Epoxy Coated. Reservoir connects between column and flow control adap-ter. Joints on column,…
-
Concentric Tube Column
Ace GlassA high efficiency, low holdup, low pressure drop fractionating column, vacuum jacketed with observation stripe. Suitable for samples as small as 2mL. Center tube is removable for cleaning. Double expansion spiral eliminates choking. Joints are 14/20. A
-
High performance, non-packed, low pressure liquid chromatography columns, epoxy-coated. Simple to assemble, PTFE (no O-rings), safe operation to 150psi with safety shield. Usable with various packing materials chemically inert, zero dead volume, leak free. For analytical or preparative…
-
Distilling Column, Vigreux
Ace GlassLength in millimeters refers to the effective length of the column as measured from the lowest to the highest indent of the column. Available in a microscale version, top center joint is 14/10 externally threaded for making an O-Ring-Cap-Seal type conn
-
Instatherm® Oil Bath
Ace GlassOil baths heated by Instatherm®, an integral noble metal alloy fused permanently to the glass & covered with a tough silicone rubber treated glass cloth insulation which serves as a thermal barrier as well as protection against physical shock. Rapid heat response - low thermal lag. For…
-
Column, Chromatography
Ace GlassWith 24/40 standard taper joint at top and a 2 mm bore stopcock at the bottom.
-
Adjusta-chrom, Recycling Column
Ace GlassAdjustable bed chromatographic column used for recycling, ascending or descending applications allowing for quick and easy adjustment of the PTFE plunger. The Por. C (25-50m) glass disc gives rapid flow with a minimum of mixing. Pressure tight to 3.515 Kg/cm2 (50 psi) at room temperature or…
-
Column, Chromatography
Ace GlassLarge chromatography columns with o-ring grooved flat flanged tops and Ace-Thred bottoms. Column extenders and 5860 heads should be mated to columns with our 6517 series clamps. All columns and extenders are supplied with either a 7855-254 (4") or 7855-260 (6") silicone o-ring. For capfe o-rings,…
-
Filter Column, Michel-Miller
Ace GlassFor use with Michel-Miller Liquid Chromatography System as filter to assure only clean solvent enters column. Threads are #7 Ace-Thred for use with 5801-07 End Fitting. Usually positioned, in line, between pump and column using 1/4"-28 tubing connectors such as 5854, 5855 or 12724. Glass only is…
-
Simple absorption chromatography column for rapid preparative separations with moderate resolution. Allows separations of samples from 0.01 to 10.0g3 in 10-15 minutes. Column and reservoir, only, are Epoxy Coated. Reservoir connects between column and flow control adap-ter. Joints on column,…
-
Chromatographic column with integral reservoir for connecting 5872 Flow Control Adapter. With 2mm bore, 1:5 taper solid PTFE stopcock plug at bottom. Available with or without porosity B (70 - 100 m) fritted disc sealed in. Order column, flow control adapter and clamp separately.
-
Distilling Column, Jacketed
Ace GlassJacket length 250 mm, with indents for supporting glass beads or other packing.
-
Adsorption Column
Ace GlassUsed in ASTM D1319-65T, a "test for hydrocarbon types in liquid petroleum products." This unit is fabricated from ACE Trubore tubing. Tip is attached to column by means of a 12/2 spherical joint. Upper joint spherical 28/12.
-
Distilling Column
Ace GlassVacuum jacketed and silvered with observation stripe. Also available unsilvered. With an enlarged bulb knockdown section that removes high boiling ends without choking. Length of packing section is 100 or 200mm, I.D. approximately 10mm. With indents to
-
Coupling, Michel-Miller
Ace GlassPrecision made PTFE coupling with 316 stainless steel liner for connecting Michel-Miller, or 5820 columns when packing. Designed to make a leak-tight seal without the use of O-Rings. Simply tighten until white ring appears indicating a seal has been made, secure locknut; no need to tighten further.…
-
Jacketed, adjustable bed chromatographic column used for recycling, ascending descending applications. Completely jacketed for better temperature uniformity with single bushing at each end allowing for quick and easy adjustment of the PTFE plunger. the 25-50 micron porous glass disc gives rapid…
-
Chromatographic Column, 1:5 PTFE Plug
Ace GlassChromatographic column with 2mm bore 1:5 taper solid PTFE stopcock plug at bottom.
-
Designed for metal recovery using Ion-Exchange resins such as Amborane. Borosilicate glass column has #25 Ace-Thred at both ends. Polypropylene end fittings form a leak-tight seal with FETFE O-Rings. Fittings have 1/4" npt female thread for connecting 3/8" O.D. flexible vinyl tubing from…
-
Chromatographic Column, Plain
Ace GlassPlain, open top, chromatographic column, universally suitable for many separations.
-
Adapter, Injection Port, Michel-Miller
Ace GlassA simple, all PTFE septum injector. Allows direct, on-column injection to the center of the filter disc at top of column without stopping the solvent flow through the 1/4"-28 female side thread (with or without helicoil). Locknut design provides leaktight seal without o-rings. You can order the…
-
Column, Chromatography
Ace GlassRugged columns with internally threaded ends to which a wide choice of upper and lower end pieces can be fitted using 5837, 5838, 5841, 5842, and 5843 fittings. Available in a variety of lengths and diameters. Some sizes available with epoxy coating for added protection against scratches.
-
Chromatographic Column, 1:5 PTFE Plug
Ace GlassChromatographic column with integral reservoir at top, and 2 mm bore 1:5 taper PTFE stopcock plug at bottom. Opening at top is either 24/40 outer joint or opening for #3 stopper. Available with or without porosity B (70-100micron), fritted disc sealed in.
-
Float, Polyethylene
Ace GlassUsed on top of column packing to prevent turbulence caused by drop-wise addition. Six per pkg.