Restek, Equipment
-
A traditional end-capped C18 ideal for general-purpose use in reversed-phase chromatography Wide pH range (2–8) provides excellent data quality for many applications, matrices, and compounds Offers high hydrophobic retention Similar Phase(s): Discovery C18, Symmetry C18, Hypersil…
-
High-quality, silica-based hydrophobic adsorbents. Used for common sample matrices such as food, soil, and water. Ideal when less retention than a C18 is needed. Stable over the pH range (2 – 8).
-
-
midpolarity Crossbond phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…
-
Allure AK Columns
RestekThis highly retentive, highly selective phase—unique to Restek—was developed specifically for the analysis of aldehydes and ketones as DNPH derivatives. Allure AK is a reversed-phase HPLC material that has the unique ability to separate all 13 carbonyl compounds specified in California…
-
Roc HPLC columns are built to be the cornerstone for your LC lab. These solid, reliable columns are pressure rated for any 400 bar HPLC system and deliver the peak shape, reproducibility, ruggedness, and performance you demand for all of your conventional HPLC applications. An exceptional value,…
-
Ultra Quat Columns
RestekA retentive, high-purity, base-deactivated, reversed-phase packing. Ideal for the analysis of paraquat and diquat or other quaternary amines. Particle Size: 3 µm or 5 µm, spherical Pore Size: 100 Å pH Range: 2.5 to 8 Temperature Limit: 80°C
-
low-polarity phase; Crossbond 5% diphenyl/95% dimethyl polysiloxane Active basic compounds that otherwise require derivatization, or an alternative analytical technique, can be analyzed on an Rtx-5 Amine column. The tubing surface is chemically altered to reduce tailing of basic compounds,…
-
Ultra HPLC Columns The Ultra line represents Restek’s broadest selection of stationary phases on a single silica support. Made of high-purity, type-B silica that minimizes activity and creates high-density bonding, these columns are designed for selective and reliable HPLC applications. …
-
nonpolar phase; Crossbond dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of…
-
Ultra C18 Columns (USP L1)
RestekUltra HPLC Columns The Ultra line represents Restek’s broadest selection of stationary phases on a single silica support. Made of high-purity, type-B silica that minimizes activity and creates high-density bonding, these columns are designed for selective and reliable HPLC applications. …
-
Restek Rt-Alumina BOND columns are highly selective for C1–C5 hydrocarbons and separate all saturated and unsaturated hydrocarbon isomers above ambient temperatures. The reactivity of the aluminum oxide stationary phase is minimized, by deactivation with inorganic salts like KCl or…
-
Extend column lifetime. Excellent inertness—obtain lower detection limits for active compounds. Sharper chromatographic peaks by utilizing retention gap technology. Maximum temperature: 360°C
-
Viva HPLC Columns: 3 or 5 µm particles; 300 Å pore size Excellent for separating peptides or proteins Rugged, spherical particles with 300 Å pore size High proportion of pore/surface area available to large molecules Viva columns are based on a wide pore material…
-
midpolarity phase; Crossbond 35% diphenyl/65% dimethyl polysiloxane Active basic compounds that otherwise require derivatization, or an alternative analytical technique, can be analyzed on an Rtx-35 Amine column. The tubing surface is chemically altered to reduce tailing of basic compounds,…
-
high-polarity phase; Crossbond diphenyl dimethyl polysiloxane The Rtx-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number. Because of the chemistry required to achieve 370°C thermal stability, an Rtx-65TG column should not be used for the analyses of…
-
Topaz GC inlet liners feature revolutionary technology and inertness to deliver you the next level of True Blue Performance: Deactivation —unbelievably low breakdown for accurate and precise low-level GC analyses Reproducibility —unbeatable manufacturing controls and QC…
-
polar phase; Crossbond acid-deactivated Carbowax polyethylene glycol—for acidic compounds Stabilwax-DA bonded polyethylene glycol has an acidic functionality incorporated into the polymer structure. This permits analysis of acidic compounds without derivatization, significantly reduces…
-
midpolarity Crossbond phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…
-
Stabilwax-MS columns ensure reproducible retention times from run to run, even with temperature cycling. When methods require trace analysis, this highly polar, low-bleed stationary phase produces excellent signal-to-noise levels! Ideal for food and flavor analysis (e.g., essential oils), fragrance…
-
Extend analytical column lifetime by preventing degradation from harsh “steam-cleaning” water injections. Tested with a comprehensive test mix, to ensure high inertness Maximum temperature: 325°C When transfer lines from purge-and-trap systems, air monitoring equipment,…
-
Column bleed, measured by ECD, is extremely low at temperatures up to 330°C, which is critical for baking-out the column to remove high-boiling compounds commonly found in pesticide/PCB extracts. An analysis time of less than 10 minutes improves throughput compared to other stationary phases. …
-
Includes inlet adaptor, retaining nut, back washer, and hot swap column nut. Makes column installation quicker and easier. Provides a leak-free seal for all applications. Siltek-treated version available for increased inertness. Meets or exceeds original manufacturer’s performance.
-
nonpolar phase; Crossbond 100% dimethyl polysiloxane—for simulated distillation MXT-2887 columns' stationary phase, column dimensions, and film thicknesses have been optimized to exceed the resolution and skewing factor requirements specified in ASTM Method D2887. Each column is…
-
2,3-di-O-ethyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to…
-
Proprietary cyclodextrin material added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to columns that have pure…
-
Topaz GC inlet liners feature revolutionary technology and inertness to deliver you the next level of True Blue Performance: Deactivation —unbelievably low breakdown for accurate and precise low-level GC analyses Reproducibility —unbeatable manufacturing controls and QC…
-
proprietary Crossbond phase Rtx-VMS columns offer lower bleed, better selectivity, and overall faster analysis for separating volatile organic compounds, such as those listed in U.S. EPA Method 8260B. The Rtx-VMS stationary phase is a highly stable polymer that provides outstanding analysis of…
-
Viva Silica Columns (USP L3)
RestekViva HPLC Columns: 3 or 5 µm particles; 300 Å pore size Excellent for separating peptides or proteins Rugged, spherical particles with 300 Å pore size High proportion of pore/surface area available to large molecules Viva columns are based on a wide pore material…
-
midpolarity Crossbond phase Rtx-1701 is one of the more popular stationary phases used in capillary GC. The mix of cyano and phenyl functional groups increases the polarity and offers a different elution order relative to less polar Rtx-1 or Rtx-5 columns. An Rtx-1701 column is ideal for…
-
proprietary Crossbond diphenyl/dimethyl polysiloxane phase An Rtx-502.2 column will enable you to quantify all compounds listed in U.S. EPA methods 502.2 or 524.2, whether you use a mass spectrometer or a PID in tandem with an ELCD. The diphenyl/dimethyl polysiloxane based Rtx-502.2 stationary…
-
The Rtx-Volatile Amine column was designed specifically for analyzing volatile amines in difficult matrices, such as water. The unique base deactivation creates an exceptionally inert surface for these sensitive compounds, resulting in highly symmetrical peaks, which allow low detection limits. The…