0.25 mm
-
DB-Petro 100m, .25mm, 0.5um, 5"Cage
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Configured for the analysis of petroleum process…
-
DB-210
Agilent Technologies(50%-Trifluoropropyl)-methylpolysiloxane High polarity Excellent for U.S. EPA Methods 8140 and 609 Bonded and cross-linked Solvent rinsable Exact replacement of HP-210 Close equivalent to USP Phase G6 Similar Phases: SP-2401 Agilent Technologies products…
-
Se-30 And Se-54
Agilent TechnologiesSE-30: 100% Dimethylpolysiloxane SE-54: (5%-Phenyl)(1%-Vinyl)-methylpolysiloxane Because SE series GC columns are not bonded or cross-linked, we do not recommend solvent rinsing. Agilent Technologies products are intended for sale/shipment within the US only. International customers…
-
Undeactivated Fused Silica Tubing
Agilent TechnologiesUndeactivated tubing or bare fused silica is commonly used for capillary electrophoresis. It can also be used for transfer lines and other applications where inertness is not critical. Agilent Technologies products are intended for sale/shipment within the US only. International customers…
-
HP-FFAP
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Nitroterephthalic acid modified polyethylene glycol High polarity Temperature…
-
HP-5ms
Agilent TechnologiesMeets EN14331 Standards (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass spectral integrity Bonded and cross-linked…
-
Cyclosil-B
Agilent Technologies30% heptakis (2,3-di-O-methyl-6-O-t-butyl dimethylsilyl)-β -cyclodextrin in DB-1701 Chiral separations without chiral specific derivatization New stationary phase for improved resolution of many chiral separations Suitable for many chiral γ -lactones and terpenes Similar…
-
DB-225ms
Agilent TechnologiesVirtually equivalent to (50%-Cyanopropylphenyl)-methylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Low bleed Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G7 Similar Phases:…
-
DB-624
Agilent TechnologiesSpecifically designed for the analysis of volatile priority pollutants No cryogenics needed for U.S. EPA Method 502.2 Excellent for U.S. EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240 and 8260 Exhibits inertness to active compounds Bonded and cross-linked Solvent…
-
DB-5ht
Agilent TechnologiesMeets ASTM 6584 and EN14105 Standards 100% Dimethylpolysiloxane Non-polar Specially processed for extended temperature limit of 400°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Bonded and…
-
HP-5
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Non-polar Excellent general purpose column …
-
DB-XLB
Agilent TechnologiesExceptionally low bleed Low polarity Extended temperature limit of 340°/360°C Exhibits inertness to active compounds Suitable for confirmational analysis Excellent for pesticides, herbicides, PCBs and PAHs Useful for GC/MS MSD testing and certification…
-
Deactivated Fused Silica Tubing
Agilent TechnologiesDeactivated tubing can be used as retention gaps, guard columns, or transfer lines. Our standard deactivation process is a phenyl methyl deactivation — the preferred choice for most applications due to its inertness and robustness. Agilent Technologies products are intended for…
-
DB-17ht
Agilent Technologies(50%-Phenyl)-methylpolysiloxane Midpolarity Extended upper temperature limit of 365°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Improved resolution for triglycerides Ideal for…
-
GC Capillary Column
Agilent TechnologiesAgilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…
-
DB-1ms
Agilent Technologies100% Dimethylpolysiloxane Identical selectivity to DB-1 Non-polar Very low bleed characteristics, ideal for GC/MS Improved acid performance compared to standard 100% Dimethylpolysiloxane columns Improved signal-to-noise ratio for better sensitivity and mass spectral integrity …
-
GC Capillary Column
Agilent TechnologiesAgilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…
-
GC Capillary Column
Agilent TechnologiesAgilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…
-
DB-1701
Agilent Technologies(14%-Cyanopropyl-phenyl)-methylpolysiloxane Low/midpolarity Bonded and cross-linked Solvent rinsable Exact replacement for HP-1701 Similar Phases: DB-1701: SPB-1701, CP-Sil 19 CB, Rtx-1701, BP-10, OV-1701, 007-1701, ZB-170 Agilent Technologies products are intended for…
-
GC Capillary Column
Agilent TechnologiesAgilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…
-
HP-FFAP
Agilent TechnologiesNitroterephthalic acid modified polyethylene glycol High polarity Temperature range from 40 to 250°C Designed for the analysis of volatile fatty acids and phenols Replaces OV-351 Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 …
-
DB-17ms
Agilent TechnologiesVirtually equivalent to (50%-Phenyl)-methylpolysiloxane 320°/340°C upper temperature limit Very low bleed midpolarity, suitable for GC/MS Exhibits inertness to active compounds Enhanced mass spectral integrity Bonded and cross-linked Solvent rinsable Best…
-
HP-1
Agilent Technologies100% Dimethylpolysiloxane Industry standard general purpose column Non-polar Wide range of applications Superior performance of low molecular weight alcohols High temperature limit Bonded and cross-linked Solvent rinsable Wide range of column dimensions …
-
DB-Waxetr
Agilent TechnologiesPolyethylene glycol (PEG) Extended Temperature Range (etr) High polarity Excellent column-to-column repeatability Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G16 Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52 CB, SUPEROX II, CB-WAX,…
-
Duraguard Columns
Agilent TechnologiesColumns with “built in” guard columns, no press-fit connectors Minimize front-end contamination and increase column lifetime Aid in focusing sample onto the front of the column for better peak shape Minimize MSD contamination originating from the column (when used in…
-
CAM
Agilent TechnologiesBase deactivated polyethylene glycol Specifically designed for amine analysis Excellent peak shape for primary amines Replaces HP-Basicwax Similar Phases: Stabilwax-DB, Carbowax Amine Because the CAM is not bonded or cross-linked, we do not recommend solvent rinsing. …
-
DB-Wax
Agilent TechnologiesPolyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes Column-to-column repeatability Bonded and cross-linked Solvent rinsable …
-
DB-5 And DB-5ms
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-5 (2713R99, T86, T94 and V89) (5%-Phenyl)-methylpolysiloxane Non-polar …
-
DB-FFAP
Agilent TechnologiesNitroterephthalic acid modified polyethylene glycol High polarity Designed for the analysis of volatile fatty acids and phenols Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 Temperature limits: 40° to 250°C NOTE: Agilent does…
-
DB-1ht
Agilent Technologies100% Dimethylpolysiloxane Non-polar Specially processed for extended temperature limit of 400°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Bonded and cross-linked Solvent rinsable …
-
HP-35
Agilent Technologies(35%-Phenyl)-methylpolysiloxane Midpolarity - slightly less polar than DB-35 Inert to active solutes Ideal for confirmational analyses Bonded and cross-linked Solvent rinsable Equivalent to USP Phase G42 Similar Phases: Rtx-35, SPB-35, AT-35, Sup-Herb, DB-35,…
-
DB-Wax
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity …