Thermo Scientific LC Chromatography Columns

Compare Tool

Select up to 3 products

HomeAll Products

Thermo Scientific Columns LC Chromatography Columns

1 - 32 of 61
Sort
View
Show
  • Thermo Scientific

    Polar endcapped C18 phase Alternative selectively compared to conventional C18 phases Compatible with 100% aqueous mobile phases Thermo Scientific Aquasil C18 HPLC Columns provide greater retention than C18 for polar molecules.

  • Separate cationic molecules with powerful adjustable selectivity control using Thermo Scientific™ Acclaim™ Mixed-Mode WCX-1 LC columns. The silica-based stationary phase features a hydrophobic alkyl chain with a carboxyl terminus that provides both hydrophobic reversed-phase and weak…

  • Thermo Scientific

    Ligand on 100 Angstrom silica Thermo Scientific Betasil C18 Columns feature high surface area with high bonded phase coverage.

  • Thermo Scientific

    For the separation of certain aromatic compounds and moderately polar compounds Retention characteristics similar to Hypersil MOS Alternative selectivity to C8 Thermo Scientific Hypersil Phenyl Columns are reversed phase materials…

  • Thermo Scientific

    Extra retention and selectivity for halogenenated compounds Excellent for taxane analysis Thermo Scientific Fluophase PFP HPLC Columns feature perfluorinated phases for unique selectivity.

  • Thermo Scientific

    Highly characterized, tested and validated C18 columns Thermo Scientific HyPURITY C18 Columns are high quality, highly pure silica columns.

  • Thermo Scientific

    Rapidly analyze polyaromatic hydrocarbons (PAHs) with Thermo Scientific™ Hypersil™ green PAH LC columns. Featuring specially tailored alkyl-bonded silica with high carbon loading, these short, fast columns can analyze 16 PAHs in four minutes. Optimized for EPA Method 610: Polynuclear Aromatic…

  • High quality, base deactivated columns Unique selectivity for aromatic and slightly polar compounds Manufactured under ISO 9001:2000 conditions Thermo Scientific Hypersil BDS 5µm Phenyl Columns offer exceptional stability and…

  • Offer 100% porous graphitic carbon for extended separation capabilities with Thermo Scientific™ Hypercarb™ Porous Graphitic Carbon LC Columns. Enhanced retention of polar compounds and separtion of structurally related analytes with stability at pH extremes and high temperature. …

  • Thermo Scientific

    For a high-quality, base-deactivated, fully endcapped phase with similar selectivity to C18 but slightly less retention, use Thermo Scientific™ Hypersil™ BDS C8 HPLC Columns. These economical columns feature reduced silanol activity and provide exceptional reliability for QA/QC labs.…

  • Thermo Scientific

    Choose Thermo Scientific™ Hypersil™ ODS C18 HPLC Columns for a general purpose C18 phase to use in a broad range of applications. Hypersil stationary phases are recognized as an industry standard in HPLC. Proven as an effective analytical tool, the classical Hypersil phases are well established and…

  • Thermo Scientific

    More rapid mobile phase equilibration compared with silica in normal phase Not deactivated by traces of water in normal phase One of the least retentive of reversed phase materials and, therefore, useful to separate polar compounds …

  • Thermo Scientific

    A short alkyl chain reversed phase material Selectivity for polar and multifunctional compounds Can be used in ion-pair separations Thermo Scientific Hypersil SAS C1 Columns have a short alkyl chain solid phase, which makes…

  • Thermo Scientific

    Columns designed to produce reliable, reproducible results for HPLC and UHPLC applications. Products operate in a variety of phases and are available with a range of stationary phases and column dimensions. Includes analytical, guard, trap, and preparative columns. Solve your chromatography…

  • Thermo Scientific

    Improve the separation efficiency in your reversed-phase applications with Thermo Scientific™ Acclaim™ 120 C18 columns. These columns feature an ultrapure silica substrate with extremely low metal content to minimize tailing effects and deliver symmetrical peak shapes. The unique…

  • Thermo Scientific

    In reversed phase mode, Hypersil APS-2 columns are excellent for carbohydrate analysis: extra sensitivity for sugars Alternative selectivity to silica when used in normal phase Thermo Scientific Hypersil APS-2 Columns have a versatile amino propyl…

  • Thermo Scientific

    Based on type A silica Excellent reproducibility Selectivity over wide range of applications Manufactured under ISO 9001:2000 quality guidelines Thermo Scientific Hypersil ODS-2 (C18) HPLC Columns offer a well…

  • Thermo Scientific

    Suited to solve problem separations Exceptional retention of very polar analytes True orthoganality to C18 Separated structurally related substances Excellent for high temperature applications Thermo Scientific Hypercarb Columns offer 100% porous graphitic carbon for…

  • Thermo Scientific

    Significant reduction in peak tailing while retaining C18 selectivity Excellent resolution, efficiency and sensitvity Confidence in the accuracy and quality of analytical data 1.9µm particle size columns can be used to improve speed and efficiency Thermo…

  • Thermo Scientific™ Hypersil GOLD C8 HPLC Columns are recommended for analytes with medium hydrophobicity or when a less hydrophobic phase is required to obtain optimum retention. Based on high purity silica, Hypersil GOLD is a state of the art family of columns designed to meet the challenges of…

  • Thermo Scientific

    The fluorine atoms around the phenyl ring enhance pi-pi interactions with aromatic molecules Alternative selectivity to C18 Extra retention for halogenated species Selectvity for non-halogenated polar compounds Excellent peak shape and…

  • Thermo Scientific

    Improve the consistency and reliability of your liquid chromatography (LC) separations using Thermo Scientific™ Syncronis™ C8 LC columns. High-purity, high surface area silica and dense stationary phase coverage minimize secondary interactions and deliver reproducible, high-efficiency…

  • Thermo Scientific

    The Thermo Scientific Hypersil™ ODS HPLC column is mainly used to separate different kinds of analytes by using HPLC (high pressure liquid chromatography) technique. It is mainly used in research facilities and chemical laboratories. It can be used for reversed phase, cation exchange, anion…

  • Thermo Scientific

    High efficiency and proven reproducibility Exceptionally reliable Separation of a wide range of compounds including nonpolar, moderately polar and lipophilic compounds like triglycerides Thermo Scientific Hypersil ODS (C18) Columns…

  • Ensure consistent, predictable liquid chromatography (LC) separations of polar analytes using Thermo Scientific™ Syncronis™ aQ Columns. High surface area silica and dense stationary phase coverage minimize secondary interactions and deliver reproducible high-resolution separations. The…

  • Thermo Scientific

    Reliable, less retentive phase Long column lifetimes, even under basic conditions Manufactured under ISO 9001-2000 quality guidelines Affordable Thermo Scientific Hypersil MOS (C8) Columns have a monolayer coverage of C8 alkyl chain chemically bonded onto the silica surface for a…

  • For high-resolution, high efficiency analysis of monoclonal antibodies (mAbs) and associated variants, use Thermo Scientific™ MAbPac™ SCX-10 RS Monoclonal Antibody Analysis Columns, 5µm. The unique nonporous pellicular resin provides the resolving power to separate mAb variants that differ by as…

  • Alternate selectivity with lower hydrophobicity. Use Thermo Scientific™ Hypersil Gold™ Cyano LC Columns for normal and reversed phase separations. Excellent peak shape Outstanding sensitivity Less retention for faster analysis

  • Thermo Scientific™ Hypersil GOLD aQ polar endcapped C18 columns provide a controlled interaction mechanism by which polar analytes can be retained and resolved. Based on high purity silica, Hypersil GOLD is a state of the art family of columns designed to meet the challenges of modern…

  • Thermo Scientific

    In reversed phase, they offer different selectivity compared to C18 or C8 phases In normal phase, they are less retentive than silica columns Reliable cyano columns with long lifetimes Thermo Scientific Hypersil BDS 5µm…

  • Thermo Scientific

    In reversed phase mode, Hypersil APS-2 columns are excellent for carbohydrate analysis: extra sensitivity for sugars Alternative selectivity to silica when used in normal phase Thermo Scientific Hypersil APS-2 Columns have a versatile amino propyl phase…

  • Thermo Scientific

    Significant reduction in peak tailing while retaining C18 selectivity Excellent resolution, efficiency and sensitvity Confidence in the accuracy and quality of analytical data Thermo Scientific Hypersil GOLD HPLC Columns are endcapped, ultrapure, silica-based columns with…

Compare Tool

Select up to 3 products