Water Quality, MilliporeSigma, Supplies, Water Quality Test Kits
-
-
-
-
-
UN Number: UN2796
-
Method: colorimetric with test strips and reagent 3 - 10 - 30 - 100 mg/l CrO4 MQuant™ UN Number: UN3316 Storage: Store at +15°C to +25°C. Storage class: 8B Non-combustible, corrosive hazardous materials Hazard: Corrosive The chromate test…
-
All necessary reagents for the analysis are contained in the cells Considerate packaging design protects the cells from fluctuation even in unfavorable environment Elimination of possible mistakes through barcode-system
-
-
Method: colorimetric with test strips and reagent 10 - 25 - 50 - 100 - 200 mg/l Sn MQuant™ UN Number: UN3316 Storage class: 8B Non-combustible, corrosive hazardous materials Storage: Store at +15°C to +25°C. Hazard: Toxic The tin test can be used to…
-
-
-
-
Spectroquant® Iron Test Method: photometric
MilliporeSigmaPrecautionary Statement(s): P280: Wear protective gloves/ protective clothing/ eye protection/ face protection. P301 + P330 + P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. P302 + P352: IF ON SKIN: Wash with plenty of soap and water. P304 + P340: IF INHALED: Remove victim to…
-
Spectroquant® Chloride Test Method: photometric
MilliporeSigmaPrecautionary Statement(s): P273: Avoid release to the environment. P280: Wear protective gloves/ protective clothing. P302 + P352: IF ON SKIN: Wash with plenty of soap and water. P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if…
-
Spectroquant® Fluoride Test Method: photometric
MilliporeSigmaPrecautionary Statement(s): P210: Keep away from heat/sparks/open flames/hot surfaces. - No smoking. P240: Ground/bond container and receiving equipment. P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do.…
-
-
-
Reflectoquant® Ammonium Test
MilliporeSigmaThe test measures both ammonium ions and dissolved ammonia in e.g. groundwater and surface water, seawater, drinking water and aquarium water.
-
Method: colorimetric with test strips 0.5 - 1 - 2 - 3 mg/g KOH MQuant™ Storage class: 10 - 13 Other liquids and solids Storage: Store at +15°C to +25°C. Deep-frying causes oils and fats to decompose over time. One of the major by-products of decomposition is free…
-
Method: colorimetric with test strips and reagent 20 - 40 - 100 - 200 - 500 mg/l Pb MQuant™ Storage class: 10 - 13 Other liquids and solids Storage: Store at +15°C to +25°C. The lead test is suitable in environmental analysis. Not only in all aqueous media but also…
-
-
UN Number: UN3316 pH: (H2O, 20°C) strongly acid Solubility: (20°C) soluble Density: 1.079 g/cm3 (20°C)
-
Storage: Store at +15°C to +25°C. Precautionary Statement(s): P201: Obtain special instructions before use. P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P308 + P313: IF exposed…
-
Spectroquant® Sulfite Test
MilliporeSigmaMethod: photometric 1.0 - 60.0 mg/l SO3² - 0.8 - 48.0 mg/l SO2
-
-
-
-