Standards, T, GFS Chemicals, Standards
-
AMCO Clear® Turbidity Standard, 900 NTU
GFS ChemicalsTEST Turbidity 900 NTU Absorbance at 455nm (10mm pathlength) Lot Number of Baseline Material
-
Kit contains 0.0 and 40 NTU standards required to calibrate Orbeco-Hellige instruments. The deluxe kit also contains sealed secondary standards of each value.
-
AMCO Clear® Turbidity Standard, 4.0 NTU
GFS ChemicalsTurbidity 4.0 NTU +/- 0.04 Absorbance at 455nm (100mm pathlength) Lot Number of Baseline Material
-
AMCO Clear® Turbidity Standard, 6.0 NTU
GFS ChemicalsTEST Turbidity 6.0 NTU +/- 0.06 Absorbance at 455nm (100mm pathlength) Lot Number of Baseline Material
-
AMCO Clear® Turbidity Standard, 1.0 EBC
GFS ChemicalsTEST Turbidity (Haze) 1.0 EBC +/- 0.05 Absorbance at 455nm (100mm pathlength) Lot Number of Baseline Material
-
Kit contains 0.0 and 1.0 NTU standards required to calibrate the Hach 1720 C, D and E instruments in the low range. The gallon kit also contains a wash bottle and spigots for the bottles.
-
AMCO Clear® Turbidity Standard, 10 NTU for Horiba W-22
GFS ChemicalsTEST Turbidity (on Horiba W-22) 10 NTU Absorbance at 455nm (100mm pathlength) Lot Number of Baseline Material
-
AMCO Clear® Turbidity Standard, 3.0 NTU
GFS Chemicals1. Turbidity 3.0 NTU +/- 0.03 2. Absorbance at 455nm (100mm pathlength) 3. Lot Number of Baseline Material
-
AMCO Clear® Turbidity Standard, 5 EBC
GFS ChemicalsTEST Turbidity (Haze) 5.0 EBC +/-0.1 Absorbance at 455nm (50mm pathlength) Lot Number of Baseline Material
-
TEST Turbidity (on LaMotte 2020) 100 NTU +/-1 Absorbance at 455nm (10mm pathlength) Lot Number of Baseline Material
-
AMCO Clear® Turbidity Standard, 0.8 NTU
GFS ChemicalsFor all EPA 180.1 turbidimeters. TEST Turbidity 0.8 NTU +/- 0.02 Absorbance at 455nm (100mm pathlength) Lot Number of Baseline Material
-
AMCO Clear® Turbidity Standard, 40 NTU for Hach 2100P
GFS ChemicalsTEST Turbidity (on Hach 2100P) 40 NTU Absorbance at 455nm (50mm pathlength) Lot Number of Baseline Material
-
AMCO Clear® Turbidity Standard, 600 NTU
GFS ChemicalsTEST Turbidity 600 NTU +/- 6 Absorbance at 455nm (10mm pathlength) Lot Number of Baseline Material
-
AMCO Clear® Turbidity Standard, 100 NTU for Horiba W-22
GFS ChemicalsTEST Turbidity (Horiba W-22) 100 NTU Absorbance at 455nm (10mm pathlength) Lot Number of Baseline Material
-
TEST Turbidity (on Analite probe) 100 NTU/FNU Turbidity (on ISO 7027 Instrument) 100 FNU Absorbance at 455nm (10mm pathlength) Lot Number of Baseline Material
-
AMCO Clear® Turbidity Standard, 100 NTU for Horiba U-52
GFS ChemicalsTEST Turbidity (on Horiba U-52) 100 NTU Absorbance at 455nm (10mm pathlength) Lot Number of Baseline Material
-
AMCO Clear® Turbidity Standard, 0.5 EBC
GFS ChemicalsTEST Turbidity (Haze) 0.5 EBC +/- 0.05 Absorbance at 455nm (100mm pathlength) Lot Number of Baseline Material
-
TEST Turbidity (on Hach 2100N/AN) 200 NTU Absorbance at 455nm (10mm pathlength) Lot Number of Baseline Material
-
TEST Turbidity (HF Micro 100IR) 10 FNU Absorbance at 455nm (100mm pathlength) Lot Number of Baseline Material
-
Kit contains 0.0, 20, 100 and 800 NTU standards required to calibrate the Hach 2100Q White Light instrument. The deluxe kit also contains sealed secondary standards of each value.
-
AMCO Clear® Wavelength Certification Kit
GFS ChemicalsKit consists of one bottle of 40 NTU primary standard and one bottle of 400 NTU formazin. For all meters with tungsten lamp except Hach 18900, Ratio XR and Ratio 2000. Formazin must be used in 30 days.
-
AMCO Clear® Turbidity Standard, 10 EBC
GFS ChemicalsTEST Turbidity (Haze) 10 EBC +/- 0.1 Absorbance at 455nm (50mm pathlength) Lot Number of Baseline Material
-
TEST Turbidity (Emerson-Rosemount Clarity 2 ISO) 20 NTU Absorbance at 455nm (10mm pathlength) Lot Number of Baseline Material
-
TEST Turbidity (AQ4500) EPA mode Turbidity (AQ4500) IR Ratio mode Thermo Electron AQ4500 serial number Instrument calibration date Formazin Concentrate (4000 NTU) lot number Formazin chec
-
TEST Turbidity (on Hach 2100 N/AN meter) 4000 NTU Absorbance at 455nm (10mm pathlength) Lot Number of Baseline Material
-
TEST Turbidity (AQ4500) EPA mode Turbidity (AQ4500) ISO Neph. mode Turbidity (AQ4500) IR Ratio mode Thermo Electron AQ4500 serial number Instrument calibration date Formazin Concentrate (
-
AMCO Clear® Turbidity Standard, 40 NTU
GFS ChemicalsTurbidity 40 NTU +/- 0.4 Absorbance at 455nm (50mm pathlength) Lot Number of Baseline Material
-
TEST Turbidity (on Analite/ISO 7027 probe) 400 NTU Absorbance at 455nm (10mm pathlength) Lot Number of Baseline Material
-
-
AMCO Clear® Linear Calibration Kit, 0.0/0.1/0.2 NTU
GFS ChemicalsKit contains 0.0, 0.1, 0.2 NTU primary standards to be used to calibrate and verify instrument's linearity in the 0.0 to 0.2 NTU range.
-
AMCO Clear® Turbidity Standard, 0.1 NTU
GFS ChemicalsFor all EPA 180.1 turbidimeters. TEST Turbidity 0.1 NTU +/- 0.02 Absorbance at 455nm (100mm pathlength) Lot Number of Baseline Material
-
AMCO Clear® Turbidity Standard, 5.0 NTU
GFS ChemicalsTurbidity 5.0 NTU +/- 0.05 Absorbance at 455nm (100mm pathlength) Lot Number of Baseline Material