TLC Plates & Sheets, TLC Plates, Plates, MilliporeSigma, Supplies
-
TLC Cellulose F
MilliporeSigmaCellulose plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid…
-
TLC SILICA GEL 60 100 GLASS PLATES 2.5 X 7.5 CM
MilliporeSigmaEMDMilliporeclassical silica TLC plates are based on a combination of proven EMD Milliporesilica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
Synonyms: TLC cards Silica gel
-
PLC Silica Gel 60 F254, 2 mm
MilliporeSigmaPLC plates allow users to separate samples that vary greatly in size – from grams down to milligrams. Available with or without a fluorescence indicator, PLC plates has 2mm thickness. They also use the same proven EMD Millipore silica-binder technology as in analytical TLC plates. To isolate the…
-
TLC SILICA GEL 60 RP-18 F254S 50 GLASS PLATES 5 X 20 CM
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Millipore are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
TLC Silica Gel 60 F254 GLP
MilliporeSigmaThese plates feature individual laser coding for GLP applications. Designed for GLP applications, the tops of each of these plates bear an item, batch, and individual plate number. As a result, lab professionals can easily record and archive every plate they use. Based on proven EMD Millipore…
-
TLC Cellulose
MilliporeSigmaPlates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid derivatives. EMD…
-
-
TLC Silica gel 60 F254 GLP
MilliporeSigmaThese plates feature individual laser coding for GLP applications. Designed for GLP applications, the tops of each of these plates bear an item, batch, and individual plate number. As a result, lab professionals can easily record and archive every plate they use. Based on proven EMD Millipore…
-
TLC SILICA GEL 60 RP-18 F254S 25 GLASS PLATES 20 X 20 CM
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Milliporeare well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
TLC Silica gel 60 RP-2
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Millipore are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
TLC Aluminium Oxide 60 F254, Basic
MilliporeSigmaAluminiumoxide plates are used to analyze basic and neutral compounds at different pH levels. Depending on the pH range in question, professionals can choose between two kinds of aluminum oxide plates. Under aqueous conditions, basic aluminum oxide plates are best for separating basic compounds,…
-
TLC Kieselguhr F254
MilliporeSigmaPrecoated Kieselguhr or mixed Silica gel/Kieselguhr plates are only of small importance nowadays. Kieselguhr layers are used like cellulose layers for the TLC separation of polar and moderately polar substances. Polyamide, on the other hand , is used for the separation of flavonoids and other…
-
HPTLC SILICA GEL 60 DIOL F254S 25 GLASS PLATES 10 X 10 CM
MilliporeSigmaOur NH2, CN and DIOL -modified silica sorbents are less polar then conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative…
-
-
HPTLC LiChrospher® Silica gel 60 RP-18 WF254s
MilliporeSigmaUnique HPTLC Lichrospher® plates are the first thin layer chromatography plates based on spherical silica particles. They offer the ultimate in thin layer chromatography performance and speed enabling high throughput analysis of complex samples. HS Code: 3822 00 00
-
TLC Silica Gel 60 RP-18 F254s
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Millipore are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
HPTLC Silica Gel 60
MilliporeSigmaThese plates deliver fast and quantitative analysis of complex samples for manual or automated use. EMD Millipore’s HPTLC silica plates work three times faster than conventional TLC plates – and they’re more sensitive. The particle sizes range in HPTLC is between 4-8µm, which creates a smoother…
-
HPTLC SILICA GEL 60 RP-18 WF254S 25 GLASS PLATES 10 X 10 CM
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Millipore are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
HPTLC Plates AMD with extra thin layer of only 100µ have been specially developed for even more demanding application such as automated multiple development (AMD). It combines the repeatedly development of the plate in the same direction and reproducible gradient elution. AMD development provides…
-
TLC Cellulose
MilliporeSigmaCellulose plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid…
-
TLC SILICA GEL 60 RP-8 F254S 25 GLASS PLATES 20 X 20 CM
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Milliporeare well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
TLC Silica Gel 60 F254 Multiformat Pre-scored to 5 x 10 cm
MilliporeSigmaPre-scored glass plates fold into smaller formats with just one easy snap of the fingers. HS Code: 3822 00 00
-
-
TLC Silica gel 60 F254
MilliporeSigmaClassic silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to damage the layer.
-
Glass TLC Plates
MilliporeSigmaFor thin layer and preparative layer chromatography Ready-to-use Layer thickness 0.25 mm Allow safe spotting without layer damage Plates have a uniform, abrasion-resistant coating and a patented, inert, hard-layer binder that is chip and abrasion-resistant. F254 is a…
-
HPTLC Silica gel F254 GLP
MilliporeSigmaFeatures individual laser coding for GLP applications. Designed for GLP applications, the tops of each of these plates bear an item, batch, and individual plate number. As a result, lab professionals can easily record and archive every plate they use. Based on proven EMD Millipore silica found in…
-
TLC Silica Gel 60 F254 Multiformat Pre-scored to 5 x 20 cm
MilliporeSigmaThese pre-scored glass plates fold into smaller formats with just one easy snap of the fingers. HS Code: 3822 00 00
-
HPTLC SILICA GEL 60 RP-18 W 25 GLASS PALTES 10 X 20 CM
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Millipore are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…