ICP-MS, Chemicals
-
Torch Injector
Agilent TechnologiesAgilent ICP-OES injectors for fully demountable torches are guaranteed to fit with your Agilent instrument. ICP-OES injectors are available in quartz and alumina with a variety of inner diameters (0.8mm, 1.4mm, 1.8mm, 2.4mm) to meet your application needs. Analysis of organic solvents require…
-
MicroFlow nebulizer PFA 200uL/min., 1/pk
Agilent TechnologiesAgilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
Torch Injector
Agilent TechnologiesAgilent ICP-OES inert torches with alumina/ceramic injectors allow the analysis of samples containg hydrofluoric (HF) acid. HF resistant torches/injectors are suitable for handling HF digests unlike standard quartz injectors where the free HF attacks and degrades the quartz components. Inert…
-
Clamp,torch ball joint connector,1/pk
Agilent TechnologiesAgilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
F0 Encapsulated Micro Capillary
PerkinElmerF0 Encapsulated micro tubing for microflow rates with the lowest internal volume of any nebulizer. Includes 0. 25 mm i. d. (green marker) 70 cm long micro capillary. Compatible with all MEINHARD Plus nebulizers.
-
This kit includes: Demountable Quartz Torch PVDF qty.2 (N8152379) 2.0 mm Demountable Quartz Injector qty.2 (N8152376) Torch Injector Nut qty.2 (N8152451) Glass Cyclonic High Sensitivity Spray Chamber with Matrix Gas Port qty.1 (N8152389) Threaded Spray Chamber Drain Line qty.2 (N8152456) …
-
Concentric Nebulizer
Agilent TechnologiesAgilent nebulizers and supplies are equivalent to the PerkinElmer ICP-MS versions. These parts provide the best precision and reduced interferences, so you can use them with complete confidence. They come complete with the PE gas and liquid connectors for use right out of the box. Application: For…
-
Argon Ferrule
Agilent TechnologiesAgilent nebulizers and supplies are equivalent to the PerkinElmer ICP-MS versions. These parts provide the best precision and reduced interferences, so you can use them with complete confidence. They come complete with the PE gas and liquid connectors for use right out of the box. The GemClean…
-
SeaSpray U-Series Nebulizer 1mL/min
PerkinElmerMaterial: Borosilicate glass High physical reproducibility ~ 1%, TDS tolerance, typically up to 20%, High tolerance to particulates, typically up to 75um, Low RSD's due to highly accurate construction
-
Consumables Kit for ELAN DRC-e/9000
PerkinElmerThis kit includes: ELAN Cross-Flow Nebulizer Tip Kit, Qty. 1 (N8120515) 0-Slot Quartz Torch, Qty. 1 (N8122006) 2.00 mm I.D. Alumina Injector, Qty. 1 (N8126041) Nickel Skimmer Cone, Qty. 2 (WE021137) Nickel Sampler Cone, Qty. 2 (WE021140) Sampler Cone O-Ring, Qty. 5 (WE012687) Series II…
-
The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils. This…
-
Torch for PFA inert kit for ICP-MS, 1/pk
Agilent TechnologiesAgilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
PFA-200 Microflow Nebulizer 20 uL/min
PerkinElmerPFA-200 Microflow Nebulizer, 200 µL/min, with integrated autosampler probe [Ultem support] for ESI SC Autosampler. HF Resistant. Capillary length 150cm. Probe length 175 mm.
-
Nebulizer liquid fitting with ETFE capillary tubing - 4 length by 0. 020 ID x 0. 062 OD flanged onto female CTFE fitting Includes one male barb CTFE fitting.
-
Y connector for pump tubing, ISIS, 5/pk
Agilent TechnologiesAgilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
The MEINHARD concentric glass nebulizers reflect exacting standards in design and manufacturing. They provide excellent sensitivity and precision for aqueous solutions and samples with few dissolved solids (less than 1%). MEINHARD nebulizers for Optima instruments include Standard Nebulizer…
-
Nebulizer Female Barb Fitting
Agilent TechnologiesPerkinElmer, Fitting, female barb, chlorotrifluoroethylene CTFE, for sample inlet fitting used with type A/C/K nebulizers. Suitable for ELAN 9000/6xX00/DRC and NexION. Application: For Sample Inlet Fitting used with Type A/C/K Nebulizers. Suitable for Elan 9000/6Xx00/DRC & NexION This product is…
-
Demountable torch, ICP-MS inert kit 1/pk
Agilent TechnologiesAgilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
-
This one-piece quartz torch, marked blue, with a PVDF o-ring free holder, has a 2.0 mm injector integrated directly into the torch. It's included in the Base Configuration's Sample Introduction Kit (N8150034).
-
-
Baffled Spray Chamber
Agilent TechnologiesThe Agilent Technologies baffled spray chamber has a cyclonic design with a ball joint and the borosilicate glass construction endures heavy impacts. Application: For ELAN DRC/DRC Plus/DRC II, PerkinElmer ICP-MS Instruments This product is only available to U.S. Domestic Customers. For…
-
Torch, quartz 1.5mm inj taper for ICP-MS
Agilent TechnologiesAgilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
This kit includes: 46 cm Copper Refrigeration Tube, Qty. 1 (W1038883) Brass Nut for 3.175 mm Swagelok Tube Fitting, Qty. 2 (WE011094) Brass Back Ferrule for 3.175 mm Swagelok Tube Fitting, Qty. 2 (WE011095) Brass Front Ferrule for 3.175 mm Swagelok Tube Fitting, Qty. 2 (WE011096) Coil Forming…
-
0-Slot Quartz Torch for Optima 8x00
PerkinElmerDemountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…
-
This kit includes: Glass Standard Cyclonic Spray Chamber (N0776052) Cyclonic Spray Chamber Mount Kit (N0770131) Cyclonic Spray Chamber Mount Nut (N0776005) Cyclonic Spray Chamber Mount Sleeve (N0776004) Cyclonic Spray Chamber Mount Ring (N0776003) 20 mm M4 Cap Screw (09919167) 6 mm M3 Cap…
-
Solution fitting, 0.5 mm PTFE with adapter F2-50
PerkinElmerSolution fitting, 0.5 mm PTFE with adapter F2-50
-
Nebulizer Sample Capillary
Agilent TechnologiesAgilent nebulizers and supplies are equivalent to the PerkinElmer ICP-MS versions. These parts provide the best precision and reduced interferences, so you can use them with complete confidence. They come complete with the PE gas and liquid connectors for use right out of the box. Application:…
-
ICP-OES Nebulizers
Agilent TechnologiesAgilent offers a wide range of concentric and microconcentric glass nebulizers to facilitate sample introduction for a variety of ICP-OES measurements. Nebulizer styles can accommodate samples with up to 20% total dissolved solids (TDS) and slurry samples containing more than 20% total dissolved…
-
Adjustable Torch Mount Assembly for Avio 200
PerkinElmerThe adjustable torch mount assembly is included in the Adjustable Torch Body Assembly (N0790138). This assembly includes: Torch Mount, Qty 1. (N0791285) Disk Magnet, Qty. 1 (09200515)
-
GemCone High Dissolved Solids Nebulizer
PerkinElmerHigh solids Gem Cones are for samples with high dissolved solids (up to 20%). This cone spray nebulizer allows you to analyze samples with higher solids concentration than is possible with a Cross-Flow nebulizer. Gem Cone nebulizers require an end cap for use with Ryton Scott Spray Chambers. High…
-
Spray Chamber Connector
Agilent TechnologiesThe Agilent Technologies spray chamber connector is made from EzyLok technology that helps in preventing any kind of penetration and is used with jacketed spray chamber. Application: For Jacketed Spray Chamber. Suitable for PerkinElmer ICP-MS This product is only available to U.S. Domestic…