  • Fixed 2.5 mm I.D. Injector Quartz Torch (Green Mark) for NexION 2000/1000

    PerkinElmer

    This one-piece quartz torch, marked blue, with a PVDF o-ring free holder, has a 2.0 mm injector integrated directly into the torch. It's included in the Base Configuration's Sample Introduction Kit (N8150034).

  • Quartz Torch O-Ring Kit for Optima 2x00/4x00/5x00/7x00 DV

    PerkinElmer

    This kit includes: O-Ring 29.74 mm I.D., Qty. 1 (09902131) O-Ring 20.3 mm I.D., Qty. 2 (09902223) O-Ring 28.17 mm I.D., Qty. 1 (09921061) O-Ring 26.57 mm I.D., Qty. 1 (09921062) O-Ring 20.3 mm I.D., Qty. 1 (09902045)

  • 3-Slot Quartz Torch for Optima 8x00

    PerkinElmer

    Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…

  • Torches and Components

    Agilent Technologies

    Comprised of three Concentric Quartz tubes through which streams of argon gas pass. Three streams = plasma, auxiliary, and nebulizer (carrier) gas.

  • 1-Slot HybridXLT Ceramic-Quartz Torch for Optima 8x00

    PerkinElmer

    PerkinElmer's HybridXLT torch is the latest addition to the family of PerkinElmer genuine sample introduction components. The new ceramic/quartz hybrid design provides the highest performance for your Optima ICP-OES 8x00 spectrometer. This new torch has an extended lifetime of up to 10x your…

  • 1-Slot Quartz Torch for Optima 2x00/4x00/5x00/7x00 DV

    PerkinElmer

    Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…

  • Silicone Torch O-Ring, 9.25 mm I.D. for Optima 3x00 XL/3x00 DV/3000 SCX/4300…

    PerkinElmer

    Silicone o-ring, 9.25 mm inner diameter by 1.8 mm width, used with quartz torches in Optima 3x00 XL, 3x00 DV, 3000 SCX, 4300 V, 5300 V, and 7300 V ICP-OES series instruments.

  • Self-Aligning RF Load Coil Assembly for NexION 300/350 & ELAN 6x00/9000/DRCs

    PerkinElmer

    This kit includes: 46 cm Copper Refrigeration Tube, Qty. 1 (W1038883) Brass Nut for 3.175 mm Swagelok Tube Fitting, Qty. 2 (WE011094) Brass Back Ferrule for 3.175 mm Swagelok Tube Fitting, Qty. 2 (WE011095) Brass Front Ferrule for 3.175 mm Swagelok Tube Fitting, Qty. 2 (WE011096) Coil Forming…

  • Axial Purge Extension Window for Optima 2x00/3000 SCX/3x00 XL/7000/8000

    PerkinElmer

    The Axial View Purge Extension Window is a replaceable quartz window that slides into the purge extension between the torch and the optics. The Radial View Purge Extension Window Tube is a replaceable quartz Tube that slides into the mount between the torch and the optics for the radial view.

  • Copper Torch Ignitor Tape for Optima 8x00

    PerkinElmer

    Part of the Cyclonic/Concentric Kit 8x00 which includes: 1 Slot Quartz Torch, 2.0 mm i.d. Alumina Injector, Glass Cyclonic Spray Chamber, Meinhard ® Type K1 Nebulizer, Quartz Torch Copper Ignitor Tape – Qty. 50 pcs.

  • Torch O-Ring Kit for Optima 8x00

    PerkinElmer

    This kit includes: O-Ring 29.74 mm I.D., Qty. 1 (09902131) O-Ring 20.3 mm I.D., Qty. 2 (09902223) O-Ring 28.17 mm I.D., Qty. 1 (09921061) O-Ring 26.57 mm I.D., Qty. 1 (09921062) Silicone Super-O-Lube, 2 grams (09200078)

  • 1-Slot Quartz Torch for Optima 8x00

    PerkinElmer

    Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…

  • Consumables Kit for ELAN DRC II

    PerkinElmer

    This kit includes: 2 mm I.D. Quartz Bore Injector, Qty. 1 (WE023948) Platinum Sampler Cone, Qty. 1 (WE027802) Platinum Skimmer Cone, Qty. 1 (WE027803) 0-Slot Quartz Torch, Qty. 1 (N8122006) Sampler Cone O-Ring, Qty. 5 (WE012687) Series II Replacement Lens, Qty. 1 (WE018034) RF Load Coil…

  • 3-Slot HybridXTL Organics Quartz Torch for Avio 200/500

    PerkinElmer

    Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…

  • Scott/Cross-Flow Sample Introduction Module for Optima 2x00/4x00/5x00/7x00 DV

    PerkinElmer

    This module kit includes: Inner Chamber for External Ryton/Type II Spray Chamber, Qty. 1 (N0582258) Outer Axial Spray Chamber, Qty. 1 (N0775296) 1-Slot Quartz Torch, Qty. 1 (N0770338) GemTip Cross-Flow II Nebulizer, Qty. 1 (N0770546) 2.0 mm I.D. Alumina Injector (N0775177) Quick-Change Torch…

  • Axial One Piece Torches

    Agilent Technologies

    Agilent's ICP-OES series are compatible with a range of accessories and supplies designed to extend the capabilities of the instruments. Agilent's torches light easily and stay lit, reducing downtime.

  • Silicone Torch O-Ring, 6.07 mm I.D. for Optima 3x00 XL/3x00 DV/3000 SCX

    PerkinElmer

    Silicone o-ring, 6.07 mm inner diameter by 1.8 mm width, used with torches in Optima 3x00 XL, 3x00 DV, and 3000 SCX ICP-OES series instruments.

  • Cyclonic/Concentric Sample Introduction Module for Optima 2x00/4x00/5x00/7x00 DV

    PerkinElmer

    This kit includes: MEINHARD Type C Concentric Glass Nebulizer, Qty. 1 (00472022) 1-Slot Quartz Torch, Qty. 1 (N0770338) Cyclonic Spray Chamber Assembly, Qty. 1 (N0770605) Quick-Change Torch Module Mounting Block, Qty. 1 (N0770600) 2.0 mm I.D. Alumina Injector (N0775177) Nebulizer Tubing…

  • Copper Torch Ignitor Tape for Optima 2x00/4x00/5x00/7x00 DV

    PerkinElmer

    The roll of tape includes 120 pieces.

  • Consumables Kit for NexION 2000 Semiconductor Configuration

    PerkinElmer

    This kit includes: Fixed 2.0 mm Injector UHP Quartz Torch qty.2 (N8152428) Torch Injector Nut qty.2 (N8152451) SilQ Cyclonic High Sensitivity Spray Chamber qty.1 (N8152424) Threaded Spray Chamber Drain Line qty.2 (N8152456) Platinum Skimmer Cone qty.2 (W1026907) Platinum Sampler Cone qty.2…

  • O-Ring Free Quartz Torch for ELAN 5000/6x00/9000/DRCs & NexION 300/350

    PerkinElmer

    Demountable quartz torch for o-ring-free injectors. Use with ESI o-ring-free injectors.

  • 0-Slot High Efficiency Quartz Torch Installation Kit for ELAN 6x00/9000

    PerkinElmer

    Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. The torch operates at 25% reduced argon gas flows compared to the standard demountable quartz torch (N8122006). This kit is required for first-time installation of the high efficiently quartz torch for ELAN 9000 and…

  • 1-Slot Quartz Torch for Optima 3x00 DV

    PerkinElmer

    Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…

  • Adjustable Torch Mount Assembly for ELAN 9000/DRC-e

    PerkinElmer

    The Cassette Torch Mount is an innovative torch design that is fully modular, demountable, rugged and easy to maintain.

  • Demountable SilQ Torch (Grey Mark) for NexION 2000

    PerkinElmer

    This demountable quartz torch, marked grey, allows for the use of different injectors depending on the application. A PVDF O-ring free holder is included.

  • 3-Slot Quartz Torch for Optima 4300/5300/7300 V

    PerkinElmer

    Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…

  • Consumables Kit for NexION 2000 Base Configuration

    PerkinElmer

    This kit includes: Fixed 2.0 mm Injector Quartz Torch (Blue Mark) qty.2 (N8152472) Torch Injector Nut qty.2 (N8152451) Glass Cyclonic High Sensitivity Spray Chamber qty.1 (N8152375) Threaded Spray Chamber Drain Line qty.2 (N8152456) Nickel Skimmer Cone qty.2 (W1026356) Nickel Sampler Cone…

  • Consumables Kit for NexION 2000 Productivity Configuration

    PerkinElmer

    This kit includes: Demountable Quartz Torch PVDF qty.2 (N8152379) 2.0 mm Demountable Quartz Injector qty.2 (N8152376) Torch Injector Nut qty.2 (N8152451) Glass Cyclonic High Sensitivity Spray Chamber with Matrix Gas Port qty.1 (N8152389) Threaded Spray Chamber Drain Line qty.2 (N8152456) …

  • 0-Slot Quartz Outer Tube for ELAN 5000/6x00/9000/DRCs & NexION 300/350 D-Torch

    PerkinElmer

    The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils.

  • 3-Slot Quartz Outer Tube for Optima 4300/5300/7300 V D-Torch

    PerkinElmer

    The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils.

  • Organics Sample Introduction Kit for Optima 8x00

    PerkinElmer

    This kit includes: 3-Slot Quartz Torch, Qty. 2 (N0780132) 1. 2 mm I.D. Alumina Injector, Qty. 2 (N0781007) Baffled Cyclonic Spray Chamber 4 mm, Qty. 1 (N0776090) GemCone ™ Low-Flow Nebulizer, Qty. 1 (N0770358) Cyclonic Spray Chamber Adapter, Qty. 1 (N0770614) Injector Adapter Washer, Qty. 1…

  • Torch Injector Nut for NexION 2000/1000

    PerkinElmer

    Two Torch Injector Nuts are included in the NexION 2000 ICP-MS Base Configuration's Consumable Kit (N8150054), Core Configuration's Consumable Kit (N8150055), Productivity Configuration's Consumable Kit (N8150056), and Semi Configuration's Consumable Kit (N8150057). One is also included in the…