Columns, YMC, General Chromatography Columns, Chemicals

Compare Tool

Select up to 3 products

Sort
View
Show
  • YMC-Actus series are semi-preparative HPLC columns that have excellent column durability and efficiency by applying axial compression technology. YMC-Actus series columns show high durability under high flow rate or steep gradient conditions and desirable for milligram scale preparative HPLC of…

  • ODS-AQ is a unique reversed-phase material with both a hydrophobic high carbon loading and a relatively hydrophilic surface. Because of the hydrophilic surface, ODS-AQ can be "wetted" with polar eluents. ODS-AQ provides chromatographers reproducible retention and excellent peak shape in highly…

  • In a reversed-phase mode, Cyano columns are the most polar and least retentive of all reversed-phase packings. Extremely hydrophobic compounds, which do not elute on standard C18 and C8 packings with typical reversed-phase eluents, can be chromatographed using Cyano columns. In addition, the unique…

  • YMC-Pack Polyamine II is a silica-based packing bonded with polyamine. It is particularly useful for separation of sugars. The column life of YMC-Pack Polyamine II in aqueous mobile phase is longer than conventional silica-based amino columns, and thus is applicable to separation of…

  • The choice of columns for analysis of difficult compounds by HPLC YMC-Pack Pro C18 columns start with a tightly controlled, highly purified silica gel, followed by a high-coverage C18 bonding and finish with a unique endcapping procedure utilizing Lewis acid-Lewis base chemistry. 2 µm particle size…

  • ODS-AM is a high carbon load C18 packing that is similar in selectivity to ODS-A. The major difference between these bonded phases is that ODS-AM has extremely tight specification criteria which provides excellent peak shape and more reproducible separation. Application: For Alkaloids Long-term…

  • ODS-A in 120Å pore size is the first choice of many chromatographers for high performance reversed phase separations. It has selectivity for the separation of a wide range of organic compounds found in pharmaceutical, chemical and biotechnology industries. ODS-A is a high coverage, fully endcapped…

  • ODS-AM is a high carbon load C18 packing that is similar in selectivity to ODS-A. The major difference between these bonded phases is that ODS-AM has extremely tight specification criteria which provides excellent peak shape and more reproducible separation. Application: For Alkaloids Long-term…

  • YMC-Pack C4 (Butyl) columns are less hydrophobic than C8 or C18 packings, and generally utilize more aqueous eluents than either of these reversed phase column types. When compared to C8 and C18 columns using the same eluent, C4 columns show significantly shorter retention for non-polar compounds.…

  • Pro C18 RS has excellent peak shape for the separation of basic compounds because of high quality end capping. Pro C18 RS has high recognition of stereoselectivity because of high carbon polymeric type bonding. Pro C18 RS can be used over a wide pH range (1-10) to aid in method development. High…

  • YMCbasic is a unique reversed-phase column designed for analysis of pharmaceuticals and other basic compounds. YMCbasic utilizes a novel silica synthesis and state-of-art silane bonding to create a column which gives true reversed-phase character, high resolution and excellent peak shape for the…

  • C8 is the most commonly used column type following C18. YMC Octyl columns are prepared from exhaustive bonding of a monomeric octylsilane to totally spherical and porous silica gels. The functionalized silica is then treated with a endcapping process. Application: For Anti-Human Immunodeficiency…

  • YMC-Triart C8 is a versatile column with excellent chemical durability that is equivalent to YMC-Triart C18. YMC-Triart C8 is suitable for fast analysis of samples containing hydrophobic compounds that are strongly retained on C18 columns or samples containing compounds with large differences in…

  • J'sphere offers a choice from three kinds of ODS made from the same silica gel base, each with different ligand coverage. Differences in ligand coverage considerably affect the hydrophobic retention behavior of solutes, as well as the separation behavior resulting from solute functional groups or…

  • Hydrosphere C18 is designed to maintain adequate hydrophilicity on the packing surface for superior separation of hydrophilic compounds. Hydrophilic compounds are retained with much greater affinity than with conventional ODS columns, permitting the product to be used with 100% water eluent, a…

  • J'sphere offers a choice from three kinds of ODS made from the same silica gel base, each with different ligand coverage. Differences in ligand coverage considerably affect the hydrophobic retention behavior of solutes, as well as the separation behavior resulting from solute functional groups or…

  • Handy connector 2 resists pressure to ca. 42 MPa. Handy connector 2 is suitable for connection to the injection side of a column, to which high pressure is applied. It is also useful for connection of a guard column or a precolumn filter. Be aware that Handy connector 2 cannot be connected to"…

  • Pro C18 RS has excellent peak shape for the separation of basic compounds because of high quality end capping. Pro C18 RS has high recognition of stereoselectivity because of high carbon polymeric type bonding. Pro C18 RS can be used over a wide pH range (1-10) to aid in method development. …

  • PolymerC18 is a C18 column made from methacrylate polymer. It has excellent pH stability and it is useful for separation of basic compounds because there are no silanol or metal impurities to cause secondary interaction. Since p electrons of the carbonyl group or the hydroxyl group on the surface…

  • J'sphere offers a choice from three kinds of ODS made from the same silica gel base, each with different ligand coverage. Differences in ligand coverage considerably affect the hydrophobic retention behavior of solutes, as well as the separation behavior resulting from solute functional groups or…

  • In a reversed-phase mode, Cyano columns are the most polar and least retentive of all reversed-phase packings. Extremely hydrophobic compounds, which do not elute on standard C18 and C8 packings with typical reversed-phase eluents, can be chromatographed using Cyano columns. In addition, the unique…

  • YMC-Triart C18 is a hybrid silica-based ODS column emphasizing durability, low operating pressure, and excellent performance. YMC-Triart C18 has been developed and is manufactured using state-of-the-art technologies that define materials, granulation, and surface modification. Long column…

  • The choice of columns for analysis of difficult compounds by HPLC YMC-Pack Pro C18 columns start with a tightly controlled, highly purified silica gel, followed by a high-coverage C18 bonding and finish with a unique endcapping procedure utilizing Lewis acid-Lewis base chemistry. 2 µm particle size…

  • YMC-Triart C8 is a versatile column with excellent chemical durability that is equivalent to YMC-Triart C18. YMC-Triart C8 is suitable for fast analysis of samples containing hydrophobic compounds that are strongly retained on C18 columns or samples containing compounds with large differences in…

  • All phases in the Pro-family are ideal for the analysis of all types of organic molecules but specifically basic and metal chelating compounds. The ultrapure silica and very low residual silanol activity means that these columns frequently do not require the use of ion-pairing reagents or…

  • C8 is the most commonly used column type following C18. YMC Octyl columns are prepared from exhaustive bonding of a monomeric octylsilane to totally spherical and porous silica gels. The functionalized silica is then treated with a endcapping process. Application: For Anti-Human Immunodeficiency…

  • The high purity silica found in YMC-Pack Silica columns provides virtually complete sample recovery. The absence of silica impurities reduces non-specific sample adsorption which lowers sample recovery and may cause unusual peak shapes. The totally porous nature of the silica found in YMC-Pack…

  • YMC-Pack TMS columns are bonded with trimethylmonochlorosilane to create a phase with intermediate polarity for analysis of extremely hydrophobic compounds using conventional reversed-phase solvents and highly polar compounds using highly aqueous solvents. The unique chemistry of TMS is also…

  • YMC-Pack C4 (Butyl) columns are less hydrophobic than C8 or C18 packings, and generally utilize more aqueous eluents than either of these reversed phase column types. When compared to C8 and C18 columns using the same eluent, C4 columns show significantly shorter retention for non-polar compounds.…

  • A stainless steel tube with a screw and an endfitting are directly connected (screw type). Since YMC original empty columns use no ferrule, there is no danger of endfitting dislocation when the column is packed and used under high pressure.

  • All phases in the Pro-family are ideal for the analysis of all types of organic molecules but specifically basic and metal chelating compounds. The ultrapure silica and very low residual silanol activity means that these columns frequently do not require the use of ion-pairing reagents or…

  • All phases in the Pro-family are ideal for the analysis of all types of organic molecules but specifically basic and metal chelating compounds. The ultrapure silica and very low residual silanol activity means that these columns frequently do not require the use of ion-pairing reagents or…

Compare Tool

Select up to 3 products