Columns, PerkinElmer, Nucleic Acid Sample Preparation, Gas Chromatography Columns
-
Elite-17ms columns are for confirmation analysis and have excellent inertness for active compounds
-
Elite-5 capillary column, 30m x 0.32mm, 0.25µm
PerkinElmerEquivalent to USP G27 and G36 phases Temperature range -60°C to 350°C
-
Elite-WAX capillary column 15m x 0.45mm, 0.42µm
PerkinElmerTemperature range 20oC to 250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
Elite-5ht capillary column 30m x 0.25mm, 0.10µm
PerkinElmerTemperature range -60 o C to 400 o C. Equivalent to USP G27, G36 phases.
-
Elite-1 capillary column, 30m x 0.53mm, 1.50µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite-1 capillary column, 15m x 0.25mm, 0.25µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite-1 capillary column, 15m x 0.32mm, 3.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite 624 capillary column 30m x 0.53mm, 3.00µm
PerkinElmerTemperature range -20°C to 240°C Equivalent to USP G43 phase
-
Deactivated Tubing is perfect for making guard columns and retention gaps. Use Splitters(p/n N9303448) and connectors (p/n N9302149) to attach tubing to polymide coated columns.
-
Temperature range -60°C to 320/340°C.
-
Elite-1 capillary column, 15m x 0.32mm, 0.25µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Temperature range -20°C to 240/260°C.
-
The Elite-SimDist columns are specifically for the simulated distillation application. The phase is specifically processed for dimethylpolysiloxane.
-
Elite 624 capillary column 60m x 0.25mm, 1.40µm
PerkinElmerTemperature range -20°C to 240°C Equivalent to USP G43 phase
-
-
Elite 1301 capillary column 10m x 0.18mm, 0.40µm
PerkinElmerTemperature range -20°C to 280°C Equivalent to USP G43 phase
-
-
Temperature range -60°C to 300/315°C.
-
Temperature range -60°C to 300/315°C.
-
Polyimide Uncoated Deactivated Fused Silica Capillary Tubing comes in a standard length of 5 meters.
-
Elite-1 capillary column, 15m x 0.25mm, 0.10µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite-1 capillary column, 60m x 0.32mm, 1.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
PerkinElmer's new line of Velocity fused silica columns yield exceptional performance for general GC applications without the cost associated with GC/MS analysis. Designed to offer quality, affordability with reproducible results, comparable to Agilent, Supelco, Restek, SGE and Varian GC columns…
-
Elite-5MS capillary column 60m x 0.32mm, 0.25µm
PerkinElmerTemperature range -60oC to 350 oC Equivalent to USP G27, G36 phases
-
Elite-200 capillary column 30m x 0.53mm, 3.00µm
PerkinElmerEquivalent to USP G6 phase. Temperature range -20°C to 260/280°C.
-
Elite-17 capillary column, 20m x 0.18mm, 0.18µm
PerkinElmerEquivalent to USP G3 phase Temperature range 40°C to 320°C
-
Elite-200 capillary column 60m x 0.32mm, 1.00µm
PerkinElmerEquivalent to USP G6 phase. Temperature range -20°C to 290/310°C.
-
-
Elite 608 capillary column 75m x 0.32mm, 0.50µm
PerkinElmerThermally stable to 340°C Low column bleed - ideally suited for ECD and GC/MS analysis
-
Elite-WAX capillary column 30m x 0.32mm, 0.50µm
PerkinElmerTemperature range 20oC to 250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
COL-Elite 1 30 m, 0.25 mm ID, 0.25
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite 624 capillary column 30m x 0.32mm, 1.80µm
PerkinElmerTemperature range -20°C to 240°C Equivalent to USP G43 phase