PerkinElmer Gas Chromatography Columns
-
Elite-35ms capillary column 25m x 0.20mm, 0.33µm
PerkinElmerEquivalent to USP G42 phase Temperature range 40°C to 340°C/360°C
-
The PerkinElmer Elite-502.2 Series of capillary columns are specifically designed for the analysis of volatiles by US EPA method 502.2. The low polarity phase is a proprietary dimethyl-diphenyl polysiloxane bonded phase.
-
Temperature range -60oC to 200 oC
-
Elite-5 capillary column, 30m x 0.32mm, 0.25µm
PerkinElmerEquivalent to USP G27 and G36 phases Temperature range -60°C to 350°C
-
Temperature range -60°C to 300/315°C.
-
Elite-WAX capillary column 30m x 0.32mm, 0.50µm
PerkinElmerTemperature range 20oC to 250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
Elite-1 capillary column 60m x 0.32mm, 1.50µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases. Temperature range -60°C to 310/330°C.
-
Elite-5ht capillary column 30m x 0.25mm, 0.10µm
PerkinElmerTemperature range -60 o C to 400 o C. Equivalent to USP G27, G36 phases.
-
-
Elite-1 capillary column, 15m x 0.32mm, 3.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
The Elite-SimDist columns are specifically for the simulated distillation application. The phase is specifically processed for dimethylpolysiloxane.
-
COL-Elite 1 30 m, 0.25 mm ID, 0.25
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Temperature range -20°C to 240/260°C.
-
Elite-200 capillary column 30m x 0.32mm, 0.25µm
PerkinElmerEquivalent to USP G6 phase. Temperature range -20°C to 320/340°C.
-
Elite-1ht capillary column 30m x 0.25mm, 0.10µm
PerkinElmerTemperature range -60 o C to 400 o C. Equivalent to USP G1, G2, G38 phase.s.
-
Elite-1 capillary column, 30m x 0.25mm, 1.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite-200 capillary column 30m x 0.53mm, 3.00µm
PerkinElmerEquivalent to USP G6 phase. Temperature range -20°C to 260/280°C.
-
Elite 624 capillary column 30m x 0.32mm, 1.80µm
PerkinElmerTemperature range -20°C to 240°C Equivalent to USP G43 phase
-
Elite-WAX capillary column 60m x 0.45mm, 0.85µm
PerkinElmerTemperature range 20oC to 240/250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
Refinery Gas Analyzer Calibration Blend without Syringe Adapter
-
Elite-1 capillary column, 15m x 0.25mm, 1.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite-5MS capillary column 60m x 0.32mm, 0.25µm
PerkinElmerTemperature range -60oC to 350 oC Equivalent to USP G27, G36 phases
-
PerkinElmer Elite-XLB (Specialty phase for GC/MS with exceptionally low bleed) Series Capillary Columns, Length: 30m, Inner Diameter: 0.32mm, Film Thickness: 0.50m, Temperature Limits:30 to 340/360C
-
Elite-1 capillary column, 30m x 0.53mm, 1.50µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Deactivated Tubing is perfect for making guard columns and retention gaps. Use Splitters(p/n N9303448) and connectors (p/n N9302149) to attach tubing to polymide coated columns.
-
-
-
Elite-Siltek Guard, 5m x 0.32mm
PerkinElmerElite-Siltek Guard Columns lengthen the life of the capillary columns.
-
Empty Columns for all your Gas Chromatography equipment come in multiple sizes and are able to fit a variety of different systems.
-
Elite 1301 capillary column 30m x 0.25mm, 0.25µm
PerkinElmerTemperature range -20°C to 280°C Equivalent to USP G43 phase
-
Elite-WAX capillary column 15m x 0.45mm, 0.42µm
PerkinElmerTemperature range 20oC to 250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
Elite-17ms columns are for confirmation analysis and have excellent inertness for active compounds