Columns, NEW! Life Science, Gas Chromatography Columns
-
Reservoir for use with CG-1199 and CG-1200 columns. Reservoir has a top 35/20 socket joint for use with CG-1201 flow control adapter and the listed size lower ball joint.
-
General purpose column having a PTFE stopcock, reservoir of the listed capacity and a top spherical socket joint. Glass wool (not supplied) is used to support the column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described…
-
Inlet Ferrules, 100% PTFE
Chromatography Research SuppliesThomas Scientific offers a large selection of ferrules made from PTFE, Graphite, Vespel® and Vespel/Graphite composites. Ferrule sizes refer to the size of the fittings into which they fit; they are not the diameter of the ferrule. (For example, 1/16" ferrules are 1/8" diameter.) …
-
Similar to CG-1186 but with a sealed in COARSE porosity fritted disc to support column packing. Lower end of the column has a round bottom. Column is constructed using MEDIUM WALL TUBING.
-
3x faster multiresidue pesticides analysis in foods. Factory-coupled, leak-free kit makes setting up LPGC as simple as a column change. Ideal for speeding up GC-MS and GC-MS/MS methods. Integrated transfer line reduces background and stabilization time.
-
-
DB-1ht
Agilent Technologies100% Dimethylpolysiloxane Non-polar Specially processed for extended temperature limit of 400°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Bonded and cross-linked Solvent rinsable …
-
Capillary Column Ferrules
Agilent TechnologiesCapillary ferrules are packaged in dial packs which deliver one ferrule at a time, keeping the others clean and ready for use. The dial packaging has been tested to ensure no out gassing of contaminants, including phthalates. *These ferrules are recommended for use with Agilent GC/MS…
-
HP-INNOWax GC Columns
Agilent TechnologiesHP-INNOWax is a polyethylene glycol (PEG) stationary phase that features high polarity and high upper temperature limits. It is a close equivalent to USP phase G16 and is targeted at food, flavor, and fragrance applications. The improved line of Agilent J&W HP-INNOWax GC columns utilizes…
-
Accurate quantification of toluene and benzene—including benzene in gasoline containing ethanol or butanol blends. Complete resolution of benzene from ethanol—no compromising coelutions. Enhanced formulation with improved support material and polymers—more robust and reproducible. Column sets…
-
Elite 624 capillary column 30m x 0.25mm, 1.40µm
PerkinElmerTemperature range -20°C to 240°C Equivalent to USP G43 phase
-
Chemists using guard columns in the analyses of basic compounds frequently observe peak tailing and low recovery. This happens because conventionally deactivated tubing surfaces can be adsorptive to basic compounds. Restek offers base-deactivated guard columns, as well as base-deactivated inlet…
-
HYDRODEX Capillary Columns
MACHEREY-NAGELHYDRODEX cyclodextrin phases Capillary columns for GC enantiomer separation Features Base material: cyclic oligosaccharides consisting of seven (β-cyclodextrin) or eight (γ-cyclodextrin) glucose units bonded through α-1,4-linkages Regioselective derivatization…
-
Press-Fit Capillary Column Connectors
Agilent TechnologiesIn the past it was necessary to use Press-fit connectors with specific dimensions to connect columns of those dimensions. Modern Press-fit connectors are “laser-milled” to provide highly reproducible taper angles throughout the length of the Press-fit insuring an excellent seal. Now the…
-
Elite-1 capillary column, 15m x 0.53mm, 3.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
low-polarity phase; Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to…
-
Deactivated capillary columns (precolumns)
MACHEREY-NAGELRecommended application: Preparation of capillary columns As precolumns, whenever a larger contamination capacity is required Different deactivations are available: Methyl-Sil deactivated Phenyl-Sil deactivated CW deactivated
-
Cyclosil-B
Agilent Technologies30% heptakis (2,3-di-O-methyl-6-O-t-butyl dimethylsilyl)-β -cyclodextrin in DB-1701 Chiral separations without chiral specific derivatization New stationary phase for improved resolution of many chiral separations Suitable for many chiral γ -lactones and terpenes Similar…
-
SLB®-5ms Capillary GC Column
MilliporeSigmaApplication: The 5% phenyl equivalent phase provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. The low bleed characteristics, inertness, and durable nature make it the column of choice for environmental analytes (such as semivolatiles,…
-
-
-
In packed columns, the carrier gas percolates through the porous bed. In a packed column, separation is achieved by moving the solutes apart. Packed columns are made up of two main materials; stainless steel and Pyrex glass. Metal packed columns are more suitable for long and high carrier gas flow…
-
Temperature range -60°C to 300/315°C.
-
-
DB-Wax
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity …
-
Untreated Capillaries
MACHEREY-NAGELUntreated capillaries Recommended application: Capillary electrophoresis Preparation of capillary columns Capillary LC applications
-
5% diphenyl, 95% dimethyl polysiloxane Optimized for PBDE analysis by EPA Method 1614. Short column option resolves BDE-209 3 times faster, with less thermal breakdown. Unique deactivation gives higher BDE-209 response than competitor columns, for greater analytical sensitivity. …
-
Elite-1 capillary column, 40m x 0.18mm, 0.40µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
-
PerkinElmer's new line of Velocity fused silica columns yield exceptional performance for general GC applications without the cost associated with GC/MS analysis. Designed to offer quality, affordability with reproducible results, comparable to Agilent, Supelco, Restek, SGE and Varian GC columns…
-
Glass Empty Column, 2mm i.d., 1/4in o.d., 3 ft for AutoSystem GC (on column)
-
DB-5 And DB-5ms
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-5 (2713R99, T86, T94 and V89) (5%-Phenyl)-methylpolysiloxane Non-polar …