Gas Chromatography Columns, Columns, GC

Compare Tool

Select up to 3 products

HomeAll Products

GC Columns Gas Chromatography Columns

65 - 96 of 98
Sort
View
Show
  • Agilent Technologies

    DX-1: 90% Dimethylpolysiloxane - 10% Polyethylene Glycol DX-4: 15% Dimethylpolysiloxane - 85% Polyethylene Glycol Because DX series GC columns are not bonded and cross-linked, we do not recommend solvent rinsing. Agilent Technologies products are intended for sale/shipment within…

  • Agilent Technologies

    (35% Trifluoropropyl)-methylpolysiloxane 300/320°C temperature limit Midpolarity (more polar than DB-1701 or DB-17) Ideal for difficult to separate positional isomers Unique interactions with compounds containing nitro, halogen and carbonyl groups Low ECD bleed …

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-1301: (6%-Cyanopropyl-phenyl) methylpolysiloxane DB-1301: Equivalent to USP…

  • Agilent Technologies

    Low polarity stationary phase Resolves MTBE from 2-methylpentane and 3-methylpentane for better quantitation Engineered for purge and trap injection without the need for cryofocusing Bonded and cross-linked Solvent rinsable Agilent Technologies products are intended for…

  • Agilent Technologies

    Excellent inertness Virtually unbreakable Available in a wide variety of stationary phases Bonded and cross-linked Ideal for high temperature analysis and process applications Our asy to handle DB-ProSteel metal columns are deactivated with a new formula (this is not glass lined steel)…

  • Agilent Technologies

    Non-polar Specifically designed and processed for the analysis of organochlorine pesticides ECD tested to assure minimal pesticide breakdown and low ECD bleed Bonded and cross-linked Solvent rinsable Similar Phases: DB-5, Ultra-2, SPB-5, CP-Sil 8CB, RSL-200, Rtx-5, BP-5,…

  • Polyethylene glycol (PEG) High polarity Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes Column-to-column repeatability Bonded and cross-linked; solvent rinsable Agilent Technologies products are…

  • (5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limit Bonded and cross-linked; solvent rinsable Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies…

  • Agilent Technologies

    Polyethylene glycol, MW 20,000 Equivalent to USP Phase G16 Similar Phases: DB-WAX, HP-INNOWax, DB-WAXetr Because the Carbowax 20M and the HP-20M are not bonded or cross-linked, we do not recommend solvent rinsing. DB-WAX is the recommended bonded alternate for the HP-20M. …

  • Equivalent to (5%-Phenyl)-methylpolysiloxane Non-polar Specially processed to exhibit excellent inertness for EPA Semivolatile Methods 625, 1625, 8270 and CLP protocols Surpasses EPA performance criteria for semi-volatiles Inert and neutral for base, neutral and acidic compounds High…

  • Agilent Technologies

    Specifically engineered for the analysis of polychlorinated dibenzodioxins (PCDDs) and dibenzofurans (PCDFs) Resolves 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in one run Low bleed Bonded and cross-linked Solvent rinsable Similar Phases: SP-2331, 007-23,…

  • Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Reliable blood alcohol analysis Excellent confirmation column with DB-ALC2 for…

  • Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Non-polar Excellent general purpose column -…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Nitroterephthalic acid modified polyethylene glycol High polarity Temperature…

  • GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Equivalent to USP Phase G43 Thinner film reduces run time by 2.5 times and…

  • The DB-1ms is a non-polar, low bleed column with excellent inertness for acids/bases and an extended upper temperature limit. Using low bleed stationary phases reduces the column contribution to background noise resulting in a higher signal to noise ration and better sensitivity. The reduced column…

  • (5%-Phenyl)-methylpolysiloxane Non-polar Low bleed characteristics, ideal for GC/MS First-rate inertness for active compounds including acidic and basic compounds Improved signal-to-noise ratio for better sensitivity and mass spectral integrity Bonded and cross-linked; solvent rinsable …

  • GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Porous divinylbenzene homopolymer A PLOT column with polarity between Porapak-Q…

  • Agilent Technologies

    Reliable blood alcohol analysis Excellent confirmation column with DB-ALC2 for method using t-butanol as internal standard Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor…

  • Virtually equivalent to a (35%-Phenyl)-methylpolysiloxane Midpolarity Very low bleed characteristics Extended temperature limit of 340/360°C Excellent inertness for active compounds Ideal for conformational analyses Bonded, cross-linked and solvent rinsable …

  • Agilent Technologies

    Porous divinylbenzene homopolymer A PLOT column with polarity between Porapak-Q and Porapak-N Separates ethane, ethylene and ethyne (acetylene) Not recommended for quantification of polar compound Minimal conditioning time required — 1 hour Temperature limits:…

  • Agilent Technologies

    Beta-cyclodextrin in (35%-Phenyl)-methylpolysiloxane Chiral separations without chiral specific derivatization Phenyl-based polymer provides low bleed and does not interfere with nitrogen-specific detectors. Available in two concentrations of beta-cyclodextrin: 10% and 20% 20%…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Non-polar 100% Dimethylpolysiloxane Equivalent to HP-1 with tighter…

  • 100% Dimethylpolysiloxane Non-polar Superior performance of low molecular weight alcohols (less than C5) High temperature limit (325/350°C upper limit) Bonded and cross-linked; solvent rinsable This product is only available to U.S. Domestic Customers. Agilent…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Unique selectivity engineered for optimum resolution of volatiles analysis: U.S. EPA…

  • Agilent Technologies

    Equivalent to USP Phase G43 Thinner film reduces run time by 2.5 times and increases Minimum Detection Limit (MDL) by 2 times compared to standard film thickness used for this method Bonded and cross-linked Similar Phases: DB-624, PE-624, 007-624, 007-502, CP-624, ZB-624 …

  • Agilent Technologies

    100% Dimethylpolysiloxane Configured for the analysis of petroleum process products Tested to ensure the resolution of m-xylene from p-xylene and of cyclopentane from 2,3-dimethylbutane PONA, PIANO High resolution Bonded and cross-linked Solvent rinsable Similar…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Non-polar (5%-Phenyl)-methylpolysiloxane Equivalent to HP-5 with tighter…

  • Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…

  • Ideal column for melamine analysis Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed characteristics, ideal for GC/MS Excellent inertness for active compounds Improved signal-to-noise ratio for better sensitivity and mass…

Compare Tool

Select up to 3 products