Gas Chromatography Columns, Columns, Restek, Nucleic Acid
-
polar phase; Crossbond cyanopropylmethyl phenylmethyl polysiloxane The cyanopropyl-containing Rtx-225 phase is slightly less polar than bonded polyethylene glycol (PEG) phases, but it can be used for many of the same applications. Improvements to the Rtx-225 polymer have increased thermal…
-
Crossbond 100% dimethyl polysiloxane—optimized for hydrocarbon analysis Gasolines are complex mixtures of hundreds of compounds. Information about concentrations of the individual components is important for evaluating raw materials and for controlling refinery processes. ASTM D6730-01…
-
Restek Rt-Alumina BOND columns are highly selective for C1–C5 hydrocarbons and separate all saturated and unsaturated hydrocarbon isomers above ambient temperatures. The reactivity of the aluminum oxide stationary phase is minimized, by deactivation with inorganic salts like KCl or…
-
highly polar phase; biscyanopropyl cyanopropylphenyl polysiloxane Rtx-2330 is one of the most polar capillary column stationary phases. Cyano groups on both sides of the polymer backbone give the phase a strong dipole moment and high selectivity for cis/trans compounds or compounds with…
-
Micropacked GC Columns
RestekIncreased efficiency over traditional packed columns. Higher capacity than PLOT columns. Made from inert, flexible SilcoSmooth tubing. Wide range of packings available. Standard coils fit all instruments. No special instrument configurations required. Efficient, Inert, and…
-
Accurate quantification of toluene and benzene—including benzene in gasoline containing ethanol or butanol blends. Complete resolution of benzene from ethanol—no compromising coelutions. Enhanced formulation with improved support material and polymers—more robust and reproducible. Column sets…
-
Linearity for all reference compounds exceeds method requirements. Columns with retention gaps feature Alumaseal connectors to prevent leaks and extend column life. Low column bleed at high temperatures. For glycerin and glycerides analysis, according to ASTM D6584 and EN 14105 methods. …
-
midpolarity phase; Crossbond 35% diphenyl/65% dimethyl polysiloxane Active basic compounds that otherwise require derivatization, or an alternative analytical technique, can be analyzed on an Rtx-35 Amine column. The tubing surface is chemically altered to reduce tailing of basic compounds,…
-
Restek Rt-Alumina BOND columns are highly selective for C1–C5 hydrocarbons and separate all saturated and unsaturated hydrocarbon isomers above ambient temperatures. The reactivity of the aluminum oxide stationary phase is minimized, by deactivation with inorganic salts like KCl or…
-
2,3-di-O-methyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to…
-
permethylated beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to columns that have pure…
-
Restek Rt-Alumina BOND columns are highly selective for C1–C5 hydrocarbons and separate all saturated and unsaturated hydrocarbon isomers above ambient temperatures. The reactivity of the aluminum oxide stationary phase is minimized, by deactivation with inorganic salts like KCl or…
-
These application-specific columns for blood alcohol analysis baseline separate all critical compounds—including ethanol, methanol, acetone, tert-butanol, acetaldehyde, isopropanol, and n-propanol—in less than 2 minutes. Every Rtx-BAC Plus 1 and Rtx-BAC Plus 2 column is qualified with a…
-
D3606 Application Column Set
RestekConforms to the specifications established in the current ASTM method D3606 for the quantitation of benzene and toluene in spark ignition fuel containing ethanol. Complete resolution of benzene from ethanol—no compromising coelutions. Accurate quantification of benzene and toluene.…
-
Tested with a comprehensive test mix, to ensure high inertness Revolutionary deactivation process for superior inertness Analyze active samples accurately; ideal for chlorinated pesticide analysis (reduces endrin breakdown to less than 1%) Maximum temperature: 380°C
-
polar phase; Crossbond acid-deactivated Carbowax polyethylene glycol—for acidic compounds Stabilwax-DA bonded polyethylene glycol has an acidic functionality incorporated into the polymer structure. This permits analysis of acidic compounds without derivatization, significantly reduces…
-
polar phase; Crossbond polyethylene glycol The elution order of polyunsaturated FAMEs on FAMEWAX columns is comparable to that on other Carbowax columns, but baseline resolution is achieved in significantly less time. Application-specific columns for FAMEs, specially tested with a FAME…
-
proprietary Crossbond phase Rtx-VMS columns offer lower bleed, better selectivity, and overall faster analysis for separating volatile organic compounds, such as those listed in U.S. EPA Method 8260B. The Rtx-VMS stationary phase is a highly stable polymer that provides outstanding analysis of…
-
low-polarity phase; Crossbond diphenyl dimethyl polysiloxane The diphenyl dimethyl polysiloxane stationary phase is the most popular GC stationary phase and is used in a wide variety of applications. All residual catalysts and low molecular weight fragments are removed from the Rtx-5 polymer,…
-
proprietary Crossbond diphenyl/dimethyl polysiloxane phase An Rtx-502.2 column will enable you to quantify all compounds listed in U.S. EPA methods 502.2 or 524.2, whether you use a mass spectrometer or a PID in tandem with an ELCD. The diphenyl/dimethyl polysiloxane based Rtx-502.2 stationary…
-
These application-specific columns for blood alcohol analysis baseline separate all critical compounds—including ethanol, methanol, acetone, tert-butanol, acetaldehyde, isopropanol, and n-propanol—in less than 2 minutes. Every Rtx-BAC Plus 1 and Rtx-BAC Plus 2 column is qualified with a…
-
nonpolar phase; dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…
-
low-polarity phase; Crossbond 5% diphenyl/95% dimethyl polysiloxane Active basic compounds that otherwise require derivatization, or an alternative analytical technique, can be analyzed on an Rtx-5 Amine column. The tubing surface is chemically altered to reduce tailing of basic compounds,…
-
Proprietary cyclodextrin material added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to columns that have pure…
-
Useful for a wide range of applications Compatible with most common solvents Maximum temperature: 325°C
-
2,3-di-O-ethyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to…
-
low-polarity phase; Crossbond diphenyl dimethyl polysiloxane General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles. Column specifically tested for low-bleed performance. Temperature range:…
-
midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane Column specifically tested for low-bleed performance. Rtx-200 columns have accomplished many difficult separations not possible on any other bonded stationary phase. Many analysts consider these the best, most inert midpolarity…
-
midpolarity Crossbond phase Rtx-1701 is one of the more popular stationary phases used in capillary GC. The mix of cyano and phenyl functional groups increases the polarity and offers a different elution order relative to less polar Rtx-1 or Rtx-5 columns. An Rtx-1701 column is ideal for…
-
midpolarity Crossbond phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…
-
3x faster multiresidue pesticides analysis in foods. Factory-coupled, leak-free kit makes setting up LPGC as simple as a column change. Ideal for speeding up GC-MS and GC-MS/MS methods. Integrated transfer line reduces background and stabilization time.
-
2,3-di-O-propyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to…