Gas Chromatography Columns, Columns, PerkinElmer, Nucleic Acid Sample Preparation
-
Temperature range -60°C to 300/315°C.
-
Elite 1301 capillary column 30m x 0.25mm, 0.25µm
PerkinElmerTemperature range -20°C to 280°C Equivalent to USP G43 phase
-
Elite-1 capillary column, 15m x 0.25mm, 0.10µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Equivalent to USP G43 phase Temperature range -60°C to 330/350°C
-
Temperature range 40°C to 360°C Equivalent to USP G3
-
Elite-5 capillary column, 30m x 0.32mm, 0.25µm
PerkinElmerEquivalent to USP G27 and G36 phases Temperature range -60°C to 350°C
-
Elite-WAX capillary column 30m x 0.32mm, 0.50µm
PerkinElmerTemperature range 20oC to 250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
Capillary Column Support
PerkinElmerThe PerkinElmer capillary column support is designed to use with capillary split/split less injector and comes with all the instruments that are required to install the support.
-
Elite 624 capillary column 60m x 0.25mm, 1.40µm
PerkinElmerTemperature range -20°C to 240°C Equivalent to USP G43 phase
-
Polyimide Uncoated Deactivated Fused Silica Capillary Tubing comes in a standard length of 5 meters.
-
Empty Columns for all your Gas Chromatography equipment come in multiple sizes and are able to fit a variety of different systems.
-
-
Elite-200 capillary column 30m x 0.53mm, 3.00µm
PerkinElmerEquivalent to USP G6 phase. Temperature range -20°C to 260/280°C.
-
Elite 608 capillary column 75m x 0.32mm, 0.50µm
PerkinElmerThermally stable to 340°C Low column bleed - ideally suited for ECD and GC/MS analysis
-
-
Elite-200 capillary column 60m x 0.32mm, 1.00µm
PerkinElmerEquivalent to USP G6 phase. Temperature range -20°C to 290/310°C.
-
Elite-1 capillary column, 15m x 0.32mm, 0.25µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite 1301 capillary column 10m x 0.18mm, 0.40µm
PerkinElmerTemperature range -20°C to 280°C Equivalent to USP G43 phase
-
Refinery Gas Analyzer Calibration Blend without Syringe Adapter
-
Elite-1MS capillary column, 30m x 0.25mm, 0.25µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite-WAX ETR columns undergo a speical bonding process that binds the carbowax to the polar deactivated silica. The resuting low bleed WAX column exhibits extended lifetimes even when repeatedly heated to 260oC. The Elite-WAX ETR column can be used for a wide range of compounds such as FAMEs,…
-
Elite-1 capillary column, 15m x 0.32mm, 3.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite-1 capillary column 60m x 0.32mm, 1.50µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases. Temperature range -60°C to 310/330°C.
-
Temperature range -60oC to 200 oC
-
Elite-1 capillary column, 105m x 0.45mm, 2.55µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Temperature range -60°C to 320/340°C.
-
Elite-Siltek Guard, 5m x 0.32mm
PerkinElmerElite-Siltek Guard Columns lengthen the life of the capillary columns.
-
Elite-5MS capillary column 30m x 0.25mm, 0.25µm
PerkinElmerTemperature range -60oC to 350 oC Equivalent to USP G27, G36 phases
-
Our new line of Velocity fused silica columns yield exceptional performance for general Gas Chromatography (GC) applications without the cost associated with gas chromatography and mass spectrum analysis. PerkinElmer Velocity columns are excellent for standard daily test applications. They combine…
-
-
Elite-5MS capillary column 20m x 0.18mm, 0.18µm
PerkinElmerTemperature range -60oC to 350 oC Equivalent to USP G27, G36 phases
-
Temperature range -60°C to 300/315°C.