  • LIPODEX® cyclodextrin phases Capillary columns for GC enantiomer separation Features Base material: cyclic oligosaccharides consisting of six (α-cyclodextrin), seven (β-cyclodextrin) or eight (γ-cyclodextrin) glucose units bonded through α-1,4-linkages …

  • OPTIMA® 1 MS Accent Ultra-low bleed capillary columns for GC Features 100 % dimethylpolysiloxane · USP G1 / G2 / G38 Nonpolar phase with ultra-low bleeding, ideal for ion trap and quadrupole MS detectors Increased sensitivity due to an unmatched low background level …

  • OPTIMA® 1 Capillary columns for GC Features 100 % dimethylpolysiloxane · USP G1 / G2 / G38 Nonpolar phase Separation of components according to boiling points Thick film columns ≥ 3 µm film are expecially recommended for solvent analysis. Low bleed…

  • HYDRODEX cyclodextrin phases Capillary columns for GC enantiomer separation Features Base material: cyclic oligosaccharides consisting of seven (β-cyclodextrin) or eight (γ-cyclodextrin) glucose units bonded through α-1,4-linkages Regioselective derivatization…

  • OPTIMA® 1301 Capillary columns for GC Features 6 % cyanopropyl-phenyl – 94 % dimethylpolysiloxane USP G43 Medium polar phase Ideal for pesticide analyses For corresponding columns with higher film thickness see OPTIMA® 624 Similar phases: HP-1301, DB-1301,…

  • OPTIMA® 225 Capillary columns for GC Features 50 % cyanopropylmethyl – 50 % phenylmethylpolysiloxane · USP G7 / G19 Medium polar phase Recommended for fatty acid analyses Similar phases: DB-225, HP-225, OV-225, Rtx-225, CP-Sil 43, 007-225, BP225 Max.…

  • MACHEREY-NAGEL

    Untreated capillaries Recommended application: Capillary electrophoresis Preparation of capillary columns Capillary LC applications

  • Recommended application: Preparation of capillary columns As precolumns, whenever a larger contamination capacity is required Different deactivations are available: Methyl-Sil deactivated Phenyl-Sil deactivated CW deactivated

  • OPTIMA® 5 MS Capillary columns for GC Features 5 % diphenyl – 95 % dimethylpolysiloxane USP G27 / G36 Nonpolar phase with low bleeding Suited for GC/MS and ECD application and general analyses at trace level Perfect inertness for basic compounds Similar…

  • Untreated capillaries Recommended application: Capillary electrophoresis Preparation of capillary columns Capillary LC applications

  • OPTIMA® 17 MS Capillary columns for GC Features Silarylene phase with selectivity analogue to 50 % phenyl – 50 % methylpolysiloxane USP G3 Medium polar phase with very low bleeding Ideal for ion trap detectors, optimum reference column in combination with a 1 MS or 5…

  • OPTIMA® 624 LB Capillary columns for GC Features 6 % cyanopropyl-phenyl – 94 % dimethylpolysiloxane USP G43 Medium polar phase Low bleed columns for halogenated hydrocarbons, volatiles, aromatic compounds, solvents etc. Similar phases: HP-624, HP-VOC, DB-624,…

  • Capillary columns for GC Features Polyethylene glycol 20 000 Da · USP G16 Polar phase Recommended for solvent analysis and alcohols, suitable for aqueous solutions Similar phases: OPTIMA® WAX, DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, Rtx-Wax, CP-Wax 52 CB, Stabilwax,…

  • OPTIMA® 1701 Capillary columns for GC Features 14 % cyanopropyl-phenyl – 86 % dimethylpolysiloxane · USP G46 Medium polar phase Special selectivity due to high cyanopropyl content Reference column for structure identification, e.g., in combination with…

  • OPTIMA® WAX Capillary columns for GC Features Polyethylene glycol 20 000 Da USP G16 Polar phase Recommended for solvent analysis and alcohols, suitable for aqueous solutions Similar phases: DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, Rtx-Wax, CP-Wax 52 CB, Stabilwax,…

  • OPTIMA® BioDiesel Capillary columns for the analysis of BioDiesel (DIN EN 14214 / ASTM D 6751) OPTIMA® BioDiesel F for analysis of FAMEs in accordance with DIN EN 14103:2011 The analysis of biodiesel requires separation of typical FAMEs between myristic acid (C14) and nervonic…

  • OPTIMA® 5 Amine GC capillary columns for amine separation Features Especially deactivated for the analysis of polyfunctional amines such as ethanol­amines, amino-functionalized diols and similar compounds, which are important base materials in industrial chemistry, and show…

  • OPTIMA® 5 Capillary columns for GC Features 5 % phenyl – 95 % methylpolysiloxane · USP G27, G36 Nonpolar standard phase with large range of application Low bleed columns with equal selectivity see OPTIMA® 5 MS, ultra low bleed columns see OPTIMA® 5 MS…

  • GC capillary columns for determination of diethylene glycol Features Polyethylene glycol 20 000 (diethylene glycol tested) · USP G16 Recommended application: determination of diethylene glycol, e.g., for the quality control of wine Max. temperature for isothermal operation…

  • OPTIMA® 210 Capillary columns for GC Features Trifluoropropyl-methylpolysiloxane (50 % trifluoropropyl) USP G6 Medium polar phase Recommended for environmental analyses, especially for o-, m- and p-substituted aromatic hydrocarbons Similar phases: OV-210, DB-210,…

  • OPTIMA® 240 Capillary columns for GC Features 33 % cyanopropyl-methyl – 67 % dimethylpolysiloxane Medium polar phase Recommended for FAMEs, dioxins No similar phases Max. temperature for isothermal operation 260 °C Max. temperature for short isotherms in a…

  • OPTIMA® δ-3 Capillary columns for GC Features Polysiloxane phase with autoselectivity USP G49 Medium polar without CN groups Analytes determine the polarity of the phase Autoselectivity resulting in a polarity range from approximately the nonpolar OPTIMA® 5 to…

  • OPTIMA® 17-TG GC capillary columns for triglyceride analyses Features Phenyl-methyl-polysiloxane (50 % phenyl) · USP G3 Offers separation according to degree of unsaturation Short capillary columns (max. 25 m and 0.32 mm ID) with low-bleeding stationary phases …

  • PERMABOND® P-100 GC capillary column for analysis of petrochemical products Features Extra long column with nonpolar dimethylpoly­siloxane phase USP G1 / G2 / G38 high resolution and sufficient capacity for analysis of complex mixtures of hydrocarbons Max. temperature…

  • OPTIMA® FFAPplus Capillary columns for GC Features Polyethylene glycol 2-nitroterephthalate USP G35 Polar phase with optimized crosslinking for lower column bleeding Recommended application: FAMEs, free carboxylic acids Similar phases: DB-FFAP, HP-FFAP, CP-Wax 58…

  • OPTIMA® 1-TG GC capillary columns for triglyceride analyses Features 100 % dimethylpolysiloxane · USP G1 / G2 / G38 offers separation according to carbon number Short capillary columns (max. 25 m and 0.32 mm ID) with low-bleeding stationary phases thermally stable…

  • OPTIMA® 17 Capillary columns for GC Features Phenylmethylpolysiloxane (50 % phenyl) · USP G3 Medium polar phase Recommended application: steroids, pesticides, drug analyses Low bleed columns with equal selectivity see OPTIMA® 17 MS Similar phases: OV-17,…

  • MACHEREY-NAGEL

    The retention gap technique in combination with on-column injection allows concentration of a large sample volume in the capillary column. Choice of the retention gap depends on the solvent used: the flooded zone after injection should be between 20–30 cm/µL Me-Sil retention…

  • OPTIMA® XLB Capillary columns for GC Features Silarylene phase with optimized silarylene content for lowest column bleed Lowest column bleed, nonpolar phase Ideal for ion trap and quadrupole MS detectors perfect inertness for basic compounds solvent rinsing for removal…

  • OPTIMA® 1301 MS Capillary columns for GC Features Silarylene phase with selectivity analog to 6 % cyanopropyl-phenyl – 94 % dimethylpolysiloxane USP G43 Mid-polar phase with very low bleed 100 % ion trap and quadrupol MS compatibility Recommended application:…

  • OPTIMA® 5 MS Accent Capillary columns for GC Features Silarylene phase with polarity similar to a 5 % diphenyl – 95 % dimethylpolysiloxane phase · USP G27, G36 Lowest column bleed, nonpolar phase, ideal for ion trap and quadrupole MS detectors Solvent rinsing for…

  • OPTIMA® δ-6 Capillary columns for GC Features Polysiloxane phase with autoselectivity Medium polar without CN groups Analytes determine the polarity of the phase Autoselectivity resulting in a polarity range from approximately OPTIMA® 17 to OPTIMA® 210 …

Compare Tool