Agilent Technologies

Efficient LC Solutions that deliver the fast, reproducible results you need


  • Agilent Technologies

    Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass…

  • Agilent Technologies

    (35%-Phenyl)-methylpolysiloxane Midpolarity - slightly more polar than HP-35 Low bleed Inert to active solutes Ideal for confirmational analyses Bonded and cross-linked Solvent rinsable Equivalent to USP Phase G42 Similar Phases: Rtx-35, SPB-35, AT-35,…

  • Agilent Technologies

    Nitroterephthalic acid modified polyethylene glycol High polarity Designed for the analysis of volatile fatty acids and phenols Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 Temperature limits: 40° to 250°C NOTE: Agilent does…

  • Agilent Technologies

    (50%-Phenyl)-methylpolysiloxane Midpolarity Extended upper temperature limit of 365°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Improved resolution for triglycerides Ideal for…

  • quick-ship

    Agilent Technologies

    (14%-Cyanopropyl-phenyl)-methylpolysiloxane Low/midpolarity Bonded and cross-linked Solvent rinsable Exact replacement for HP-1701 Similar Phases: DB-1701: SPB-1701, CP-Sil 19 CB, Rtx-1701, BP-10, OV-1701, 007-1701, ZB-170 Agilent Technologies products are intended for…

  • Agilent Technologies

    (50%-Phenyl)-methylpolysiloxane Midpolarity slightly more polar than HP-50+ Suitable for confirmational analyses Bonded and cross-linked Solvent rinsable Temperature limits are 40° to 260/280°C or 40° to 280/300°C Equivalent to USP Phase G3 HP-50+, Rtx-50,…

  • Agilent Technologies

    100% Dimethylpolysiloxane Identical selectivity to DB-1 Non-polar Very low bleed characteristics, ideal for GC/MS Improved acid performance compared to standard 100% Dimethylpolysiloxane columns Improved signal-to-noise ratio for better sensitivity and mass spectral integrity …

  • Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limits: -60° to 325°C isothermally, -60° to 350°C programmed. -60° to 300°C isothermally, -60° to 320°C programmed for 0.53 mm columns -60° to 260°/280°C…

  • Agilent Technologies

    Agilent J&W GS-CarbonPLOT uses a high stability, carbon-layer stationary phase to deliver unique selectivity for inorganic and organic gases. The column features an extended temperature limit to 360 °C. The retention stability of GS-CarbonPLOT is not affected by water, and the column is…

  • Agilent Technologies

    (50%-Trifluoropropyl)-methylpolysiloxane High polarity Excellent for U.S. EPA Methods 8140 and 609 Bonded and cross-linked Solvent rinsable Exact replacement of HP-210 Close equivalent to USP Phase G6 Similar Phases: SP-2401 Agilent Technologies products…

  • Agilent Technologies

    100% Dimethylpolysiloxane Identical selectivity to HP-1 Non-polar Low bleed characteristics General purpose column Improved signal-to-noise ratio for better sensitivity and mass spectral integrity Bonded and cross-linked Solvent rinsable Temperature range:…

  • Agilent Technologies

    Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes Column-to-column repeatability Bonded and cross-linked Solvent rinsable …

  • Agilent Technologies

    Nitroterephthalic acid modified polyethylene glycol High polarity Temperature range from 40 to 250°C Designed for the analysis of volatile fatty acids and phenols Replaces OV-351 Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 …

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-5 (2713R99, T86, T94 and V89) (5%-Phenyl)-methylpolysiloxane Non-polar …

  • Agilent Technologies

    Base deactivated polyethylene glycol Specifically designed for amine analysis Excellent peak shape for primary amines Replaces HP-Basicwax Similar Phases: Stabilwax-DB, Carbowax Amine Because the CAM is not bonded or cross-linked, we do not recommend solvent rinsing. …

  • Agilent Technologies

    100% Dimethylpolysiloxane Non-polar Specially processed for extended temperature limit of 400°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Bonded and cross-linked Solvent rinsable …

  • Agilent Technologies

    Virtually equivalent to (50%-Cyanopropylphenyl)-methylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Low bleed Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G7 Similar Phases:…

  • Agilent Technologies

    Virtually equivalent to (50%-Phenyl)-methylpolysiloxane 320°/340°C upper temperature limit Very low bleed midpolarity, suitable for GC/MS Exhibits inertness to active compounds Enhanced mass spectral integrity Bonded and cross-linked Solvent rinsable Best…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Nitroterephthalic acid modified polyethylene glycol High polarity Temperature…

  • Agilent Technologies

    50%-Cyanopropyl)-methylpolysiloxane High polarity Designed for separation of fatty acid methyl esters (FAMEs) Excellent resolution for cis- and trans-isomers Bonded and cross-linked Solvent rinsable Replaces HP-23 Close equivalent to USP Phase G5 Similar…

  • quick-ship

    Agilent Technologies

    Virtually equivalent to a (35%-Phenyl)-methylpolysiloxane Midpolarity Very low bleed characteristics Extended temperature limit of 340/360°C Exhibits inertness to active compounds Suitable for confirmational analysis Bonded and cross-linked Solvent rinsable …

  • Agilent Technologies

    (50%-Cyanopropylphenyl)-dimethylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Bonded and cross-linked Solvent rinsable Exact replacement of HP-225 Close equivalent to USP Phase G7 Similar Phases:…

  • Agilent Technologies

    DX-1: 90% Dimethylpolysiloxane - 10% Polyethylene Glycol DX-4: 15% Dimethylpolysiloxane - 85% Polyethylene Glycol Because DX series GC columns are not bonded and cross-linked, we do not recommend solvent rinsing. Agilent Technologies products are intended for sale/shipment within…

  • Agilent Technologies

    100% Dimethylpolysiloxane Industry standard general purpose column Non-polar Wide range of applications Superior performance of low molecular weight alcohols High temperature limit Bonded and cross-linked Solvent rinsable Wide range of column dimensions …

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Non-polar Excellent general purpose column …

  • Agilent Technologies

    Bonded PLOT column technology Suitable for light hydrocarbons and sulfur gas Retention stability not affected by water Separates CO and CO2 on a single column Ideal PLOT column for CG/MS - no particles Temperature limits: -80° to 260°/300°C …

  • Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar General purpose column Wide range of applications Low bleed High temperature limit: -60° to 325/350°C* Bonded and cross-linked Solvent rinsable Wide range of column dimensions available Equivalent to USP…

  • Agilent Technologies

    Polyethylene glycol (PEG) Extended Temperature Range (etr) High polarity Excellent column-to-column repeatability Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G16 Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52 CB, SUPEROX II, CB-WAX,…

  • Agilent Technologies

    Meets ASTM 6584 and EN14105 Standards 100% Dimethylpolysiloxane Non-polar Specially processed for extended temperature limit of 400°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Bonded and…

  • Agilent Technologies

    (35%-Phenyl)-methylpolysiloxane Midpolarity - slightly less polar than DB-35 Inert to active solutes Ideal for confirmational analyses Bonded and cross-linked Solvent rinsable Equivalent to USP Phase G42 Similar Phases: Rtx-35, SPB-35, AT-35, Sup-Herb, DB-35,…

  • Agilent Technologies

    Specifically designed for the analysis of chlorinated pesticides and PCBs U.S. EPA Methods: 608, 508, 8080 Excellent inertness and recoveries without pesticide breakdown Bonded and cross-linked Solvent rinsable Exact replacement of HP-608 Similar Phases: SPB-608,…

  • Agilent Technologies

    Meets EN14331 Standards (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass spectral integrity Bonded and cross-linked…