Gas Chromatography Columns, Columns, NEW! Life Science
-
Elite-17ms columns are for confirmation analysis and have excellent inertness for active compounds
-
5% diphenyl, 95% dimethyl polysiloxane Optimized for PBDE analysis by EPA Method 1614. Short column option resolves BDE-209 3 times faster, with less thermal breakdown. Unique deactivation gives higher BDE-209 response than competitor columns, for greater analytical sensitivity. …
-
SLB®-5ms Capillary GC Column
MilliporeSigmaApplication: The 5% phenyl equivalent phase provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. The low bleed characteristics, inertness, and durable nature make it the column of choice for environmental analytes (such as semivolatiles,…
-
DB-5ms
Agilent TechnologiesPhenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass…
-
Elite-35ms capillary column 25m x 0.20mm, 0.33µm
PerkinElmerEquivalent to USP G42 phase Temperature range 40°C to 340°C/360°C
-
Duraguard Columns
Agilent TechnologiesColumns with “built in” guard columns, no press-fit connectors Minimize front-end contamination and increase column lifetime Aid in focusing sample onto the front of the column for better peak shape Minimize MSD contamination originating from the column (when used in…
-
DB-35
Agilent Technologies(35%-Phenyl)-methylpolysiloxane Midpolarity - slightly more polar than HP-35 Low bleed Inert to active solutes Ideal for confirmational analyses Bonded and cross-linked Solvent rinsable Equivalent to USP Phase G42 Similar Phases: Rtx-35, SPB-35, AT-35,…
-
polar phase; Crossbond acid-deactivated Carbowax polyethylene glycol—for acidic compounds Stabilwax-DA bonded polyethylene glycol has an acidic functionality incorporated into the polymer structure. This permits analysis of acidic compounds without derivatization, significantly reduces…
-
Restek GC Packing Material
RestekHayeSep® porous polymers are macroporous, spherical, ultrapure resins for performing unique separations in gas chromatography. Columns packed with HayeSep® polymers produce lower bleed and more reproducible characteristics than those packed with any competing polymeric product, and they require…
-
Molecular Sieve Columns
RestekMolecular sieve packed columns easily separate permanent gases at above-ambient temperatures. Restek’s R&D chemists have developed a process for preparing molecular sieve packings, which results in excellent batch-to-batch reproducibility. In addition, our molecular sieves are…
-
Untreated Capillaries
MACHEREY-NAGELUntreated capillaries Recommended application: Capillary electrophoresis Preparation of capillary columns Capillary LC applications
-
DB-FFAP
Agilent TechnologiesNitroterephthalic acid modified polyethylene glycol High polarity Designed for the analysis of volatile fatty acids and phenols Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 Temperature limits: 40° to 250°C NOTE: Agilent does…
-
Deactivated Fused Silica Tubing
Agilent TechnologiesDeactivated tubing can be used as retention gaps, guard columns, or transfer lines. Our standard deactivation process is a phenyl methyl deactivation — the preferred choice for most applications due to its inertness and robustness. Agilent Technologies products are intended for…
-
-
midpolarity Crossbond phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…
-
low-polarity phase; Crossbond diphenyl dimethyl polysiloxane General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles. Column specifically tested for low-bleed performance. Temperature range:…
-
PERMABOND® CW 20 M Capillary Columns
MACHEREY-NAGELCapillary columns for GC Features Polyethylene glycol 20 000 Da · USP G16 Polar phase Recommended for solvent analysis and alcohols, suitable for aqueous solutions Similar phases: OPTIMA® WAX, DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, Rtx-Wax, CP-Wax 52 CB, Stabilwax,…
-
The Rtx-Volatile Amine column was designed specifically for analyzing volatile amines in difficult matrices, such as water. The unique base deactivation creates an exceptionally inert surface for these sensitive compounds, resulting in highly symmetrical peaks, which allow low detection limits. The…
-
polar phase; Crossbond polyethylene glycol Restek’s polar-deactivated surface tightly binds the Carbowax polymer and increases thermal stability, relative to competitive columns. Because of the increased stability produced by the bonding process, Stabilwax columns exhibit long column…
-
Restek's R&D chemists have optimized the deactivation technology applied to our MXT-Alumina BOND/MAPD column for improved analysis of trace concentrations of polar hydrocarbons like acetylene, methyl acetylene, and propadiene in hydrocarbon streams containing higher levels of C1-C5…
-
Elite 624 capillary column 60m x 0.25mm, 1.40µm
PerkinElmerTemperature range -20°C to 240°C Equivalent to USP G43 phase
-
Elite-5MS capillary column 60m x 0.32mm, 0.25µm
PerkinElmerTemperature range -60oC to 350 oC Equivalent to USP G27, G36 phases
-
SPB®-35 Capillary GC Column
MilliporeSigmamaterial fused silica Quality Level 100 Agency meets requirements for USP G42 parameter 0-300 °C temperature (isothermal or programmed) Beta value 250 df 0.25 μm technique(s) gas chromatography…
-
2,3-di-O-ethyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to…
-
-
Temperature range -60°C to 300/315°C.
-
OPTIMA® 225 Capillary Columns
MACHEREY-NAGELOPTIMA® 225 Capillary columns for GC Features 50 % cyanopropylmethyl – 50 % phenylmethylpolysiloxane · USP G7 / G19 Medium polar phase Recommended for fatty acid analyses Similar phases: DB-225, HP-225, OV-225, Rtx-225, CP-Sil 43, 007-225, BP225 Max.…
-
Column GC Cap High Efficiency HP-1ms 20m, 0.18mm, 0.18um
Agilent Technologies100% Dimethylpolysiloxane Non-polar Low bleed characteristics Improved signal-to-noise ratio for better sensitivity and mass spectral integrity Bonded and cross-linked and solvent rinsable Agilent Technologies products are intended for sale/shipment within the US only. International…
-
Absorption chromatography column for rapid preparative separations as described by W.C. Still, M. Kahn and A. Mitra of Columbia University in JOURNAL OF ORGANIC CHEMISTRY 43, 2923 [1978], and covered in U.S. Patent Number 4,293,422 dated October 6, 1981. Moderate resolution can be obtained with…
-
Elite-5MS capillary column 20m x 0.18mm, 0.18µm
PerkinElmerTemperature range -60oC to 350 oC Equivalent to USP G27, G36 phases
-
ShinCarbon ST Columns
RestekAnalyze oxygen, nitrogen, methane, carbon monoxide, and carbon dioxide with one column at room temperature. ShinCarbon ST material, a high surface area carbon molecular sieve (~1,500 m 2 /g), is the ideal medium for separating gases and highly volatile compounds by gas solid chromatography (GSC).…
-
DB-17ht
Agilent Technologies(50%-Phenyl)-methylpolysiloxane Midpolarity Extended upper temperature limit of 365°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Improved resolution for triglycerides Ideal for…