Reduce cell culture contamination by lowering extractables in filtration devices

 

Are the extractables from Nalgene Rapid-Flow receiver bottles lower when compared to similar devices?

Yes, under specific conditions. In three different extractable analyses, the Thermo Scientific™ Nalgene™ Rapid-Flow™ receiver bottles were lower in extractable content compared to three equivalent devices from different manufacturers.

What are extractables?

Extractables are possible contaminants from plastic products that most commonly originate from the synthesis of the polymer, resin components, manufacturing process, or use of additives, which are necessary for the performance of the product. Extractables can be inorganic, may contain metals, and/or organic compounds.

How can extractables impact my sample?

Extractables may be released from a plastic device under certain conditions and, if present, may represent a risk of passively migrating (or “leaching”) into the sample leading to unintended consequences. If a filtration device has a high level of extractables there is a risk of contaminating the filtrate. It is important to be mindful of these compounds and consider how they could impact an experiment or accumulate in downstream processes.

What methods were used to test for extractables?

Methods developed were based on United States Pharmacopeia (USP) extraction conditions and testing requirements for plastic components. Triplicates from the same lot of polystyrene receiver bottles from three manufacturers were tested with 100 mL of three extraction solutions (water, 50:50 ethanol:water, and 2% nitric acid in water). The polystyrene receiver bottles with respective extraction solutions were incubated for 21 days at 50°C before analysis.

Three analyses were run on each of the extracts. Total organic carbon (TOC) was measured from the water extracts using a Hach™ QBD1200 Laboratory TOC Analyzer. The λmax absorbance was measured from the 50:50 ethanol:water extracts using the Thermo Scientific™ Evolution 220 UV-Vis spectrophotometer. Thermo Scientific™ iCAP™ RQ inductively coupled mass spectrometry (ICP-MS) was used for elemental analysis of 2% nitric acid in water.

What are the results and conclusions?

TOC results show that the Nalgene Rapid-Flow filtration units were 50–70% lower in detected TOC levels when compared to the equivalent receiver bottles from three other suppliers (Figure 1). In direct comparison, the Nalgene Rapid-Flow receiver bottle had 996 parts per billion (ppb) verses 2074 ppb for supplier M (Figure 2). TOC often results from the catalysts used during the synthesis of the polymer, the polymer itself, or from the slip agents used during molding.


Absorbance data ( λmax) at 245 nm show that  that the concentration of extractables was 30–40% less in the Nalgene Rapid-Flow receiver bottles when compared to the equivalent receiver bottles from three other suppliers (Figure 1). In direct comparison, the Nalgene Rapid-Flow receiver bottle absorbance results were 0.153 verses 0.217 for supplier M (Figure 3). Increased absorbance is directly proportional to an increased concentration of extractables when comparing similar λmax values.


The metals analysis results show that there were no detectable metals in the Nalgene Rapid-Flow receiver bottles whereas silicon (28Si), titanium (47Ti), and tantalum (181Ta) were detected among the equivalent receiver bottles from supplier M (Figure 4).

When evaluating extractables, less is more. The lower the extractables, the less chance of those compounds leaching into your filtered sample. The Nalgene Rapid-Flow receiver bottles had less extractables present compared to all other equivalent filtration devices. Thermo Fisher Scientific sources only virgin resins from the highest quality suppliers to ensure consistency and quality as well as optimizes products and processes to avoid the use of various additives and slip agents whenever possible. Furthermore, to provide additional transparency, the product change notification system alerts customers of any changes, including from suppliers, made to a product—adding another level of confidence in trusting Thermo Fisher Scientific products.

Click HERE to order your Nalgene Rapid-Flow filtration units.

Latest Articles

Mar04

How to Choose Your Ideal Lab Refrigerator

Discover your ideal lab refrigerator! From temperature control to safety features, our latest blog guides you through the journey of choosing the perfect laboratory refrigeration. Explore cold storage features and frills at their finest.

Read More >

Jan05

Thomas Scientific Leaders Partner with The Salvation Army Sending Warm Wishes to Those in Need

1500 Salvation Army older adults and youth to receive cold weather essentials

Read More >

Nov06

How an independent lab overcame the challenges of a post-pandemic world.

While many are familiar with the general upheavals in the healthcare industry as a result of the COVID-19 pandemic, one of the oft-forgotten stars of the drama are diagnostic laboratories. These labs played a critical part right from the very beginning...

Read More >

Write A Comment