• PRODUCT AVAILABILITY: Did you know you can view a product's availability right on the product page? Simply enter the quantity you want to purchase and the current availability will appear below the item.

Advantech

Sonic Sifter Components

Not yet rated

Sonic Sifter Components

Additional Views

Column Lock - This metal (aluminum and stainless steel) fixture’s arms locks on to the Base/Fines Collector Holder, holding the Stack Assembly together for it to be placed into the sifter’s Test Chamber. Once inside the Test Chamber, the locking arms are released and tension holds the Stack Assembly in place during testing. The arms are then reengaged with the Base/Fines Collector Holder so the Stack Assembly can be removed from the sifter safely after testing.

Diaphragm - This latex disk encloses/covers the particles within the top cone so they do not escape. During testing, the column of air caused by the sonic wave’s effect on the membrane assists in the trying of particles. Diaphragms inevitably wear out over time and have expiration dates.

Top Cone - Clear acrylic funnel-like ring provides a loading area for of the test sample. It also assists in directing the sonic waves down the Column to best try the particles.

Acrylic Spacer (6 for full Stack) – This ?" high clear acrylic ring are used as extenders when either the test material needs more space to move or to complete the Stack when there are not enough sieves being used (full stack required for the Column to lock).

Fines Collector – This latex pouch at the bottom of the Stack collects the finest particles. Fines Collectors inevitably wear out over time and have expiration dates.

Base/Fines Collector Holder – This sturdy aluminum base holds the Fines Collector and is an anchor in which the Column Lock connects to during transfer.

Complete Stack Assembly – includes: 1 Column Lock, 1 Diaphragm, 1 Top Cone, 6 Acrylic Spacers (sieves not included), 1 Fines Collector, and 1 Fines Collector Holder.

  • Column Lock* – This metal (aluminum and stainless steel) fixture’s arms locks on to the Base/Fines Collector Holder, holding the Stack Assembly together for it to be placed into the sifter’s Test Chamber. Once inside the Test Chamber, the locking arms are released and tension holds the Stack Assembly in place during testing. The arms are then reengaged with the Base/Fines Collector Holder so the Stack Assembly can be removed from the sifter safely after testing.
  • Diaphragm – This latex disk encloses/covers the particles within the top cone so they do not escape. During testing, the column of air caused by the sonic wave’s effect on the membrane assists in the trying of particles. Diaphragms inevitably wear out over time and have expiration dates.
  • Top Cone – Clear acrylic funnel-like ring provides a loading area for of the test sample. It also assists in directing the sonic waves down the Column to best try the particles.
  • Acrylic Spacer (6 for full Stack) – This ?" high clear acrylic ring are used as extenders when either the test material needs more space to move or to complete the Stack when there are not enough sieves being used (full stack required for the Column to lock).
  • Fines Collector – This latex pouch at the bottom of the Stack collects the finest particles. Fines Collectors inevitably wear out over time and have expiration dates.
  • Base/Fines Collector Holder – This sturdy aluminum base holds the Fines Collector and is an anchor in which the Column Lock connects to during transfer.
This content is hosted by a third party (youtube.com). To view external content you must agree to cookies.
This content is hosted by a third party (youtube.com). To view external content you must agree to cookies.

Compatible with Advantech L3P Sonic Sifter and VariSifter Sonic Separator

Please Enter Your Order Info

Filter by:

  • Clear Filters
Product Detail
Thomas No.
20A00R704
Mfr. No.
L3-N1
Description
Column Lock – This metal (aluminum and stainless steel) fixture’s arms locks on to the Base/Fines Collector Holder, holding the Stack Assembly together for it to be placed into the sifter’s Test Chamber. Once inside the Test Chamber, the locking arms are released and tension holds the Stack Assembly in place during testing. The arms are then reengaged with the Base/Fines Collector Holder so the Stack Assembly can be removed from the sifter safely after testing.
list price/quantitytotal
$0.00
Thomas No.
20A00R705
Mfr. No.
L3-N2
Description
Diaphragm – This latex disk encloses/covers the particles within the top cone so they do not escape. During testing, the column of air caused by the sonic wave’s effect on the membrane assists in the trying of particles. Diaphragms inevitably wear out over time and have expiration dates.
list price/quantitytotal
$0.00
Thomas No.
20A00R706
Mfr. No.
L3-N3
Description
Top Cone – Clear acrylic funnel-like ring provides a loading area for of the test sample. It also assists in directing the sonic waves down the Column to best try the particles.
list price/quantitytotal
$0.00
Thomas No.
20A00R707
Mfr. No.
L3-N4
Description
Acrylic Spacer – This ?" high clear acrylic ring are used as extenders when either the test material needs more space to move or to complete the Stack when there are not enough sieves being used (full stack required for the Column to lock).
list price/quantitytotal
$0.00
Thomas No.
20A00R708
Mfr. No.
L3-N5
Description
Fines Collector – This latex pouch hangs at the bottom of the Stack and collects the finest particles. Fines Collectors inevitably wear out over time and have expiration dates.
list price/quantitytotal
$0.00
Thomas No.
20A00R709
Mfr. No.
L3-N6
Description
Base/Fines Collector Holder – This sturdy aluminum base holds the Fines Collector and is an anchor in which the Column Lock connects to during transfer.
list price/quantitytotal
$0.00
Thomas No.
20A00R710
Mfr. No.
L3-N7
Description
Complete Stack Assembly – includes: 1 Column Lock, 1 Diaphragm, 1 Top Cone, 6 Acrylic Spacers (sieves not included), 1 Fines Collector, and 1 Fines Collector Holder.
list price/quantitytotal
$0.00
$0.00 (0 Items)

Write A Review