• PRODUCT AVAILABILITY: Did you know you can view a product's availability right on the product page? Simply enter the quantity you want to purchase and the current availability will appear below the item.

PCR Strip Tubes

Additional Views

  • Packaged in resealable bags
  • All ILP PCR products are non-sterile and certified to be free of detectable RNase, DNases, DNA, and pyrogen contamination.
  • Durable bands between the wells keep these strips ridged, easy to handle, and durable.  Sections of tubes will not inadvertently break apart but are easily cut with scissors into smaller sections or individual tubes.

 

PC0108-D-N

Minimize evaporation especially when used with small sample volumes, in thermal cyclers with heated lids, or older units with our standard profile, 0.1ml well volume, 8-PCR tube and domed cap strips.  Precision molded using only ultra-clear, virgin, medical grade polypropylene for clarity and sample visualization.  When used together they create a secure and proper fit for precise thermal transfer with minimal evaporation.

ILP domed cap strips are designed to assist condensate to re-enter the reaction mixture and in heat transfer.  Caps have longer cap flanges that produce a tight fit and reduce sample evaporation.  Tubes and caps are regularly quality tested for evaporation rates and must exhibit less than 3% sample loss.

Individual tube volumes:

  • Overall Volume: 180 µl
  • Working Volume: <100 µl

Cap strips have large end tabs for easy removal and are labeled for orientation.  They are easy to apply and remove without breaking.

Recommended for low to medium throughput applications, these tubes are designed to fit all low profile 0.1mL block thermal cyclers.  Their thin and consistent wall thickness optimizes heat transfer to maximize yield.

PC0108-TF-N

Achieve even and precise thermal transfer to maximize your yield with our low profile, 0.1ml well volume, 8-PCR tube and flat cap strips.  Precision molded using only ultra-clear, virgin, medical grade polypropylene for clarity and sample visualization.  When used together they create a secure and proper fit for precise thermal transfer with minimal evaporation.

ILP flat cap strips offer a frosted finish that is perfect for labeling or writing.  Caps have longer cap flanges that produce a tight fit and reduce sample evaporation.  Tubes and caps are regularly quality tested for evaporation rates and must exhibit less than 3% sample loss.

Individual tube volumes

  • Overall Volume: 180 µl
  • Working Volume: <100 µl

Cap strips have large end tabs for easy removal and are labeled for orientation.  They are easy to apply and remove without breaking.

Recommended for low to medium throughput applications, these tubes are designed to fit all low profile 0.1mL block thermal cyclers.  Their thin and consistent wall thickness optimizes heat transfer to maximize yield.

PC108Q-TF-N

Get the most from your qPCR with our low profile, 0.1ml well volume, 8-PCR tube and optically clear flat cap strips.  Precision molded using only ultra-clear, virgin, medical grade polypropylene for clarity and sample visualization.  When used together they create a secure and proper fit for precise thermal transfer with minimal evaporation.

Optically clear flat cap strips are ideal for fluorescence detection, luminescence, and imaging techniques including qPCR.  The upper surfaces are extremely clear and offer greatly improved light transmittance over standard flat caps. Light signals pass through uninhibited for consistent and reliable qPCR performance.

Caps have longer cap flanges that produce a tight fit and reduce sample evaporation.  Tubes and caps are regularly quality tested for evaporation rates and must exhibit less than 3% sample loss.

Individual tube volumes

  • Overall Volume: 180 µl
  • Working Volume: <100 µl

Cap strips have large end tabs for easy removal and are labeled for orientation.  They are easy to apply and remove without breaking.

Recommended for low to medium throughput applications, these tubes are designed to fit all low profile 0.1mL block thermal cyclers.  Their thin and consistent wall thickness optimizes heat transfer to maximize yield.

PC108Q-TF-W

Get the best signal with our low profile, 0.1ml white well volume, 8-PCR tube and optically clear flat cap strips.  Precision molded using only ultra-clear, virgin, medical grade polypropylene for clarity and sample visualization.  When used together they create a secure and proper fit for precise thermal transfer with minimal evaporation.

Optically clear flat cap strips are ideal for fluorescence detection, luminescence, and imaging techniques including qPCR.  The upper surfaces are extremely clear and offer greatly improved light transmittance over standard flat caps. Light signals pass through uninhibited for consistent and reliable qPCR performance.

Caps have longer cap flanges that produce a tight fit and reduce sample evaporation.  Tubes and caps are regularly quality tested for evaporation rates and must exhibit less than 3% sample loss.

Individual tube volumes

  • Overall Volume: 180 µl
  • Working Volume: <100 µl

Cap strips have large end tabs for easy removal and are labeled for orientation.  They are easy to apply and remove without breaking.

Recommended for low to medium throughput applications, these tubes are designed to fit all low profile 0.1mL block thermal cyclers.  Their thin and consistent wall thickness optimizes heat transfer to maximize yield.

PC0208-D-N

Minimize evaporation especially when used with small sample volumes, in thermal cyclers with heated lids, or older units with our standard profile, 0.2ml well volume, 8-PCR tube and domed cap strips.  Precision molded using only ultra-clear, virgin, medical grade polypropylene for clarity and sample visualization.  When used together they create a secure and proper fit for precise thermal transfer with minimal evaporation.

ILP domed cap strips are designed to assist condensate to re-enter the reaction mixture and in heat transfer.  Caps have longer cap flanges that produce a tight fit and reduce sample evaporation.  Tubes and caps are regularly quality tested for evaporation rates and must exhibit less than 3% sample loss.

Individual tube volumes:

  • Overall Volume: 300 µl
  • Working Volume: <200 µl

Cap strips have large end tabs for easy removal and are labeled for orientation.  They are easy to apply and remove without breaking.

Recommended for low to medium throughput applications, these tubes are designed to fit all standard 0.2mL block thermal cyclers.  Their thin and consistent wall thickness optimizes heat transfer to maximize yield.

 

PC0208-TF-N

Achieve even and precise thermal transfer to maximize your yield with our standard profile, 0.2ml well volume, 8-PCR tube and flat cap strips.  Precision molded using only ultra-clear, virgin, medical grade polypropylene for clarity and sample visualization.  When used together they create a secure and proper fit for precise thermal transfer with minimal evaporation.

ILP flat cap strips offer a frosted finish that is perfect for labeling or writing.  Caps have longer cap flanges that produce a tight fit and reduce sample evaporation.  Tubes and caps are regularly quality tested for evaporation rates and must exhibit less than 3% sample loss.

Individual tube volumes

  • Overall Volume: 300 µl
  • Working Volume: <200 µl

Cap strips have large end tabs for easy removal and are labeled for orientation.  They are easy to apply and remove without breaking.

Recommended for low to medium throughput applications, these tubes are designed to fit all standard 0.2mL block thermal cyclers.  Their thin and consistent wall thickness optimizes heat transfer to maximize yield.

 

PC208Q-TF-N

Get the most from your qPCR with our standard profile, 0.2ml well volume, 8-PCR tube and optically clear flat cap strips.  Precision molded using only ultra-clear, virgin, medical grade polypropylene for clarity and sample visualization.  When used together they create a secure and proper fit for precise thermal transfer with minimal evaporation.

Optically clear flat cap strips are ideal for fluorescence detection, luminescence, and imaging techniques including qPCR.  The upper surfaces are extremely clear and offer greatly improved light transmittance over standard flat caps. Light signals pass through uninhibited for consistent and reliable qPCR performance.

Caps have longer cap flanges that produce a tight fit and reduce sample evaporation.  Tubes and caps are regularly quality tested for evaporation rates and must exhibit less than 3% sample loss.

Individual tube volumes

  • Overall Volume: 300 µl
  • Working Volume: <200 µl

Cap strips have large end tabs for easy removal and are labeled for orientation.  They are easy to apply and remove without breaking.

Recommended for low to medium throughput applications, these tubes are designed to fit all standard 0.2mL block thermal cyclers.  Their thin and consistent wall thickness optimizes heat transfer to maximize yield.

PC0208-D-ATT

Tube strips with attached domed caps minimize evaporation especially when used with small sample volumes, in thermal cyclers with heated lids, or older units.  Achieve even and precise thermal transfer while minimizing evaporation with our 0.2ml, 8- tube and attached dome cap strips.  Precision molded as a single part creates a secure and proper fit for precise thermal transfer with minimal evaporation.

ILP domed cap strips are designed to assist condensate to re-enter the reaction mixture and in heat transfer.  Caps have longer cap flanges that produce a tight fit and reduce sample evaporation.  Tubes with attached caps are regularly quality tested for evaporation rates and must exhibit less than 3% sample loss.

Individual tube volumes

  • Overall Volume: 300 µl
  • Working Volume: <200 µl

Each tube is joined to a cap making cross contamination with the wrong cap impossible.  Their thin and consistent wall thickness optimizes heat transfer to maximize yield.

Recommended for low to medium throughput applications, these tubes are designed to fit all standard 0.2mL block thermal cyclers.  Caps are angularly attached to allow full loading of standard thermal blocks and racks.

PC0208-TF-ATT

Tube strips with attached flat caps make cross contamination and missing caps a thing of the past.  Achieve even and precise thermal transfer to maximize your yield with our standard profile, 0.2ml well volume, 8-PCR tube with attached flat cap strips.  Precision molded using only ultra-clear, virgin, medical grade polypropylene for clarity and sample visualization.

These ILP attached tube and cap for PCR offer the same labeling surface.  Molding as a single part ensures a uniform fit for precise thermal transfer with minimal evaporation.  Tubes with attached caps are regularly quality tested for evaporation rates and must exhibit less than 3% sample loss.

Individual tube volumes

  • Overall Volume: 300 µl
  • Working Volume: <200 µl

Each tube is joined to a cap making cross contamination with the wrong cap impossible.  Their thin and consistent wall thickness optimizes heat transfer to maximize yield.

Recommended for low to medium throughput applications, these tubes are designed to fit all standard 0.2mL block thermal cyclers.  Caps are angularly attached to allow full loading of standard thermal blocks and racks.

PC208Q-TF-ATT

Molded as a single part, our standard profile, 0.2ml 8-tube with attached optically clear flat cap strips make cross contamination and missing caps a thing of the past.  Achieve even and precise thermal transfer while minimizing evaporation in your qPCR.  Precision molded using only ultra-clear, virgin, medical grade polypropylene for clarity and sample visualization.

Optically clear flat cap strips are ideal for fluorescence detection, luminescence, and imaging techniques including qPCR.  The upper surfaces are extremely clear and offer greatly improved light transmittance over standard flat caps. Light signals pass through uninhibited for consistent and reliable qPCR performance.

Caps have longer cap flanges that produce a tight fit and reduce sample evaporation.  Tubes with attached caps are regularly quality tested for evaporation rates and must exhibit less than 3% sample loss.

Individual tube volumes

  • Overall Volume: 300 µl
  • Working Volume: <200 µl

Each tube is joined to a cap making cross contamination with the wrong cap impossible.  Their thin and consistent wall thickness optimizes heat transfer to maximize yield.

Recommended for low to medium throughput applications, these tubes are designed to fit all standard 0.2mL block thermal cyclers.  Caps are angularly attached to allow full loading of standard thermal blocks and racks.

Please Enter Your Order Info

Filter by:

  • Clear Filters
Product Detail
Thomas No.
21A00F777
Mfr. No.
PC0108-D-N
Description
0.1mL 8-strip Tube & Domed Cap, Nat
list price/quantitytotal
$0.00
Thomas No.
21A00F778
Mfr. No.
PC0108-TF-N
Description
0.1mL 8-strip Tube & Frosted Flat Cap, Nat
list price/quantitytotal
$0.00
Thomas No.
21A00F779
Mfr. No.
PC108Q-TF-N
Description
0.1mL 8-strip Tube & Optical Flat Cap, qPCR, Nat
list price/quantitytotal
$0.00
Thomas No.
21A00F780
Mfr. No.
PC108Q-TF-W
Description
0.1mL 8-strip Tube & Optical Flat Cap, qPCR, White
list price/quantitytotal
$0.00
Thomas No.
21A00F781
Mfr. No.
PC0208-D-N
Description
0.2mL 8-strip Tube & Domed Cap, Nat
list price/quantitytotal
$0.00
Thomas No.
21A00F782
Mfr. No.
PC0208-TF-N
Description
0.2mL 8-strip Tube & Frosted Flat Cap, Nat
list price/quantitytotal
$0.00
Thomas No.
21A00F783
Mfr. No.
PC208Q-TF-N
Description
0.2mL 8-strip Tube & Optical Flat Cap, qPCR, Nat
list price/quantitytotal
$0.00
Thomas No.
21A00F784
Mfr. No.
PC0208-D-ATT
Description
0.2mL 8-strip Tube w/ att Domed Caps, Nat
list price/quantitytotal
$0.00
Thomas No.
21A00F785
Mfr. No.
PC0208-TF-ATT
Description
0.2mL 8-strip Tube w/ att Frosted Flat Caps, angled, Nat
list price/quantitytotal
$0.00
Thomas No.
21A00F786
Mfr. No.
PC208Q-TF-ATT
Description
0.2mL 8-strip Tube w/ att Optical Flat Caps, qPCR, Nat
list price/quantitytotal
$0.00
$0.00 (0 Items)

Write A Review