• PRODUCT AVAILABILITY: Did you know you can view a product's availability right on the product page? Simply enter the quantity you want to purchase and the current availability will appear below the item.

  • Product C900E42 is restricted and can only be purchased by customers with a web profile linked to a Thomas Business Account - Click here to login or create your web profile. If you do not have a Thomas Business Account, please Contact Us and someone will respond with details on how to apply for a business account with us.

SPEX CertiPrep

spex® ICP-MS Contract Required Detection Limit Standard 1

Not yet rated

Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2. The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability. US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentration levels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. A standard must be run at two times the Contract Required Detection Limits (CRDL), or at two times the Instrument Detection Limits (IDL), whichever is greater. This standardization is performed at the start and the end of each sample analysis or at least twice in each eight hour shift. All elements to be analyzed must be run except Al, Ba, Ca, Fe, K, Mg, and Na. Our CRDL-1 and CL-CRDL-1standards contain all of the required elements on the TAL, in their appropriate concentration ratios. CRDL-1 should be diluted by a factor of 1,000 prior to use in the "two times CRDL" run for ICP-AES analysis. For analysis by atomic absorption, CRDL-1 should be diluted by a factor of 2,000 prior to use in the "one time CRDL" run. CL-CRDL-1 should be diluted by a factor of 1,000 prior to use in the "two times CL-CRDL" run for ICP analysis. For analysis by atomic absorption, CL-CRDL-1 should be diluted by a factor of 2,000 prior to use in the "one time CL-CRDL" run.

Please Enter Your Order Info

Filter by:

  • Clear Filters
Product Detail
Thomas No.
C900E42
Mfr. No.
CL-CRDL-1
Description
ICP/ICPMS CONTRACT REQUIRED DE
Grade
ICP-MS
Organic / Inorganic
Inorganic
Packaging Size
100 mL
list price/quantitytotal
$0.00
$0.00 (0 Items)
Product C900E42 is restricted and can only be purchased by customers with a web profile linked to a Thomas Business Account - Click here to login or create your web profile. If you do not have a Thomas Business Account, please Contact Us and someone will respond with details on how to apply for a business account with us.

Write A Review