Solid Phase Extraction (SPE) Columns
-
CHROMAFIL® filtration cartridges
MACHEREY-NAGELFeatures Filtration cartridges for sample clarification under vacuum (e.g., using the CHROMABOND® vacuum manifold or SPE automation systems like Gilson Aspec™, Rapidtrace) or by gravity Cartridge sizes 3 mL and 6 mL Different membranes: PET (polyester); RC (regenerated…
-
CHROMABOND® Flash RS SiOH Cartridges
MACHEREY-NAGELIdeal for Flash separations from 10 mg up to 300 g Features For convenient operation and reliable upscaling the complete program of ready-to-use Flash cartridges for the Isco Companion® and other Teledyne Isco CombiFlash® systems, or as stand-alone version for all…
-
CHROMABOND® PA
MACHEREY-NAGELCHROMABOND® SPE products Features More than 50 different sationary phases available e.g., silica gel based: unmodified, C8, C18, NH2, CN; Polyermic material: HR-X, HLB, PA; mixed-mode, special combinations, aluminum oxide, kieselguhr (XTR) etc. NP, RP, ion exchanger and for special…
-
CHROMABOND® Flash RS C18 ec Cartridges
MACHEREY-NAGELIdeal for Flash separations from 10 mg up to 300 g Features For convenient operation and reliable upscaling the complete program of ready-to-use Flash cartridges for the Isco Companion® and other Teledyne Isco CombiFlash® systems, or as stand-alone version for all…
-
Affinimip SPE is a selective solid phase extraction based upon molecularly printed polymers (MIP). It combines the advantages of Immune-affinity columns in terms of selectivity and a classic solid phase extraction (SPE) in terms of robustness and costs. This selectivity and robustness combines to…
-
CHROMABOND® C18 ec
MACHEREY-NAGELFeatures More than 50 different sationary phases available e.g., silica gel based: unmodified, C8, C18, NH2, CN; Polyermic material: HR-X, HLB, PA; mixed-mode, special combinations, aluminum oxide, kieselguhr (XTR) etc. NP, RP, ion exchanger and for special applications Different…
-
CHROMABOND® C6H5
MACHEREY-NAGELPhenyl-modified silica phase for SPE Features Base material silica, pore size 60 Å, particle size 45 µm, specific surface 500 m2/g, pH stability 2–8 Phenyl phase, carbon content 8 %, polarity similar to C8 In addition to hydrophobic interactions more selective…
-
-
SPE columns, CHROMABOND WAX
MACHEREY-NAGELPS/DVB copolymer with secondary and tertiary ammonium modification for mixed-mode SPE with weak anion exchange and reversed-phase properties (WAX). Exchange capacity ≥ 0.8 meq/g, pKa 6 + 9. High-purity material with ideal flow properties and highest reproducibility. Allows highest…
-
CHROMABOND® Flash Columns and Connecting Kits
MACHEREY-NAGELConnecting kits for CHROMABOND® Flash columns CHROMABOND® Flash Starter Kit consists of: 1/8" PTFE tubing, ID 1.5 mm, length 3 m; 5 x 1/4"-28 PP nuts; 5 x 1/8" ETFE ferrules; 5 x 1/4"-28 nylon unions; 2 x 1/4"-28 PP luer locks female; 1 x 1/4"-28 PP luer…
-
Sep-Pak Accell Plus QMA Carbonate Plus Light cartridges contain a silica-based, hydrophilic, strong anion-exchanger with a large pore size (300Å) and a carbonate counter-ion. These cartridges are used for extraction of anionic analytes in aqueous and non-aqueous solutions when the chloride…
-
CHROMABOND® Flash RS SPHERE SiOH Cartridges
MACHEREY-NAGELIdeal for Flash separations from 10 mg up to 300 g Features For convenient operation and reliable upscaling the complete program of ready-to-use Flash cartridges for the Isco Companion® and other Teledyne Isco CombiFlash® systems, or as stand-alone version for all…
-
Populate base plate with only the wells needed 50 µL elution volume for minimal sample dilution and reduced evaporation time Optimized well geometry for 5 and 10 mg sorbent masses Use with vacuum or positive pressure The internal diameter, frit design, and sorbent material of…
-
CHROMAFIX® Dry (Na2SO4)
MACHEREY-NAGELSpecial phase for drying organic samples Features Anhydrous high-purity sodium sulfate which forms Glauber’s salt with traces of water – For removal of larger quantities of water several cartridges can be combined in series. Recommended application: removal of traces of…
-
AFFINIMIP® SPE PAHs Selective Cartridges
AffinisepAffinimip SPE is a selective solid phase extraction based upon molecularly printed polymers (MIP). It combines the advantages of Immune-affinity columns in terms of selectivity and a classic solid phase extraction (SPE) in terms of robustness and costs. This selectivity and robustness combines to…
-
CHROMABOND® HLB
MACHEREY-NAGELHydrophilic-lipophilic balanced N-vinylpyrrolidone-divinylbenzene resin for SPE Features Hydrophilic-lipophilic balanced N-vinylpyrrolidone-divinylbenzene copolymer pH stability 1–14 Spherical particles 30 μm or 60 μm (standard) Pore size 65 Å Specific surface…
-
Supel(TM) QuE Verde Tube
MilliporeSigmaDispersive SPE (dSPE), often referred to as the "QuEChERS" method (Quick, Easy, Cheap, Effective, Rugged, and Safe), is modern sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. Using the QuEChERS method,…
-
-
SampliQ Silica C18 Endcapped SPE Cartridges
Agilent TechnologiesReversed Phase (Non-Polar) 25% carbon loading Silica-based particles reduce pressure drop and increase flow reproducibility Average particle size of 45 µm and pore diameter of 60 Angstrom to reduce pressure drop and increase flow reproducibility Agilent’s…
-
-
CHROMABOND® HR-P
MACHEREY-NAGELPolystyrene-divinylbenzene adsorbent resin for SPE Features Highly porous polystyrene-divinylbenzene copolymer specific surface 1200 m2/g, particle size 50–100 μm very high binding capacity, up to 30 % of adsorbent weight (for comparison: silica adsorbents about 3 %) …
-
HybridSPE®-PLus 96-Well Plate
MilliporeSigmaHybridSPE-PLus is the next generation of HybridSPE-Phospholipid technology. The first of its kind, HybridSPE-Phospholipid technology was first introduced in 2008. It fuses the simple, standardized methodology of traditional protein precipitation with the specificity of solid phase extraction (SPE)…
-
Empty SPE Tube (no frits)
MilliporeSigmaSolid phase extraction apparatus uses glass vials or tubes for sample collection and concentration. Some sorbents require large desorption volume than small SPE cartridges in such case SPE tubes were used. Synonyms: SPE Reservoir Application: Empty SPE Tube (no frits) was coupled with…
-
CHROMABOND® Reservoir Columns
MACHEREY-NAGELReservoir columns for application of medium-size samples.
-
Affinimip SPE is a selective solid phase extraction based upon molecularly printed polymers (MIP). It combines the advantages of Immune-affinity columns in terms of selectivity and a classic solid phase extraction (SPE) in terms of robustness and costs. This selectivity and robustness combines to…
-
CHROMABOND® HR-XAW
MACHEREY-NAGELWeakly basic secondary and tertiary ammonium polymeric anion exchanger for SPE Features Base material spherical PS/DVB copolymer, pore size 55–65 Å, particle sizes 45 µm or 85 µm (standard) very large specific surface 850 m2/g, pore volume 1.2–1.4 cm3/g, pH…
-
CHROMABOND® HILIC
MACHEREY-NAGELAmmonium – sulfonic acid modified silica phase for SPE Features Base material silica, pore size 60 Å, particle size 45 µm, specific surface 500 m2/g zwitterionic polar phase with ammonium – sulfonic acid modification, carbon content 7 %, pH stability 2-8 Polar…
-
Female Luer Cap polypropylene
MilliporeSigmaUse to close Luer port. Polypropylene. Synonyms: Luer Plugs & Caps
-
CHROMABOND® Empty Columns
MACHEREY-NAGELFor individual packing of SPE columns with CHROMABOND® adsorbents.
-
Discovery® DSC-18 SPE Tube
MilliporeSigmaRetention Mechanism: Reversed-phaseSample Matrix Compatibility: Aqueous solutions (biological fluids, water) •Polymerically bonded, octadecyl (18 %C), endcapped •Higher 18 %C loading for increased binding capacities and higher recoveries •The least selective phase: retains most organic analytes…
-
Supel(TM) QuE Verde Tube
MilliporeSigmaDispersive SPE (dSPE), often referred to as the "QuEChERS" method (Quick, Easy, Cheap, Effective, Rugged, and Safe), is modern sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. Using the QuEChERS method,…
-
Supel(TM) QuE Non-Buffered Tube
MilliporeSigmaDispersive SPE (dSPE), often referred to as the "QuEChERS" method (Quick, Easy, Cheap, Effective, Rugged, and Safe), is modern sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. Using the QuEChERS method,…