Water Distillation Apparatus

Compare Tool

Select up to 3 products

Water Distillation Apparatus
1 - 32 of 44
Sort
View
Show

Aries Filterworks

  • Water / Crude Oil Distillation Apparatus

    DWK Life Sciences (Kimble)

    Conforms to ASTM D 4006 Apparatus is used for the distillation of water in crude oil. Apparatus includes 1,000 mL RB flask, 24/40 joints, Dean-Stark distillation receiver, dry trap and Liebig condenser Heating mantle must be purchased seperately

  • Cyanide Distillation Apparatus

    DWK Life Sciences (Kimble)

    …analysis of various industrial waste waters, saline and reagent grade water. Cyanide is released as HCN acid from cyanide complexes by means of reflux-distillation and absorbed in a scrubber containing a sodium hydroxide solution. Apparatus includes a reactor head, cold-finger condenser,…

  • General Distillation Apparatus

    DWK Life Sciences (Kimble)

    KIMAX® apparatus used in general purpose distillation and phenol distillation. Flask has a flat bottom and a distillation head with a 19/38 joint Supplied with a Standard Taper stopper Condenser is Graham-style, having a 200 mm jacket with a 19/38 joint at the top only For…

  • Distillation Apparatus, Cyanide

    Ace Glass

    Apparatus for converting simple and most complex cyanides into HCN and for from most interferences before measuring by titration or colorimetric analysis examination of industrial wastes and other water. Method is described in Standard the Examination of Water and Wastewater. Fourteenth Edition,…

  • Distillation Apparatus, Cyanide

    Ace Glass

    Cyanide distillation apparatus used in testing for soluble and insoluble cyanides in water. Apparatus basically conforms to ASTM D-2036 except for modifications involving Ace-Threds and larger joints. Also available with threaded adapter to connect still head to trap. PTFE ferrules are supplied in…

  • Distillation Apparatus, Ammonia

    Ace Glass

    Generally used for the determination of ammonia in water. Joints are standard taper 24/40.

  • Distillation Apparatus, Cyanide

    Ace Glass

    Used in testing for soluble and insoluble cyanides in water. Basically conforms to ASTM D 2036 (excluding modifications). Flask is 1L with 24/40 joint and #7 Ace-Thred permitting variable depth positioning of fill tube which has a float valve for added protection against boil back. Jacketed still…

  • Distillation Adapter, Claisen

    DWK Life Sciences (Kimble)

    Provides dual entry into a variety of flasks BEVEL-SEAL adapters allow temperature measurements at either top outer opening. Useful for reflux with addition- type reactions. Adapter consists of two female standard taper joint fittings at the top and one male standard taper joint at the bottom.…

  • Kjeldahl, Distillation Unit, 6-Unit

    Labconco

    …infinite-control knobs with variable input from 20-100% capacity and distillation manifold equipped with six seamless stainless steel tubes, cooling water temperature gauge and remote control flow valve. Inlet and outlet water connections are 3/4" NPT. Supply line must be 1/2" ID minimum. Includes…

  • PYREX® Cyanide Distilling Apparatus

    Corning

    This PYREX® cyanide distilling apparatus is used in testing for soluble and insoluble cyanides in water. Cyanide as hydrocyanic acid (HCN) is released from cyanide complexes by means of a reflux-distillation and absorbed in a scrubber containing a sodium hydroxide solution. Tygon® tubing…

  • KIMAX® Distilling Apparatus

    DWK Life Sciences (Kimble)

    Bent angle of 105°, with Standard Taper joints on inlet and outlet ends and inner drip-tip which bypasses vacuum take-off tubulation Has drip-tip at exit end Side-arm accepts 5/16” i.d. flexible tubing Made from Kimax® Brand KG-33 borosilicate glass, which features a low coefficient of…

  • PYREX® Distilling Apparatus

    Corning

    A general purpose batch distillation assembly with the facility for addition via the Standard Taper PYREX® stopped neck Ideally suited for the batch production of high purity distilled water The flask bottom is flat with a slide delivery tube, terminating in a Standard Taper joint …

  • General Purpose Distilling Apparatus

    Wilmad LabGlass

    These borosilicate glass apparatus are used in general purpose and phenol distillation. They are useful for batch production of high purity water. Complete unit consists of a flask with a flat bottom and distillation head having Standard Taper 19/38 joint, Standard Taper Stopper, and Graham style…

  • Kjeldahl, Distillation Apparatus, 2-Unit, 115V

    Labconco

    …with variable input from 20-100% capacity; and distillation manifold equipped with two seamless stainless steel tubes and cooling water temperature gauge and remote control flow valve. Inlet and outlet water connections are 3/8" NPT. Connection to water source with tubing and fittings is required…

  • Ammonia Nitrogen Apparatus

    DWK Life Sciences (Kimble)

    Apparatus is for determining the proteinaceous nitrogen content in water. It is also useful for preparing small quantities of distilled water. Apparatus can be used for phenol, selenium and fluoride determinations. It has 24/40 Standard Taper joint and a #2 hose connection. Unit measures 595 mm H x…

  • Distillation Apparatus, Steam, Nielsen-Kryger, Improved Version

    Ace Glass

    For exhaustive distillation of pesticides and industrial chemicals from water, sediments and tissue, and the simultaneous extraction of the distillate by a small volume of organic solvent. The addition of a bulb condenser in place of the straight tube condenser results in more efficient condensing…

  • Combination Hooded Kjeldahl Apparatus

    Labconco

    Hooded Combination Kjeldahl units enclose the distillation and digestion apparatus so that process heat may be contained and vented from the laboratory. The hood surrounding the apparatus includes three collars: one for remotely-located exhaust blower connection, one for acid fume exhaust manifold…

  • Soxhlet/Dean Stark Extraction Apparatus

    DWK Life Sciences (Kimble)

    This apparatus combines two analytical techniques, Soxhlet extraction and Dean-Stark azeotropic distillation, into a single process for the removal of water, chlorinated dibenzo-p-dioxins (CCDs) and chlorinated dibenzofurans (CDFs) from wet particulate samples. Determination of water and…

  • Distilling Column, Water Jacketed

    Chemglass

    Jacketed distilling column has indentations on the inner tube to support packing material. The jacket allows the column to be used as a condenser. Column has a top outer and lower inner standard taper joint. All sizes have an I.D. of approximately 10mm.

  • Distilling Traps

    Corning

    …• For ASTM Standard D 322; ANSI method Z11.29; API standard 524; and Federal Test Method Standard No. 791, method 3001.5 • For determination of water in petroleum or bituminous materials in Barrett test B-2 • Meets ASTM Standard D 95 • With Standard Taper 24/40 outer member at top and Standard…

  • Distilling Tube Connector

    Corning

    Standard Taper 10/30 thermometer opening, distilling, three-way, Standard Taper joints Sidearm is at an angle approximately 75° from the lower part of the vertical tube The joint on the sidearm is at an angle approximately 105° from the sidearm The sidearm and lower tube are…

  • PYREX® Distilling Tube Adapters

    Corning

    60° angle Three Standard Taper 24/40 joints Approximate length 206 mm This tube is also a replacement for organic chemistry kits. Type I, Class A borosilicate conforming to federal specification DD-G-54 lb and ASTM E 438. Also meets the US Pharmacopoeia specs for Type I borosilicate glass.

  • Distilling Receiver, Dean-Stark, Modified

    Chemglass

    …azeotropic distillations using solvents that are heavier than water. The solvent vapor travels through tube “A” to a condenser inserted in the top standard taper outer joint. Vapors are condensed and collected in the reservoir section. The layers separate and the heavier than water

  • PYREX® Distilling Flasks

    Corning

    Suitable for microchemical applications Side-arm on all sizes is approximately 77 mm below the top of the neck at an angle of 75° Adaptable for use with thermometer calibrated for 76 mm immersion 50 mL flask takes rubber stopper No. 1; 250 mL flasks, stopper No. 3; 500 mL flask, stopper No. 4;…

  • Distilling Receiver, Moisture Test, Dean-Stark

    Chemglass

    Dean-Stark receiver used for determining the water content of various materials. Can be used with ASTM Method D-95 along with similar ASTM methods.

  • Distilling Receiver, Moisture Test, Dean-Stark

    Chemglass

    Modified Dean-Stark receiver designed for solvents that are either lighter or heavier than water. The lower three-way PTFE stopcock allows for the withdraw or return of the distillate during the distillation process. With a 10/30 outer joint on the top of the vapor tube for a 3” immersion…

  • Distilling Head, Short Path, Improved

    Chemglass

    …the condenser being a combination of a cold coil and Liebig. Water flows into hose connection “A” through the coil and exits the outer jacket through hose connection “B”. Head is excellent for use when distilling medium to high boiling point solvents. Top outer joint is a…

  • Distilling Receiver, Moisture Test, Barrett

    Chemglass

    Barrett style distilling receiver used to determine the water content in petroleum or bituminous material. Receiver is made according to ASTM specifications, with the addition of the top outer standard taper joint and lower stopcock. Available with glass or PTFE stopcocks.

  • PYREX® 250mL Solvent Still Head Distilling Apparatus, Standard Taper Joints

    Corning

    This 250mL capacity PYREX® solvent still head is used for maintaining oxygen free solvents. Head has sufficient storage space to allow solvent removal by syringe or drainage through 2mm T-bore PTFE (Polytetrafluorethylene) stopcock. It has a 24/40 Standard Taper outer joint at top, 24/40 Standard…

  • KIMAX Stark-Dean Traps

    DWK Life Sciences (Kimble)

    … Specialized for determination of water in emulsified asphalts With Standard Taper24/40 joints and reflux overflow return tube Graduated 0 to 1 mL in 1/10 mL and 3 to 20 mL in 1/5 mL divisions For use in the determination of water in petroleum products and bituminous materials…

  • PYREX Stark-Dean

    Corning

    PYREX®10 mL , Stark- Dean For use in the determination of water in petroleum products and bituminous materials Graduated in 1/10 mL divisions from 0 to 1 mL ; in 1/5 mL divisions from 1 to 10 mL With Standard Taper 24/40 joints; meets ASTM Standard E 123

  • RapidStill I

    Labconco

    …plug. Includes fill valve for filling the boiling flask, rear cooling water connections through the back of the housing, adjustable height shelf to support the receiving flask, water bottle for introducing distilled water to the boiling flask via the fill valve, and one large "U" clamp…

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.