  • …in the bath senses any over-temperature fault condition and cuts off power to the bath until an operator resets the over-temperature limit circuit. All power from the bath is removed if RTD is disconnected. A liquid-level control prevents bath heating until a safe liquid level is attained. The bath

  • …specifications Constant temperature bath has an available automatic timing feature for viscosity determinations. Microprocessor PID circuitry assures precise temperature control within ASTM specified tolerances throughout the operating range of the bath. Simple push-button controls and dual…

  • viscosity determinations between 10°C and 30°C Built-in thermoelectric cooling provides “rock-solid” temperature control at ambient and below Meets ASTM D 445 precision specifications from 10°C to 100°C The Cannon CT-600 has many of the engineering and control features of the CT-500 bath, but…

  • Viscosity Bath Media

    MilliporeSigma

    Silicone Fluid 50 cSt at 25 °C for use 90 to 120 °C

  • viscosity of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 and ISO 3104 requirements Specifications conform to ASTM D 446 and ISO 3105 Precision: ±0.2% Individually boxed. Minimum sample volume: 7 mL. Require liquid bath depth…

  • BS/U/M Miniature U-Tube

    Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of…

  • …measuring viscosity of highly viscous materials such as asphalt cement at 60°C (140°F) Meets ASTM D 2171 Applicable to materials with viscosity range of 42 to 5,800,000 poises With graduated capillary to extend viscosity range of viscometer Minimum sample size: 3 mL. Requires bath depth of 180…

  • Calibrated viscometers For measuring kinematic viscosity of opaque Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.3%. Minimum sample volume: 7 mL. Requires liquid bath depth of 280 mm (11"). Includes certificate…

  • Calibrated Viscometers For measurement of kinematic viscosity of small samples of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 requirements Precision: ±0.2% Specifications conform with ASTM Standard D 446. Minimum sample…

  • An extremely stable, medium viscosity, silicone oil. Available in two temperature ranges: Low Temp. maximum 180 degree C; or High Temp. maximum 230 degree C. Neither oil shows discoloration after 40 hours at maximum temperature.

  • The digital heating bath is characterized by the following features: Cylindrical bath shape High-grade recyclable materials The heating elements are situated underneath the bath vessel Either low viscosity oil or water can be used as the heat transfer fluid Useful volume of 4 liters …

  • Sturdy two-drawer unit fits beneath the Constant Temperature Bath Provides elevated viewing of the bath and ample room for storage of viscometers and other accessories. Overall dimensions: 457 mm wide x 457 mm deep x 165 mm high. Weight: 24 lbs.

  • CBC Bath Coolers

    Cannon Instrument

    …controlled by the bath’s built-in circuitry. At ambient temperatures of 25°C or below, the CBC can cool any liquid bath down to as low as 10°C if the bath can be set to control at that temperature. The CBC can also be used to improve the temperature stability of viscosity baths when operating…

  • Ford Viscosity Cups

    BYK-Gardner

    …Built-in cooling circulating coil The cup is inserted into center tube of bath. Water temperature is maintained by connecting the coolant coil to your present circulating constant temperature equipment. The bath is made of aluminum with copper coolant coils. Only water in coolant coil…

  • Bath Oil, 6-Gallon Container

    Cannon Instrument

    Contains an oxidation inhibitor which reduces tendency to darken at higher temperatures For use below 135°C (275°F) For higher temperature requirements, see Thomas number 6428R25.

  • …Flow Unit (9655U15) Stainless steel Threaded for attachment to 9655S15 series Disruptor Horns Permits continuous processing of low viscosity materials at rates up to 38 liters per hour Provided with water jacket, input, output and overflow connections. Sealed Chambers…

  • …of insulating glass and are suitable for low temperatures down to -60°C. This makes them ideal for the use with the fully-automatic LAUDA PVS viscosity measuring system. The two-chamber principle in the measuring area ensures a constant level, irrespective of the loading and the temperature. The…

  • Removable Viscometer Holders

    Cannon Instrument

    All Cannon viscometer holders are designed to fit holes 51 mm (2 in.) in diameter. Rubber holders are made of neoprene rubber.  Plastic holders hold the viscometer firmly with a spring clip.  Metal holders are constructed of chrome-plated machined brass.  A handle permits…

  • …ensures a uniform temperature throughout the bath. The bath chamber is a cylindrical clear glass vessel 300 mm in diameter x 300 mm high. A second thermistor in the bath senses any over-temperature fault condition and removes all power from the bath until an operator resets the over-temperature…

  • Viscosity Bath Media

    MilliporeSigma

    Silicone Fluid 20 cSt at 25 °C for use 60 to 110 °C

  • Viscosity Bath Media

    MilliporeSigma

    Silicone Fluid 100 cSt at 25 °C for use 120 to 150 °C

  • Bath Fluid

    Thomas®

    Silicone bath fluid Superior heat transfer medium in melting point baths, etc. High thermal and chemical stability This clear, colorless, oily liquid has a nominal viscosity of 50 centistokes at 25°C, with a viscosity/ temperature coefficient of 0.59. The boiling point is over 360°C with a…

  • … Factory calibrated Minimal consumable expense 3 mL solvent Expanded viscosity range Single instrument covers ISO VG 10 to 700 10 to 700 mm 2 /s (cSt) Portable and Rugged Smaller than other capillary instruments Solid bath (no liquid) Fully self-contained  

  • …100°C and 0.03°C above 100°C, providing the temperature sensitivity required by ASTM D 445 for kinematic viscosity measurements. Two electric heating elements inside the bath rapidly heat the medium to any desired temperature within the range. A cooling coil, when connected to tap water…

  • …switch on the front panel allows direct setting of eight temperatures commonly used for low-temperature viscosity measurement: -30, -25, -20, -15, -10, -5, 0, and 10°C. After setting, the bath will equilibrate to within a fraction of a degree of the desired temperature. A fine-tuinig dial them…

  • Viscosity Bath Media

    MilliporeSigma

    White Oil for use 40 to 80 °C

  • Viscosity Bath Media

    MilliporeSigma

    White Oil for use 80 to 120 °C

  • Viscosity Bath Media

    MilliporeSigma

    Silicone Fluid 10 cSt at 25 °C for use 40 to 100 °C

  • …(TC) at 20°C, this heavy walled borosilicate glass viscosity flask has a top with reinforced lip and is used in determining Saybolt viscosity of petroleum and bituminous materials. This receiving flask can be used in Saybolt viscometer baths. Conforms to ASTM D 88 specifications. Each flask is…

  • … Circulating Baths Heating Circulating Baths Stainless Steel Open Bath Systems Polycarbonate Open Bath Systems Specialty Products Viscosity Bath Calibration Bath 75L Refrigerated Circulating Bath Coliform Bath General Purpose Water Baths Chillers & Coolers…

  • …selectable operation Continuous on-screen monitoring of bath temperature through built-in platinum resistance thermometer Meets ASTM D 445 requirements for measurements of kinematic viscosity at low temperatures Bath and calibration temperatures can be entered digitally on keypad.…

  • Solid Rubber Micro Stopper

    Cannon Instrument

    Tapered from 6 mm top diameter to 2 mm bottom diameter, these solid rubber micro stoppers measure 20 mm long. Micro stoppers are for use with Cannon-Fenske Qpaque Viscometer and Cannon Cold-Cranking Simulator.