Viscometer Standard
-
-
Viscometer
A&D WeighingViscometer with revolutionary range & technology - Redefining standard viscosity determination. Advanced vibrating tuning fork technology works on a wide range of Newtonian Fluids. Provide fast accurate results and it is simple to use. Advanced benefits in difficult sample with low & high…
-
Saybolt Viscometer Bath
Koehler…and dual digital displays permit easy setting and monitoring of bath temperature. Two-place calibration offset is provided. Accommodates four viscometers and four 60 mL receiving flasks. Sliding draft shields and a chemical-resistant alignment plate facilitate handling of the flasks and glare-free…
-
BS/IP/SL Suspended Level Viscometer
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105 Precision: ±0.2% Minimum sample volume: 11 mL. Requires liquid bath depth of 250 mm (10”).…
-
Semi-Micro, Cannon CUSMC Series Viscometer
Cannon InstrumentCalibrated For measurement of kinematic viscosity of small samples of transparent Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Viscometer constant is same at all temperatures Initial sample can be diluted to as much as 20 mL for intrinsic viscosity…
-
Cannon-Fenske Series Viscometers
Cannon Instrument…Require liquid bath depth of 203 mm (8"). Calibrated viscometers are supplied with a certificate of calibration and instruction sheet. Viscometers have the serial number and size printed on the outside of the box and on the viscometer. Additional sizes are available on special order. Holder not…
-
…(9729N22) Calibrated to contain 60 mL; tolerance to 0.05 mL With large hemispherical tip, heavy walls and reinforced rim For ASTM standard D 88; API standard 518; ANSI method Z11.2; AASHTO standard T-72; Federal Test Method Standard No. 791, method 304.7. With spot for marking
-
Bubble Viscometers
BYK-Gardner…speed of a trapped air bubble) Conforms to ASTM D 1131, D 1545 and D 1725 Standard tubes easily identified by large letters Quick and easy cleaning Viscosity of the liquid sealed in each standard is permanently stable. Corked samples may be reserved for future reference and re-measurement…
-
BS/IP/SL(S) Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume:10 mL. Requires liquid bath depth of 230 mm (9”). Includes certificate of…
-
Digital Paddle Viscometers
Cannon Instrument…models (standard and water-cooled), the Digital Paddle Viscometer can also be used for other applications consistent with its temperature control and viscosity measurement capabilities, including the ASTM D 244 consistency test. Ideally suited for field use, the Digital Paddle Viscometer can…
-
ROTAVISC Complete Viscometers
IKA Works… The level of measurement accuracy of the ROTAVISC rotational viscometer for both Newtonian and non-Newtonian fluids is +/- 1 % of the measuring range. The reproducibility is +/- 0.2 %. Stepless speed ROTAVISC is a viscometer, which offers stepless speed adjustment. IKA Rotavisc lo-vi…
-
BS/U Tube Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume: 7 mL in sizes A to C; 12 mL in sizes D to F ; 23 mL in sizes G and H. Requires…
-
Made of polished stainless steel Looped handle and finger ring Calibrated with Cannon viscosity standards traceable to NIST; Cannon standards are produced in accordance with ISO 90002 Each cup is furnished with the mathematical formula for calculating the viscosity in centistokes using…
-
Zeitfuchs Cross-Arm Calibrated Viscometers
Cannon Instrument…according to ASTM Standard D 2170 (see Table 3). Can be filled and cleaned while in constant temperature bath. Minimum sample volume: 1 to 3 mL . Requires liquid bath depth of 230 mm (9"). Individually boxed. Serial number is printed on the outside of the box and on the viscometer. Certificate…
-
SV-A Series Viscometers
A&D Weighing…sensor unit: The sensor unit can be detached from the stand and conveniently used for field research purposes Standard carrying case: A portable carrying case is provided as standard for field research purposes Auto hold function: When the change of the displayed viscosity value is within…
-
…Flow glass capillary viscometers are ideal for the measurement of opaque liquids within a range of 0.6-300,000 cSt. Includes a calibration certificate with Constant values at 40°C and 100°C. Viscometers conform to ASTM D445, D446, ISO 3104, ISO 3105 and UNE 400313 standards. Additional calibration…
-
BS/IP/MSL Miniature Suspended Level Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision:±0.2%. Minimum sample volume:4 mL. Requires liquid bath of 305 mm (12”). Includes certificate of…
-
BS/IP/RF U-Tube Reversed Flow Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of opaque Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.3%. Minimum sample volume: 7 mL. Requires liquid bath depth of 280 mm (11"). Includes certificate…
-
Modified Koppers Vacuum, Cannon Mkvc Series Viscometers
Cannon InstrumentCalibrated viscometers For measuring viscosity of asphalt at 60°C (140°F) Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 42 to 200,000 poises. Two-piece design, with sample reservoir and calibrated capillary Vacuum of 300 mm Hg must be applied to top of capillary…
-
Asphalt Institute Vacuum, Cannon Aivc Series Viscometers
Cannon InstrumentCalibrated viscometers For measuring viscosity of highly viscous materials such as asphalt cement at 60°C (140°F) Meets ASTM D 2171 Applicable to materials with viscosity range of 42 to 5,800,000 poises With graduated capillary to extend viscosity range of viscometer Minimum sample size: 3…
-
Cannon-Ubbelohde, CUU And CUC Series Viscometers
Cannon Instrument…range. Viscometer constant is the same at all temperatures. Specifications conform with ASTM Standard D 446. Minimum sample volume: 11 mL. Require liquid bath depth of 254 mm; must be submerged to approximately 220 mm. Each viscometer is individually boxed. Calibrated viscometers include a…
-
Cannon-Manning Semi-Micro, Cannon CMSMC Series Viscometers
Cannon InstrumentCalibrated Viscometers For measurement of kinematic viscosity of small samples of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 requirements Precision: ±0.2% Specifications conform with ASTM Standard D 446. Minimum sample…
-
Cannon-Manning Vacuum, Cannon CMVC Series Viscometers
Cannon InstrumentCalibrated viscometers For measurement of viscosity of highly viscous materials such as asphalt cement at 140°F Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 0.036 to 80,000 poise. Vacuum of 300 mm Hg is applied to small arm with timing bulbs; two…
-
Cannon Four Bulb Shear Dilution Viscometers
Cannon Instrument…sample volume: 20 mL . Requires liquid bath depth of 280 mm. Individually boxed. Size and serial number are printed on the box and on the viscometer. Holders not included. See Thomas numbers 9726M70, M73 and M76 for holders. For measurement of intrinsic viscosities extrapolated to zero…
-
Standard Spindle
IKA WorksThe standard spindle set SP set-1 includes four spindles (SP1, SP2, SP3, SP4). It is particularly suitable for viscosity determination in combination with the rotary viscometers ROTAVISC lo-vi Complete or ROTAVISC lo-vi Advanced. The standard spindle set SP set-2 includes six spindles (SP7, SP8,…
-
Calibrated viscometers For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F and asphalt…
-
General Purpose Low Temperature Viscosity Standards
Cannon Instrument…Viscosity Standards verify viscometer performance at sub-zero temperatures. These standards are applicable to SAE Specification J300 as well as a variety of ASTM Methods including: ASTM D2983, Low-Temperature Viscosity of Lubricants Measured by Brookfi eld Viscometer ASTM D3829,…
-
…on this page is nominal. All certified values for the current lots of all Paragon CCS Viscosity Standards can be found on the Paragon Scientific webpage.Paragon ISO 17025 / ISO 17034 certified mineral oil rotational viscosity standards are specifically formulated for use with rotational viscometers.
-
Mineral Oil Rotational Viscosity Standards (viscosity 2.144 mPa.s) are specifically formulated for the calibration and verification of rotational viscometers where operating temperature is controlled precisely.
-
Mineral Oil Rotational Viscosity Standards (viscosity 10.37 mPa.s) are specifically formulated for the calibration and verification of rotational viscometers where operating temperature is controlled precisely.
-
Mineral Oil Rotational Viscosity Standards (viscosity 55.68 mPa.s) are specifically formulated for the calibration and verification of rotational viscometers where operating temperature is controlled precisely.
-
Silicone Viscosity Standards
Cannon InstrumentFor calibration of rotational viscometers Viscosity certified at 20, 23, 24, 25, 26 and 27°C Calibrated to a precision of ±0.2% NIST traceable Standards are based on the National Institute of Standards and Technology (NIST) value of 1.0016 mPa-s (centipoise) for water…