  • The sturdier vertical slab gel unit was designed with durability and cost in mind. Injection-moulded of tough, impact-resistant plastics, it will withstand the rigours of daily lab use and teaching labs for years Economical and secure vertical slab electrophoresis units with many of the…

  • Run as many as four 0.75, 1.0, or 1.5 mm thick gels on SE600 Series units and two gels on the SE400 Series at one time under identical conditions. How it works: Insert a divider plate between the glass plates that make up a single gel sandwich. Place spacers on each side of the divider plate to…

  • SE 600 Ruby standard dual cooled vertical unit, complete Run denaturing and native polyacrylamide, 2-D, electrophoresis, agarose, and nucleic acid gel electrophoresis Maintain temperature between 1 and 45°C with built-in heat exchanger for faster runs with no sacrifice in quality Run two gels…

  • electrophoresis unit Choose the SE260 for higher resolution using a 10 x 10.5 cm gel format Run two gels at once in a single unit, and rely on the efficient cooling system to deliver flat, side-by-side sample lanes with no smiling Assemble gel sandwiches and electrophoresis units

  • …7-cm IPG strips in 1.5 hminiVE Convenient design The simple, modular design of miniVE vertical electrophoresis system consolidates all the small parts for electrophoresis and blotting into one convenient unit. Uniform gel temperature is maintained with the tank-style lower buffer chamber. A full…

  • …gradient or homogenous gels to be cast simultaneously Pour uniform gels from the top; pump gradient gels into an inlet port at the bottom of the unit Sandwiches fill at the same time at the same rate from the same solution. The result: identical gels Glass plate sandwiches seal leak…

  • electrophoresis unit Choose the SE 250 for fast results using a 10 x 8 cm mini-gel format Run two gels at once in a single unit, and rely on the efficient cooling system to deliver flat, side-by-side sample lanes with no smiling Assemble gel sandwiches and electrophoresis units

  • …sodium dodecyl sulfate – polyacrylamide gel electrophoresis (SDS-PAGE) of proteins. TGS is usually used for both the anode buffer and the cathode buffer. Recommended running conditions is 150 volts for mini vertical gel electrophoresis units. Reconstitution: Dilution of the 10× TGS…

  • …damaging gels during staining/destaining procedures Large, flat capsule keeps the stirring bar consistently centered on the bottom of vertical electrophoresis units (e.g. Hoefer’s) to efficiently mix the running buffer Use of the capsule prevents the stirring bar from being impeded by…

  • Cast up to 2 gels at once Use with SE 250, SE 260, and miniVE vertical units Cast up to 2 gels at onceUse with SE 250, SE 260, and miniVE vertical units

  • 4-Gel caster 4-Gel caster Convenient design The simple, modular design of miniVE vertical electrophoresis system consolidates all the small parts for electrophoresis and blotting into one convenient unit. Uniform gel temperature is maintained with the tank-style lower buffer chamber. A full tank…

  • DALT Gel

    Cytiva

    Highest capacity electrophoresis unit with the largest precast gels available (26 x 20 cm). Stable, discontinuous buffer system in a precast, homogeneous gel features high batch-to-batch reproducibility. Simple-to-use gel cassettes for gel loading, unloading, and storage. Programmable power…

  • DALT Buffer Kit for 12 Precast Gels Highest capacity electrophoresis unit with the largest precast gels available (26 u 20 cm) Stable, discontinuous buffer system in a precast, homogeneous gel features high batch-to-batch reproducibility Simple-to-use gel cassettes for gel loading, unloading,…

  • DIGE Gel

    Cytiva

    …Kit and Ettan DALT large vertical system. Ettan DALT six is designed for large-format, second dimension electrophoresis using either 18 or 24 cm Immobiline DryStrip Gels. The DIGE Buffer Kit contains the amount of reagents necessary for two runs of up to six gels using the Ettan DALT six unit.

  • …of aqueous solutions ranging in volume from 15–100 ml. The SG 50 and SG 100 units can be used to form convex and concave exponential gradients with the addition of an exponential gradient plunger accessory. The small units (SG 15, SG 30, SG 50, and SG 100) are machined from solid blocks of acrylic…

  • …constant voltage mode is recommended for other applications, such as nucleic acid submarine and mini-vertical gel electrophoresis. When connecting two electrophoresis units to the same power supply, twice as much current is required at the same voltage. To maintain a constant temperature…

  • …up to 12 dige gels can be run simultaneously with separations complete in 4 to 6 h. the dige buffer kit contains the amount of reagents necessary for a single run of up to 12 dige gels using the ettan dalttwelve electrophoresis unit, or two runs of up to six gels using the ettan daltsix unit.