  • Liquid Trap for RapidVap Vacuum Evaporation System

    Labconco

    …that allow the trap to hang on the side of the RapidVap Vacuum System. Alternatively, the bracket serves as a stand to stabilize the glass container resting on a flat work surface. This trap may also be used with pre-2005 CentriVap Cold Traps. Liquid Trap prevents liquid from entering the pump.

  • Whatman VACU-GUARD 150

    GE Healthcare

    traps: activated carbon, molecular sieve, or desiccant. Excellent for protecting vacuum pump systems from solvent vapor or gaseous contaminants and aqueous aerosols. Designed for in-line use with stepped barb connections for 10 to 12 mm i.d. hose. Available with choice of chemical trap:

  • Laboratory High Vacuum Pump

    Fischer Technical

    …from vacuum system          Trap:     Reduces risk of oil sucked back into the system This direct drive pump provides the best Performance/Cost Ratio available today. Comes complete with initial supply of High Vacuum Pump Oil. …

  • Vacuum Inlet Traps

    HYVAC

    Protect vacuum pumps from foreign materials by ensuring the highest quality air is entering the pump Plastic transparent sump shows when to change filter insert Simple to maintain-change filter inserts without removing trap from vacuum system 4.5 inch trap serves vacuum pumps up to…

  • Whatman VACU-GUARD

    GE Healthcare

    …in vacuum systems and protect the laboratory. Excellent for protecting vacuum pump systems from solvent vapor or gaseous contaminants and aqueous aerosols. Designed for in-line use with stepped barb connections for 10 to 12 mm i.d. hose. Available with choice of chemical trap: activated…

  • Secondary Vacuum Trap, 2L, 9-3/4" X 7-7/8" With 1/2" Connection

    Labconco

    Trap connects in series with a freeze dry system or vacuum evaporation system and vacuum pump to prevent contaminants from migrating into the vacuum pump. An insulated well, when dry ice and solvent are added, cools to approximately -75° C (-103° F). When used alone, Dry Ice Secondary Trap

  • Complete Vacuum Traps with 3/8" Hose Connections

    Wilmad LabGlass

    Widely used to protect vacuum pumps from contamination, these borosilicate glass vacuum traps are a one piece unit with two 3/8" hose connectors. Connectors are 180° apart to ease connection of heavy wall rubber tubing used in basic vacuum set-ups. These traps are frequently used with…

  • Rotavapor® R-100 Rotary Evaporator

    Buchi

    …bottle Vacuum Pump: V-100, 1.5 m3/h, 10 mbar 1190U73 Glass Assembly: C (Cold trap) for low boiling point solvents Protective Coating: Without Recirculating Chiller: F-100, fix +10 °C, 400 W Vacuum Controller: I-100, with Woulff bottle Vacuum Pump: V-100, 1.5…

  • Buchi Vacuum Pump V-700 & V-710 Accessories

    Buchi

    …the pump. 1230D90 - Secondary Condenser Vaccum Pump V-700/710 compact high performance condenser for producing maximum condensation of residual solvent vapor after the pump. 1230D91 - Secondary Cold Trap, If dry ice is used instead of cooling water, a suitable cold trap can also…

  • Vacuum Trap Com Size 21

    DWK Life Sciences (Kimble)

    Outlets are 180º apart for easy installation into a variety of vacuum systems. Protects the mechanical pump from attack by corrosive vapors which can be condensed by using liquid nitrogen or dry ice/slurry mixtures. Two-piece construction allows removal of condensate.

  • Dry Ice Trap 1/2' Inlet / Outlet

    Welch

    Dry Ice Cold Traps are recommended for pumps when doing rotary evaporation, drying solvents, vacuum distillation, centrifugal concentration or any other process involving volatile solvents. 2.8 L center well that holds a dry-ice and alcohol slurry capable of producing temperatures as low as…

  • CA Series Cold Traps

    Yamato

    traps water vapor and toxic substances discharged from vacuum oven and rotary evaporator to protect the vacuum pump Features Excellent choice to extract acid and organic solvents with the optional glass condenser Efficiently reduces vapor inhalation amount to the vacuum pump Can…

  • Direct Drive Vacuum Pumps

    Welch

    Compact, convenient Deep vacuum Use these Welch 2-stage direct drive pumps for a wide range of laboratory applications to provide deep vacuum down to 1 x 10-4 torr. Common lab processes include freeze drying, vacuum oven drying, glove box vacuum, centrifugal concentrator operation, and…

  • DuoSeal® High Vacuum Pumps

    Welch

    …and pump life. Large oil reservoir minimizes contaminant effects to maintain high vacuum performance. Use of a cold trap is recommended to protect the pump and enhance vacuum levels. Do not operate continuously at pressures greater than 10 torr. DuoSeal two stage pumps provide deep vacuum (1 X…

  • Vacuum Pump V-100

    Buchi

    …Rotavapor® R-100. The ready to use vacuum pump will be delivered with a silencer and 2m of vacuum tubing. All Models Capacity, Final Vacuum 1.5 m3/h, 10 mbar 1190U86 Condensation assembly: Secondary cold trap Vacuum Controller: I-100 (Manual, Timer) Woulff…

  • CentriVap Cold Trap

    Labconco

    The CentriVap Cold Trap collects evaporated liquid from a CentriVap Concentrator, protecting an accessory vacuum pump from the corrosive effects of vapors and fumes emitted from samples. Exclusive features include: brushed, stainless steel and glacier white, epoxy-coated steel exterior with blue…

  • Standard Duty Dry Vacuum Pump

    Welch

    …Select vacuum range 100 to 5 torr; flow range 22 to 201 l/min. For use with dry or aqueous vapor applications only. Includes Vacuum and Pressure Regulators and Gauges - simple monitoring and adjustment of vacuum level and delivery pressure. Inlet Water Trap - float ball rises to seal off pump

  • Buchi V-850/855 Vacuum Controller Accessories

    Buchi

    1229D81 - Buchi V-850/855 Vacuum Controller Valve combined with condensate trap and non-return valve with attachment for Rotavapor (not necessary with V-700/710 in stand-alone systems). 1229D82 - Buchi RC-81 remote control can be used to control the vacuum controller and the Rotavapor:…

  • Buchi Vacuum Pump V-700/710 Secondary Condenser

    Buchi

    …after the pump. 1230D90 - Secondary Condenser Vaccum Pump V-700/710 compact high performance condenser for producing maximum condensation of residual solvent vapor after the pump. 1230D91 - Secondary Cold Trap, If dry ice is used instead of cooling water, a suitable cold trap can also…

  • High Vacuum System Trap

    Ace Glass

    Vacuum trap system protects gauge heads, like our 14034, and pumps from corrosive vapors and particle fouling. System consists of a Dewar flask, cold trap and inlet arm. High-vacuum stopcocks are used throughout. Gauge & inlet arm are Ace-Thred connections. Pump & manifold connections are o-ring…

  • SYNTHWARE Vacuum Trap

    Kemtech America

    For use with vacuum manifolds having 35/20 socket joints. Please order the pump adapter and socket clamp separately.

  • Aspirator with Trap Flask

    Grant Instruments

    The aspirator with trap flask FTA-1 with a 1L trap flask is designed for the aspiration or removal of any remaining alcohol or buffer from microtest tube walls during DNA / RNA purification and other macromolecule re-precipitation techniques. An ideal personal tool for independent operation…

  • Rocker Vacuum Pumps

    Restek

    vacuum pumps are piston powered, so they do not pollute the air and require minimal maintenance Quiet, low-vibration units keep disturbances to a minimum Built-in thermal protector automatically shuts off pump if it overheats and then restarts it once the unit is cool Inlet filter traps

  • Self-Cleaning Dry Vacuum System

    Welch

    …PTFE pump. All wettable parts, including the diaphragm and valves are PTFE. Vacuum level regulator and built-in dial guage allow easy control of pressure to prevent sample bumping or foaming. Switchable gas ballast inhibits vapor condensation inside pump heads. An inlet separator traps ejected…

  • PILOT5000 Chemical Resistant Diaphragm Vacuum Pumps

    Fischer Technical

    …PILOT5000 and PILOT5000C-02 diaphragm vacuum pump are durable and chemical resistant. All contact surfaces are PTFE coated. They come with a liquid inlet trap and vacuum regulator making it a perfect choice for vacuum filtration, desiccation, and other mid-range vacuum applications. The TLD5000 and…

  • Vacuum Pump

    Dynalon

    …(l x w x h) : 9.5x3.125x1.375in For generating vacuum and extracting liquids and vapors*. Designed for excellent performance: Very low water consumption, constant ultimate pressure and high suction capacity . Pump fluid: water Overall length: approximately 210 mm (R 3/4''…

  • Centrifan™ PE Personal Evaporator/Condenser, Rotors for Centrifan PE and PE-T,…

    KD Scientific

    …technique eliminates the need for a vacuum pump or a large supply of blow down gas, significantly reducing cost, complexity, noise, andmaintenance compared to rotary evaporators, vacuumcentrifuges, and conventional blow-down equipment. Because it operates without vacuum, the Centrifan PE eliminates…

  • Gelmaster Gel Dryer Vacuum System

    Welch

    …room temperature vapor pump and trap to condense and remove hot vapors and a high-efficiency, dry vacuum diaphragm pump for deep drying. Two pump system works as quickly as a two stage vacuum pump but requires no cold trap for vapor removal. Supplied with one liter of trapping medium that does not…

  • Soda Acid Trap

    Labconco

    Secondary trap connects in series with freeze dry system and vacuum pump to prevent migration of corrosive chemicals into pump interior. Clear acrylonitrile body allows visual check of color indicating media. Media changes from white to blue when exhausted. 3/4" OD inlet and outlet connections.…

  • Vacuum Pump Accessories

    Welch

    …contaminants in pump oil. 1169A97: Outlet Oil Mist Separator Outlet oil separator removes oil particles from exhaust stream, minimizing oil loss to atmosphere. 1169A98: Oil Mist Filter Use oil mist filter on CRVpro4, CRVpro6, and CRVpro8. Oil mist filter traps oil before it's…

  • Vacuum Trap Size 21

    DWK Life Sciences (Kimble)

    Connections are 180º apart for easy installation into a variety of vacuum systems. Protects the mechanical pump from attack by corrosive vapors which can be condensed by using liquid nitrogen or dry ice/slurry mixtures.

  • Centrivap DNA Concentrator

    Labconco

    …rotor, diaphragm, vacuum pump, two glass traps and all connecting tubing. Large chamber and rotors hold more samples. Integrated diaphragm pump is corrosion-resistant. DNA rotor holds up to 60 x1.5 mL tubes and 72 x 0.5 mL tubes. Two 177 mL glass traps protect the vacuum pump and the environment.…