Vacuum Pump Trap

Compare Tool

Select up to 3 products

Vacuum Pump Trap
1 - 32 of 86
Sort
View
Show
  • MilliporeSigma

    When installed between a Visiprep SPE vacuum manifold and the vacuum source, a Supelco SPE Vacuum Pump Trap collects all liquids that are aspirated through the SPE tubes, preventing contamination of the vacuum pump. The easily assembled kit contains a polypropylene filtering flask, a one-hole rubber…

  • Vacuum trap system protects gauge heads, like our 14034, and pumps from corrosive vapors and particle fouling. System consists of a Dewar flask, cold trap and inlet arm. High-vacuum stopcocks are used throughout. Gauge & inlet arm are Ace-Thred connections. Pump & manifold connections are o-ring…

  • Kemtech America

    For use with vacuum manifolds having 35/20 socket joints. Please order the pump adapter and socket clamp separately.

  • DWK Life Sciences (Kimble)

    Connections are 180º apart for easy installation into a variety of vacuum systems. Protects the mechanical pump from attack by corrosive vapors which can be condensed by using liquid nitrogen or dry ice/slurry mixtures.

  • …Rotavapor® R-100. The ready to use vacuum pump will be delivered with a silencer and 2m of vacuum tubing. All Models Capacity, Final Vacuum 1.5 m3/h, 10 mbar 1190U86 Condensation assembly: Secondary cold trap Vacuum Controller: I-100 (Manual, Timer) Woulff…

  • …contaminants in pump oil. 1169A97: Outlet Oil Mist Separator Outlet oil separator removes oil particles from exhaust stream, minimizing oil loss to atmosphere. 1169A98: Oil Mist Filter Use oil mist filter on CRVpro4, CRVpro6, and CRVpro8. Oil mist filter traps oil before it's…

  • quick-ship

    Fischer Technical

    …from vacuum system          Trap:     Reduces risk of oil sucked back into the system This direct drive pump provides the best Performance/Cost Ratio available today. Comes complete with initial supply of High Vacuum Pump Oil. …

  • DWK Life Sciences (Kimble)

    Outlets are 180º apart for easy installation into a variety of vacuum systems. Protects the mechanical pump from attack by corrosive vapors which can be condensed by using liquid nitrogen or dry ice/slurry mixtures. Two-piece construction allows removal of condensate.

  • Pumps that use oil either as their working fluid (diffusion pumps), or as their lubricant (mechanical rotary pumps), are often the sources of contamination in vacuum systems. Placing a cold trap at the mouth of such a pump greatly lowers the risk that oil vapors will back stream into the vacuum

  • …that allow the trap to hang on the side of the RapidVap Vacuum System. Alternatively, the bracket serves as a stand to stabilize the glass container resting on a flat work surface. This trap may also be used with pre-2005 CentriVap Cold Traps. Liquid Trap prevents liquid from entering the pump.

  • …placed between the main and pre-trap to permit connection of vacuum measurement device via a AF-0306-01 thermocouple adapter. Both traps can be isolated from the manifold or pump via 0-12mm Chem-Vac™; Chem-Cap®; valves (H). Trap assembly is designed to allow connection to either the right…

  • …after the pump. 1230D90 - Secondary Condenser Vaccum Pump V-700/710 compact high performance condenser for producing maximum condensation of residual solvent vapor after the pump. 1230D91 - Secondary Cold Trap, If dry ice is used instead of cooling water, a suitable cold trap can also…

  • …the pump. 1230D90 - Secondary Condenser Vaccum Pump V-700/710 compact high performance condenser for producing maximum condensation of residual solvent vapor after the pump. 1230D91 - Secondary Cold Trap, If dry ice is used instead of cooling water, a suitable cold trap can also…

  • …and pump life. Large oil reservoir minimizes contaminant effects to maintain high vacuum performance. Use of a cold trap is recommended to protect the pump and enhance vacuum levels. Do not operate continuously at pressures greater than 10 torr. DuoSeal two stage pumps provide deep vacuum (1 X…

  • …cooler running and longer service life. ChemStar pumps rotate at speeds less than 580 RPM, compared with over 1700 RPM of direct-drive vacuum pumps. Dry Nitrogen Purge both degasses and cools the pump oil reducing the corrosion rate in the pump. Accessories (available on special order): Protective…

  • …returns trapped pump oil back to the pump and makes pumps much quieter to run. Comes with one replaceable filter element (installed), one KF25 clamp and one centering ring. SMF-020: EZ-Swap Large Capacity Pump Exhaust Oil Mist Filter w/ Fittings Our EZ-Swap large capacity series vacuum pump

  • vacuum pumps are piston powered, so they do not pollute the air and require minimal maintenance Quiet, low-vibration units keep disturbances to a minimum Built-in thermal protector automatically shuts off pump if it overheats and then restarts it once the unit is cool Inlet filter traps

  • …KNF vacuum pump and the laboratory device, this trap improves solvent recovery, pump reliability, eliminates downtime by preventing excessive liquid condensate from reaching the pump, and reduces the amount 057953 The KNF Woulfe bottle is a combination vacuum regulator and trap. Offered…

  • Widely used to protect vacuum pumps from contamination, these borosilicate glass vacuum traps are a one piece unit with two 3/8" hose connectors. Connectors are 180° apart to ease connection of heavy wall rubber tubing used in basic vacuum set-ups. These traps are frequently used with…

  • …Resistance. The integral MZ2C diaphragm vacuum pump of the MZ2C NT+2AK vacuum pump features PTFE diaphragms and a fluoropolymer flowpath for excellent corrosion resistance. Catchpots are made of borosilicate glass. Many applications do not require a cold trap. Quiet, Trobule-Free Operation. …

  • Holland Green Science

    …entering the vacuum pump, where they would condense, contaminate vacuum pump oils and can cause corrosion. Whilst doing this task the cold trap further prevents vacuum pump oil from streaming back into the vacuum chamber thus preventing potential product hydrocarbon contamination. Cold traps also…

  • Across International

    …9 CFM vacuum pump is now 110V/220V 50/60Hz switchable! Ai EV9 are dual-stage high speed sliding-vane rotary compact vacuum pump with KF25 vacuum connector. Comes with all necessary fittings and a exhaust oil mist filter which also returns trapped pump oil back to the pump and makes the pump

  • Across International

    …sliding-vane rotary compact vacuum pump with 3/8" hose barb vacuum connector. Comes with a 3-foot food grade silicone hose and a exhaust oil mist filter which also returns trapped pump oil back to the pump and makes the pump quieter to run. It is important to note that pumps should always be…

  • The CentriVap Cold Trap collects evaporated liquid from a CentriVap Concentrator, protecting an accessory vacuum pump from the corrosive effects of vapors and fumes emitted from samples. Exclusive features include: brushed, stainless steel and glacier white, epoxy-coated steel exterior with blue…

  • Jeio Tech

    …    Alarm if set temperature deviation outside of acceptable range. Vacuum Oven Use Configuration     It is recommended to use the cold trap bath on the vacuum line to protect the weak vacuum pump against water/solvent or to supply dry air to the sample.

  • Grant Instruments

    The aspirator with trap flask FTA-1 with a 1L trap flask is designed for the aspiration or removal of any remaining alcohol or buffer from microtest tube walls during DNA / RNA purification and other macromolecule re-precipitation techniques. An ideal personal tool for independent operation…

  • The Acid Neutralization Trap contains a large alkaline element cartridge to neutralize hydrous acids before they enter the vacuum pump. The element changes from white to bluish-transparent when spent and can be observed through the transparent trap body.

  • …at once, and pumps with deeper vacuum capacity will assist with your evaporative applications. When using the Mini-Network for evaporations, ask about our pumps—like the PC 201 NT—with inlet catchpots to protect your pump from line condensations, and emissions condensers to trap waste vapors…

  • The Acid Neutralization Trap contains a large alkaline element cartridge to neutralize hydrous acids before they enter the vacuum pump. The element changes from white to bluish-transparent when spent and can be observed through the transparent trap body.

  • Trap is designed for large volume solvent vapor removal during rotary evaporation. Trap is placed between the vacuum source and the rotary evaporator to prevent solvent vapors from entering the vacuum pump. PLASTIC COATED to contain solvent in case of breakage and supplied complete with a…

  • …minimum. Built-in thermal protector automatically shuts off pump if it overheats and then restarts it once the unit is cool. Applications include filtration for air sampling, microbiology, suspended solid test, and vacuum oven. Inlet filter traps particles and removes moisture, prolonging pump life.

  • …Savant SpeedVac vacuum concentrators, refrigerated vapor traps and pumps use state-of-the-art centrifugation, vacuum and heat technologies for removing solvents and concentrating samples while maintaining sample integrity. Choose from any of the nine different models of vacuum concentrator to suit…

Compare Tool

Select up to 3 products