Vacuum Pump Trap
-
SPE Vacuum Pump Trap Kit
MilliporeSigmaWhen installed between a Visiprep SPE vacuum manifold and the vacuum source, a Supelco SPE Vacuum Pump Trap collects all liquids that are aspirated through the SPE tubes, preventing contamination of the vacuum pump. The easily assembled kit contains a polypropylene filtering flask, a one-hole rubber…
-
High Vacuum System Trap
Ace GlassVacuum trap system protects gauge heads, like our 14034, and pumps from corrosive vapors and particle fouling. System consists of a Dewar flask, cold trap and inlet arm. High-vacuum stopcocks are used throughout. Gauge & inlet arm are Ace-Thred connections. Pump & manifold connections are o-ring…
-
SYNTHWARE Vacuum Trap
Kemtech AmericaFor use with vacuum manifolds having 35/20 socket joints. Please order the pump adapter and socket clamp separately.
-
Vacuum Trap Size 21
DWK Life Sciences (Kimble)Connections are 180º apart for easy installation into a variety of vacuum systems. Protects the mechanical pump from attack by corrosive vapors which can be condensed by using liquid nitrogen or dry ice/slurry mixtures.
-
Vacuum Pump V-100
Buchi…Rotavapor® R-100. The ready to use vacuum pump will be delivered with a silencer and 2m of vacuum tubing. All Models Capacity, Final Vacuum 1.5 m3/h, 10 mbar 1190U86 Condensation assembly: Secondary cold trap Vacuum Controller: I-100 (Manual, Timer) Woulff…
-
Vacuum Pump Accessories
Welch…contaminants in pump oil. 1169A97: Outlet Oil Mist Separator Outlet oil separator removes oil particles from exhaust stream, minimizing oil loss to atmosphere. 1169A98: Oil Mist Filter Use oil mist filter on CRVpro4, CRVpro6, and CRVpro8. Oil mist filter traps oil before it's…
-
Laboratory High Vacuum Pump
Fischer Technical…from vacuum system Trap: Reduces risk of oil sucked back into the system This direct drive pump provides the best Performance/Cost Ratio available today. Comes complete with initial supply of High Vacuum Pump Oil. …
-
Vacuum Trap Com Size 21
DWK Life Sciences (Kimble)Outlets are 180º apart for easy installation into a variety of vacuum systems. Protects the mechanical pump from attack by corrosive vapors which can be condensed by using liquid nitrogen or dry ice/slurry mixtures. Two-piece construction allows removal of condensate.
-
Glass Vacuum Cold Trap for Safe Vacuum Operations
Across International… Pumps that use oil either as their working fluid (diffusion pumps), or as their lubricant (mechanical rotary pumps), are often the sources of contamination in vacuum systems. Placing a cold trap at the mouth of such a pump greatly lowers the risk that oil vapors will back stream into the vacuum…
-
…that allow the trap to hang on the side of the RapidVap Vacuum System. Alternatively, the bracket serves as a stand to stabilize the glass container resting on a flat work surface. This trap may also be used with pre-2005 CentriVap Cold Traps. Liquid Trap prevents liquid from entering the pump.
-
…placed between the main and pre-trap to permit connection of vacuum measurement device via a AF-0306-01 thermocouple adapter. Both traps can be isolated from the manifold or pump via 0-12mm Chem-Vac™; Chem-Cap®; valves (H). Trap assembly is designed to allow connection to either the right…
-
…after the pump. 1230D90 - Secondary Condenser Vaccum Pump V-700/710 compact high performance condenser for producing maximum condensation of residual solvent vapor after the pump. 1230D91 - Secondary Cold Trap, If dry ice is used instead of cooling water, a suitable cold trap can also…
-
…the pump. 1230D90 - Secondary Condenser Vaccum Pump V-700/710 compact high performance condenser for producing maximum condensation of residual solvent vapor after the pump. 1230D91 - Secondary Cold Trap, If dry ice is used instead of cooling water, a suitable cold trap can also…
-
…and pump life. Large oil reservoir minimizes contaminant effects to maintain high vacuum performance. Use of a cold trap is recommended to protect the pump and enhance vacuum levels. Do not operate continuously at pressures greater than 10 torr. DuoSeal two stage pumps provide deep vacuum (1 X…
-
Chemstar Vacuum Pumps
Welch…cooler running and longer service life. ChemStar pumps rotate at speeds less than 580 RPM, compared with over 1700 RPM of direct-drive vacuum pumps. Dry Nitrogen Purge both degasses and cools the pump oil reducing the corrosion rate in the pump. Accessories (available on special order): Protective…
-
Rocker Vacuum Pumps
Restek…vacuum pumps are piston powered, so they do not pollute the air and require minimal maintenance Quiet, low-vibration units keep disturbances to a minimum Built-in thermal protector automatically shuts off pump if it overheats and then restarts it once the unit is cool Inlet filter traps…
-
EZ-Swap Vacuum Pump Exhaust Oil Mist Filters
Across International…returns trapped pump oil back to the pump and makes pumps much quieter to run. Comes with one replaceable filter element (installed), one KF25 clamp and one centering ring. SMF-020: EZ-Swap Large Capacity Pump Exhaust Oil Mist Filter w/ Fittings Our EZ-Swap large capacity series vacuum pump…
-
Pump Accessories
KNF…KNF vacuum pump and the laboratory device, this trap improves solvent recovery, pump reliability, eliminates downtime by preventing excessive liquid condensate from reaching the pump, and reduces the amount 057953 The KNF Woulfe bottle is a combination vacuum regulator and trap. Offered…
-
Complete Vacuum Traps with 3/8" Hose Connections
SP Wilmad-LabGlassWidely used to protect vacuum pumps from contamination, these borosilicate glass vacuum traps are a one piece unit with two 3/8" hose connectors. Connectors are 180° apart to ease connection of heavy wall rubber tubing used in basic vacuum set-ups. These traps are frequently used with…
-
Aquilon Cold Trap
Holland Green Science…entering the vacuum pump, where they would condense, contaminate vacuum pump oils and can cause corrosion. Whilst doing this task the cold trap further prevents vacuum pump oil from streaming back into the vacuum chamber thus preventing potential product hydrocarbon contamination. Cold traps also…
-
Ai EasyVac Dual-Stage Vacuum Pumps
Across International…9 CFM vacuum pump is now 110V/220V 50/60Hz switchable! Ai EV9 are dual-stage high speed sliding-vane rotary compact vacuum pump with KF25 vacuum connector. Comes with all necessary fittings and a exhaust oil mist filter which also returns trapped pump oil back to the pump and makes the pump…
-
Ai EasyVac Compact Vacuum Pumps
Across International…sliding-vane rotary compact vacuum pump with 3/8" hose barb vacuum connector. Comes with a 3-foot food grade silicone hose and a exhaust oil mist filter which also returns trapped pump oil back to the pump and makes the pump quieter to run. It is important to note that pumps should always be…
-
CentriVap Cold Trap
LabconcoThe CentriVap Cold Trap collects evaporated liquid from a CentriVap Concentrator, protecting an accessory vacuum pump from the corrosive effects of vapors and fumes emitted from samples. Exclusive features include: brushed, stainless steel and glacier white, epoxy-coated steel exterior with blue…
-
Air Pump
Gast…operation Free air displacement 1.3 cfm (37 Lpm) Stainless steel pump valves; aluminum cylinder and piston parts Equipped with safety pressure relief valve, intake filter and moisture trap, vacuum and pressure gauges, serrated tubing connector on inlet and outlet and carrying…
-
Aspirator with Trap Flask
Grant InstrumentsThe aspirator with trap flask FTA-1 with a 1L trap flask is designed for the aspiration or removal of any remaining alcohol or buffer from microtest tube walls during DNA / RNA purification and other macromolecule re-precipitation techniques. An ideal personal tool for independent operation…
-
Cascade Dry Ice Trap
Cascade Sciences LLC…with this “ice bucket” style cold trap. Fill the internal stainless-steel reservoir with a cold slurry mix of ice/ alcohol/ dry ice and set inside the larger steel vessel. The cold surface of the trap attracts and condenses material that would otherwise be ingested by the vacuum pump.
-
Trap is designed for large volume solvent vapor removal during rotary evaporation. Trap is placed between the vacuum source and the rotary evaporator to prevent solvent vapors from entering the vacuum pump. PLASTIC COATED to contain solvent in case of breakage and supplied complete with a…
-
Ai WaterVac 2-Head Recirculating Water Vacuum Pumps
Across International…2-head recirculating water pump, with simplified maintenance, and no frequent and costly oil change. All major parts are made of PTFE, these economical vacuum pumps are perfect for tough lab applications. Free three feet 3/8" white premium food grade silicone vacuum tubing ($19.99 value)…
-
…Select vacuum range 100 to 5 torr; flow range 22 to 201 l/min. For use with dry or aqueous vapor applications only. Includes Vacuum and Pressure Regulators and Gauges - simple monitoring and adjustment of vacuum level and delivery pressure. Inlet Water Trap - float ball rises to seal off pump…
-
PILOT5000 Chemical Resistant Diaphragm Vacuum Pumps
Fischer Technical…PILOT5000 and PILOT5000C-02 diaphragm vacuum pump are durable and chemical resistant. All contact surfaces are PTFE coated. They come with a liquid inlet trap and vacuum regulator making it a perfect choice for vacuum filtration, desiccation, and other mid-range vacuum applications. The TLD5000 and…
-
Fi-Streem Digital Vacuum Ovens
LabStrong…intervals) Vacuum Controls Vacuum gauge and valves conveniently located near bottom of front panel allow for convenient connection to vacuum pump, vapor trap or exhaust Reliable, needle type inlet and exhaust valves Serrated nozzles accept flexible vacuum tubing of .39 to .47…
-
…PTFE pump. All wettable parts, including the diaphragm and valves are PTFE. Vacuum level regulator and built-in dial guage allow easy control of pressure to prevent sample bumping or foaming. Switchable gas ballast inhibits vapor condensation inside pump heads. An inlet separator traps ejected…