  • Vacuum Manifold

    Cannon Instrument

    With three or four manual valves for applying vacuum or pressure to capillary-type viscometers Designed for use with 9726T20 through 9726T67 Vacuum Regulators and Cannon-Manning, Asphalt Institute or Modified Koppers vacuum viscometers (see Thomas number 9724H50) Integral brackets permit…

  • …universal robotic manifold can operate with many different brands of filter plates and collection trays.  Supplied with integral vacuum gauge, the manifold provides complete control of vacuum pressure ensuring plates are processed with high reproducibility.  The manifold is fully…

  • Vacuum Manifolds

    Chemglass

    General purpose single bank vacuum manifold with 3, 4, or 5 ports. Main tube is 38mm OD with a serrated hose connection, having the smallest serration 13.5mm and the largest serration 15.5mm, located at either the left or right side for vacuum connection. Ports are either 0-4mm or 0-8mm…

  • Accessories for Combisart and Microsart Combi.jet Vacuum Manifolds.

  • BioVac 96 Vacuum Manifold instument that extracts 96 samples of DNA/RNA/Genomic DNA in short amount of time.

  • Double Vacuum Manifold

    SP Wilmad-LabGlass

    This borosilicate glass Air-Tite vacuum gas manifold (Schlenk line) is designed with double oblique pressure/vacuum stopcocks with 4mm bores and a 16.2/56 plug size. The stopcocks simplify evacuation or pressurization with an inert atmosphere. Manifold is 1" O.D.

  • EZ-Vac™ Vacuum Manifold

    Zymo Research Corporation

    The EZ-Vac™ Vacuum Manifold features durable chemical-resistant construction and is capable of processing up to 20 samples simultaneously using vacuum pressure. The vacuum manifold allows researchers to simplify their nucleic acid purification workflows further by eliminating the need for…

  • manifold can accomodate 90mm holders. Use 47mm or smaller holder units on the 6-place model. Valves have a PTFE stopcock. Available with 2-way or 3-way valves. Use the 3-way valve when the manifold is used under closed conditions and must be vented to the atmosphere without breaking the vacuum

  • E-Z 96® Vacuum Manifold

    Omega Bio-tek

    The E-Z 96 Vacuum manifold is designed for DNA/RNA sample preparation with E-Z 96 DNA/RNA Plates. The chamber can be used either as a simple dump for waste filtrate or as a receptacle for a standard 96-well microtiter plate (collection plate). The upper plate has a machined recess that fits our…

  • Stainless Steel Vacuum Manifold

    Thermo Scientific Nalgene

    Nalgene 345 Solid and stable on the bench top Designed with three vacuum outlets, each with leakproof, two-way valve and vent port Each outlet securely holds a No. 8 stopper and the stem filter funnel without interference Autoclavable Easy manipulation of individual funnels…

  • Vacuum Manifold Accessories

    Agilent Technologies

  • For simultaneous preparation of up to 12, 16 or 24 samples

  • Aluminum Vacuum Manifolds

    Dun-Rite Machining

    …Designed to be used in the vacuum filtration of liquids for analysis of microbiological or particulate contamination. Manifold accommodates both 25 and 47 mm filter funnels. Increase laboratory productivity by processing multiple samples simultaneously. Aluminum manifold is especially suited for…

  • General purpose single bank vacuum manifold with 4 or 6 ports. Main tube is 1" OD with a serrated hose connection, having the smallest serration 13.5mm and the largest serration 15.5mm, located at either the left or right side for vacuum connection. Ports are 4mm PTFE stopcocks with serrated…

  • Stainless Steel Vacuum Manifolds

    GVS Filter Technology

    Vacuum manifold used for filtration and analysis of liquid samples Stainless steel filter funnel manifold, for use with microbiology monitors, analytical funnels and general filtration. Features and Benefits Durable Stainless Steel construction for easy cleanup and…

  • …pipettors facilitates a manual liquid transfer. Extraction is carried our using the CHROMABOND® MULTI 96 vacuum manifold. With the help of the control valve the vacuum of the manifold can be adjusted leading to an optimum flow rate through the CHROMABOND® MULTI 96 SPE plate. A reservoir…

  • General purpose manifold with 2mm or 4mm Teflon® stopcocks. Main tube is 22mm O.D. with serrated hose connection (10mm O.D.). Delivery ports have 10mm serrated hose connections. Distance between stopcocks is 75mm.

  • …complete with the necessary O-ring and gasket. The control block includes the vacuum pressure gauge, vacuum metering valve, vacuum release valve, and 1⁄4 in. hose barb for vacuum line attachment. Vacuum manifold unit includes a Delrins spacer block designed to accommodate standard 350 μL…

  • With a serrated hose connection (10mm O.D.) at left or right hand side. Main tube is 22mm O.D. and the distance between valves is 100mm center to center.

  • Similar to the CG-4440 vacuum manifold, but with BOTH ENDS OF INERT GAS LINE OPEN to permit connection to the gas source and an oil bubbler. Hose connections have a 10mm small serration and a 11mm large serration.

  • Special Vacuum Apparatus that can be used as a complex trap with the bottom tube or as a small manifold by itself. Can be joined to ACE 8737,8738 or 8739 manifolds or as a stand alone manifold. The code -23 consists of the -03 manifold and our 8753-21 tube, making a trap unit. It has a 15mm o-ring…

  • Manifold, Vacuum

    Ace Glass

    All-glass-and-PTFE vacuum manifold with three, four or five stopcock ports. Each port is a variable opening, 0-10mm, high vacuum threaded stopcock. Plugs are PTFE with Nylon or PTFE handles and FETFE O-Rings. Ultimate vacuum of 10-7 can be realized with O-Rings as supplied. For bakable systems,…

  • Manifold, Vacuum

    Ace Glass

    Glass Manifold with #15 Ace-Thred at either end To allow switching 5853 vacuum connection to left or right side. Supplied with three or five, 4mm straight bore PTFE stopcock sampling ports. (Additional ports can be ordered.) Overall length of glass manifold is 230mm. Complete item consists of 8763…

  • SPE Vacuum Manifolds allow you to process up to 24 samples simultaneously while seamlessly integrating with columns.

  • SPE Vacuum Manifolds accommodate either 12 or 24 cartridges; 1, 3, 6, 15 and 25 mL columns can be used. Manifolds are equipped with a vacuum port to connect a standard laboratory vacuum pump. Vacuum pulls the sample through the stationary phase, metered by the stopcocks, to control the speed of the…

  • …bank vacuum manifold with 0-8mm Chem-Vac™ Chem-Cap® valves mounted on a 45° angle to the user permitting easy operation inside of a fume hood. Ports are spaced 75mm center to center. All connection ports are #15 o-ring connections that incorporate a greasefree o-ring seal. Manifold is…

  • …extractions. Unlike other vacuum manifolds, the Visiprep system contains a patented valve system that allows for precise flow control through each SPE tube via rotating, independent, screw-type valves situated in each port within the manifold cover. Visiprep vacuum manifolds allow you to process up…

  • …design, double bank manifold with the valves sealed in a vertical position. This design permits the user an unobstructed view of whether the valve is in the open or closed position while also exposing the PTFE valves to less outgassing (when the front bank of the manifold is used for inert gas).…

  • Double bank manifold available in 3, 4 or 5 port configuration. Forward facing 0-8mm Chem-Vac™ Chem-Cap® valves permit easy operation of manifold inside of a fume hood. Main ports are spaced 100mm center to center with an additional 2 ports on the upper bank that can be used for gauging or…