Thermometer Adapter
RPI Research Products
-
PYREX Thermometer Adapter
CorningPYREX® thermometer adapters have a Standard Taper ground joint at one end while the other end is tooled to accommodate a thermometer. The adapter comes with a rubber thermometer holder.
-
Synthware Thermometer Adapters
Kemtech AmericaSynthware thermometer adapter with a 5 degree offset and a serrated hose connection for vacuum. Joints are standard taper.
-
Scienceware® PTFE Thermometer Adapters
SP Bel-Art…top of body threaded to take thermometer adapter or vacuum adapter. Thermometer adapter has threaded cap with port to take thermometer, glass tubing or similar objects, up to 6 mm o.d. Viton® O-rings seal against thermometer and against mouth of body. Vacuum adapter has serrated Teflon tubing…
-
PTFE Thermometer Adapters
Across InternationalThermometer adapter with PTFE body and Viton® O-ring for air tight vacuum work. Features Adapter has a threaded polypropylene screw cap on top with an inside O-ring for depth adjustment of 6-7mm for straight stem thermometers, glass tubing and other items Rotating the extracting…
-
SYNTHWARE Thermometer Adapter with Hose Connection
Kemtech AmericaThermometer Adapter, Vacuum, Microscale, Synthware, Joints: 14/10, Thermometer OD: 5.0-7.5mm, supplied with one compression cap and one Viton O-ring.
-
Adapter, Thermometer
Ace GlassInner joint at bottom and 10/30 outer joint at top which is offset and angled for use in multiple neck flasks.
-
Adapter, Thermometer
Ace GlassAdapter, standard taper joint, 13mm OD center tube with bead,6mm OD tube end side arm.
-
PTFE Thermometer Adapters with Compression Cap
SP Wilmad-LabGlassThese PTFE inner joint adapters have a threaded compression cap, four saddle O-rings and one Viton® O-ring for use with plain stem thermometers and inlet tubes. Accepts thermometers with O.D.'s from 3 to 7mm.
-
-
-
Thermometer Inlet Adapters with Top Tubulature
DWK Life Sciences (Kimble)Standard Taper joint at the bottom and a tubulature at the top Includes a rubber adapter with a ¼" hole in the top for use with plain stem thermometers, gas inlet tubes, etc. Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438,…
-
Adapter, Thermometer, 10/20
Ace GlassMade of PTFE with Nylon knurled nut to adapt standard chemical thermometers. For use in 10/18 or 10/30 joints. Simple to use: insert thermometer to desired depth, tighten nut.
-
Adapter, Thermometer, PTFE
Ace GlassPTFE adapter with FETFE O-Ring for use with plain stem thermometers, gas inlet tubes, etc. O-Ring compression seal allows adjustable depth positioning. 10/18 size will accommodate tubes up to 6.5mm, all other sizes up to 7mm. All sizes have one internal O-ring size -108. Except for 10/18 size, all…
-
Adapter, Thermometer, 10° Offset
ChemglassAdapter has a 10/30 outer joint at the top for use with CG-3506 thermometers. When used with vertical side neck flasks, thermometers can be angled into the bottom of the flask. FOR THERMOMETERS SEE CG-3506-N.
-
Adapters, Thermometer, Inlet
ChemglassAdapter has a tubulation at the top for use with a CG-1040 rubber fitting. Fitting permits insertion of plain stem thermometers or bleed tubes. Supplied complete with one CG-1040 rubber fitting.
-
Adapters, Thermometer, Inlet
ChemglassAdapter has a #7 or #15 Chem-Thread at the top for vacuum tight seal of plain stem thermo-meters or any other tube having an O.D. between 4 and 7mm. Supplied complete with a Celcon® compression cap and Viton o-ring.
-
SYNTHWARE Inlet/Thermometer Adapter
Kemtech AmericaThermometer Adapter, Microscale, Synthware, Joints: 14/10, Thermometer OD: 5.0-7.5mm, supplied with one compression cap and one Viton O-ring.
-
Adapters, Thermometer, Inlet, 10° Offset
ChemglassAdapter has a #7 Chem-Thread at the top for vacuum tight seal of plain stem thermometers or any other tube having an O.D. between 4 and 7mm. When used with vertical side neck flasks, thermometers or bleed tubes can be angled into the bottom of the flask. Supplied complete with a compression cap and…
-
Adapters, PTFE, Thermometer, Inlet
ChemglassMade entirely of PTFE, adapter has an inner joint of the listed size. The compression nut allows for vertical adjustment of thermometers or bleed tubes having an O.D. between 6 and 7mm. Supplied complete with one #108 Viton o-ring.
-
Adapter, with Thermometer joint, Offset
Ace GlassWith standard taper 10/30 thermometer joint for 76 mm immersion.
-
Synthware Inlet/Thermometer Adapters
Kemtech AmericaAdapter has a Nylon compression cap and a Viton o-ring to form a vacumm tight seal. Cap accommodates 5.0 - 7.5mm O.D. thermometer or gas inlet tube. To use it as a syringe port, simply replace the o-ring with a PTFE-lined septum. Supplied with one Nylon cap and one Viton o-ring.
-
Ace-Thred™ Thermometer/Tubing Adapters
MilliporeSigmaGeneral Description Threaded nylon bushing with FETFE® O-ring. Legal Information Ace-Thred is a trademark of Ace Glass, Inc.; FETFE is a registered trademark of Ace Glass, Inc.
-
Synthware Distillation Adapters with Threaded Thermometer Ports
Kemtech AmericaSynthware distillation adapter with threaded thermometer port. The threaded port will accommodate a 6-7.5mm O.D. plain thermometer. The adapter has standard taper top outer joint and inner joints for the bottom and side. All joints are the same size.
-
Includes one standard Radiello vertical adapter (RAD122) for each thermometer, configured for standard use, pk of 3
-
OptiChem® Heater Block Adapter
Chemglass…excellent heat transfer and does not interfere with magnetic field Thermowell is provided for insertion of a contact thermometer or PT100 sensorOptiChem® Heater Block adapter is designed to fit all hot plate stirrers with a 135mm diameter top plate. Lower edge of block covers side of top…
-
Poly-Cone Universal Joint Adapter
SP Bel-ArtThis precision-engineered adapter may be cut with a fine-tooth saw or sharp knife into various adapters, such as individual bushings, stirrer bearings, thermometer and gas inlet tube supports, drip-tips, funnels, trap connectors for tubing, etc. Forms a continuous standard taper inside and…
-
Safe-Lab® Therm-O-Vac® Port Adapter
SP Bel-ArtMade from PTFE with Viton® O-ring on the body, screw cap and hose connection. Threads into Adapt-A-Port® body for use in standard taper glassware. NOT autoclavable. Accepts thermometer or straight glass tubing. Includes side mounted vacuum port
-
…Contact Thermometer •Electronic contact thermometer with 3 operating modes •With optimized PID control •RESET function •Incl. stainless steel sensor H 62 •For all magnetic stirrers with contact thermometer bushing according to DIN 12878, class 2 e.g. IKA, Heidolph and Corning with adapter AD-C1…
-
Adapter Univ Sz 21 19/22
DWK Life Sciences (Kimble)For use with plain thermometers, pipets, syringes or other small items with an OD from 2 to 17 mm. A vacuum-tight seal is created with the open top compression cap and FKM o-ring to allow adjustable immersion of thermometers Cap is suitable for use to 150 °C To use it as a septum…
-
Adapter Univ Sz 21 29/42
DWK Life Sciences (Kimble)For use with plain thermometers, pipets, syringes or other small items with an OD from 2 to 17 mm. A vacuum-tight seal is created with the open top compression cap and FKM o-ring to allow adjustable immersion of thermometers Cap is suitable for use to 150 °C To use it as a septum…
-
Adapter Univ Sz 21 24/40
DWK Life Sciences (Kimble)For use with plain thermometers, pipets, syringes or other small items with an OD from 2 to 17 mm. A vacuum-tight seal is created with the open top compression cap and FKM o-ring to allow adjustable immersion of thermometers Cap is suitable for use to 150 °C To use it as a septum…
-
Flask, Two Necks, Pear-Shaped
Ace GlassPear-shaped, with side arm for use with 9095 rubber thermometer adapter. Joint is 14/20.
