  • …single bank vacuum manifold with 4 or 6 ports. Main tube is 1" OD with a serrated hose connection, having the smallest serration 13.5mm and the largest serration 15.5mm, located at either the left or right side for vacuum connection. Ports are 4mm PTFE stopcocks with serrated hose connections…

  • Similar to the CG-4440 vacuum manifold, but with BOTH ENDS OF INERT GAS LINE OPEN to permit connection to the gas source and an oil bubbler. Hose connections have a 10mm small serration and a 11mm large serration.

  • With 14/20 outer joint at the center to fit a rubber septum for keeping syringes under an inert environment cutting down on the number used.

  • stopcock allows the manifold to be vented to atmosphere when used under closed conditions without breaking the vacuum connection. The valve vent is female luer slip and accepts a disposable syringe filter(13JP020AN) or KS13 holder with PTFE filter(J020A013A) to maintain sterility. The main manifold

  • Advantec MFS

    …or 8b stopper to adapt to microanalysis units of various sizes. The 3-place manifold can accomodate 90mm holders. Use 47mm or smaller holders on the 6-place model. The 2-way valve is PVC with a PTFE stopcock. The manifold outlet is 1/4"male to hose barb fitting connects to 3/8" id tubing.…

  • Agilent Technologies

    manifolds and accessories complement the quality of AccuBOND II sorbents. Flexible configurations and availability as complete assemblies or individual components mean that the user has the necessary capability at any stage from method development to high throughput operation. Vacuum manifold

  • …adapt to various microanalysis units. The 3-place manifold can accomodate 90mm holders. Use 47mm or smaller holder units on the 6-place model. Valves have a PTFE stopcock. Available with 2-way or 3-way valves. Use the 3-way valve when the manifold is used under closed conditions and must be vented…

  • General purpose manifold with 2mm or 4mm Teflon® stopcocks. Main tube is 22mm O.D. with serrated hose connection (10mm O.D.). Delivery ports have 10mm serrated hose connections. Distance between stopcocks is 75mm.

  • Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • …port manifold with 2mm bore glass stopcocks on the ports. A "T"-bore stopcock is located 100mm from the end of the manifold and 40mm from the first port. The distance between the other 3 ports is 50mm with the last port being 75mm from the opposite end of the manifold. The entire manifold

  • Similar to CG-1814 but supplied with all PTFE stopcocks.

  • 1164V90-V91 Double Manifold, Hollow Glass Stopcocks, Spherical Joints, 4 and 5 port manifold available, Joint Size: 35/20, Connections front-left right and rear-right, Overall Width: 365 and 450mm available. 1164V92 Double Manifold, Hollow Glass Stopcocks, Spherical Joints, Ports: 4, Joint…

  • With 4mm double oblique, high vacuum solid glass stopcocks precision ground with corresponding numbers on barrel and plug. Solid glass stopcocks have constant pressure retention devices. Distance between stopcocks is 75mm center to center.

  • Ace Glass

    Hign vacuum manifold systems feature Easy Action PTFE stopcock valves providing for greaseless operation. Double-tube codes -50 & -54 feature Ace-Threds and 8mm OD tube-end ports. Double tube code -52 features hose barbed connections and 45 degree port placement. Walters manifold, code -40,…

  • Ace Glass

    For portable gas analysis apparatus. Three or four straight 2 mm bore glass stopcocks and one three-way stopcock with back port, fabricated on capillary tubing. We can fabricate special gas manifolds of all kinds.

  • SP Wilmad-LabGlass

    This borosilicate glass Air-Tite vacuum gas manifold (Schlenk line) is designed with double oblique pressure/vacuum stopcocks with 4mm bores and a 16.2/56 plug size. The stopcocks simplify evacuation or pressurization with an inert atmosphere. Manifold is 1" O.D.

  • …extraction manifold a great alternative to stainless steel. Polyvinylchloride(PVC) is resistant to acids. The tapered branch accepts a 40/35 female joint to adapt to microanalysis units. The valve is PVC with a PTFE stopcock. The 3-way PVC valve with PTFE stopcock allows the manifold to be vented…

  • MilliporeSigma

    …in the manifold body or, through use of a threaded drain port, diverted to any auxiliary reservoir providing virtually unlimited capacity. The manifold includes chemically resistant Endura-Luer stopcocks that will not crack or break with repeated use. Application: VM20 Vacuum Manifold has been…

  • manifold by itself. Can be joined to ACE 8737,8738 or 8739 manifolds or as a stand alone manifold. The code -23 consists of the -03 manifold and our 8753-21 tube, making a trap unit. It has a 15mm o-ring joint with a 0-10mm PTFE stopcock on one end and a #15 Ace-Thred with a 0-10mm PTFE stopcock on…

  • …taper branch accepts a 40/35 female joint to adapt to various microanalysis units. Valves have a PTFE stopcock. Available with 2-way or 3-way valves. Use the 3-way valve when the manifold is used under closed conditions and must be vented to the atmosphere without breaking the vacuum connection.…

  • Thermo Scientific Nalgene

    …securely holds a No. 8 stopper and the stem filter funnel without interference Autoclavable Easy manipulation of individual funnels due to spacing of outlets. Teflon stopcock on each valve shuts off flow when fewer than three outlets are used. Barbed fitting accepts 3/8” i.d. tubing.

  • DWK Life Sciences (Kimble)

    An all-glass manifold for connecting inert gas and vacuum sources. Double vacuum gas manifold with vacuum chambers. Fabricated from 1/2" medium wall tubing Stopcocks are 4 mm bore glass with lower vacuum chamber and are spaced 85 mm apart Top right connection is for inert gas and…

  • With 4mm double hollow high vacuum stopcocks. This four–port manifold is fitted with two 14/20 and 24/40 inner joints, and is 100mm center to center joints.#15 O-ring joint stopper (S480015) and #15 O-ring joint to serrated hose adapter have to be ordered separately. Viton® O-rings can be…

  • …glass addition funnel. Has either a 2mm glass stopcock or a 0-3mm inlet valve side arm. Has an outer standard taper joint top. Funnel has a 0-4mm Hi-Vac valve bottom outlet ending in an inner standard taper joint. Ideal for Schlenk lines or using to connect or add on to vacuum and NO-AIR manifolds.

  • …material. Top has inner standard taper joint. Funnel has side arm with 2mm glass stopcock. Bottom outlet has a 0-4mm Hi-Vac valve for precise control and ends in an inner standard taper joint. Both upper and lower joints are the same size. Ideal for adding to NO-AIR and vacuum lines and manifolds.

  • quick-ship

    Cadence Science

    Cadence Science® stopcocks are precision-machined, individually lapped, and carefully mated to maintain pressure characteristics. These stopcocks are easily integrated with other stopcocks, manifolds, adapters, tubing, needles, and glass syringes. Made from nickel plated brass or…

  • Cadence Science

    Cadence Science® stopcocks are precision-machined, individually lapped, and carefully mated to maintain pressure characteristics. These stopcocks are easily integrated with other stopcocks, manifolds, adapters, tubing, needles, and glass syringes. Made from nickel plated brass or…

  • General purpose double bank vacuum manifold with 3, 4, or 5 ports for use with vacuum and inert gas. Both tubes are 1/2” OD with serrated hose connections located on the upper left and lower right banks. Ports are 4mm high vacuum stopcocks with serrated hose connections. Ports are spaced 85mm…

  • …individually using the optional PTFE stopcocks Separate waste container prevents tank contamination Use vacuum manifolds for SPE sample preparation, filtration, and elution. Manifolds come complete with everything you need—tank, lid, needles, stopcocks, rack, vacuum gauge, waste…

  • Stopcocks are rugged, reusable and provide independent flow control to meter the sample as it is pulled through the vacuum.

  • Cover Gasket to house the stopcocks are available for purchase with either 12 or 24 stopcocks options.