  • A-332 Semi-Prep Stainless Steel Frit

    IDEX Health & Science

    Our Semi-Prep Stainless Steel Frit is the most common size frits used throughout HPLC systems. We design these frits to deliver excellent uniform porosity and a long filtration life. It has a porosity of 2µm and comes with a natural color Tefzel® (ETFE) ring.

  • …316 stainless steel, and we offer sizes to fit most column and pore sizes. To choose the correct frit, check its pore size compatibility with the particle size of the packing in the column. If the packing has a smaller particle size than the pore size of the frit, the packing can clog the frit.

  • …improper installation Easily refillable Tested to 150 psi (helium) Both inlet and outlet connectors are equipped with stainless steel frits to prevent particulates from entering the gas stream. Indicating 4Å is the preferred adsorbent for GC gas drying. Blue indicating…

  • …clamp, fritted glass support base and filtration flask. Joints are Standard Taper 40/35. Recommended when filtering viscous or proteinaceous solutions to give the maximum flow rate Produces an ultra-clean filtrate Two filter sizes available: 47 or 90 mm Stainless steel screen…

  • Solvent Inlet Filters

    Thermo Scientific

    For HPLC Systems Stainless steel 10µm inlet filters for longer lifetime No tools required for replacement Bottom-of-the-Bottle solvent filters: Efficient draw 100% PTFE polymer, including 2µm filter Built-in helium sparge port and frit

  • …The anodized aluminum clamp secures the membrane between the funnel and glass base. While the sintered glass frit support base can be used for general filtration, the 304 stainless steel screen(w/ PTFE gasket) is recommended for viscous or proteinaceous solutions to maximize flow rate and the screen…

  • …The anodized aluminum clamp secures the membrane between the funnel and glass base. While the sintered glass frit support base can be used for general filtration, the 304 stainless steel screen is recommended for viscous or proteinaceous solutions to maximize flow rate and the screen ensures…

  • In-line design installs easily with standard fittings Cost-effective protection for UHPLC systems Reliable way to extend column lifetime Leak-tight to 15,000 psi (1,034 bar) Replaceable 0.5 µm stainless steel frit in stainless steel body

  • Big Oxygen Traps

    Agilent Technologies

    …gas purifiers Ideal for bulk purification applications or where several instruments are plumbed from a single gas source One piece of heavy-walled aluminum tube. This one-piece design eliminates potential leaks Equipped with sintered stainless steel frits to prevent particulate contamination

  • …membrane. The anodized aluminum clamp secures the membrane between the funnel and base. While the sintered glass frit support base can be used for general filtration, the 304 stainless steel screen(w/ PTFE gasket) is recommended for viscous or proteinaceous solutions to maximize flow rate and the…

  • …The anodized aluminum clamp secures the 25mm membrane between the funnel and base. While the sintered glass frit support base can be used for general filtration, the 304 stainless steel screen(w/ PTFE gasket) is recommended for viscous or proteinaceous solutions to maximize flow rate and the screen…

  • Tall form gas washing bottle having a standard taper 34/28 top joint, hex base and coarse fritted tube for gas dispersion. Stopper is held in place with two CG-110-02, 18mm stainless steel springs. Springs are supplied when bottle is ordered complete.

  • …with stainless steel support is recommended when filtering viscous or proteinaceous solutions to give the maximum flow rate. This apparatus is also used to produce ultra clean filtrate since the stainless steel screen will not shed particles into the filtrate. Like the apparatus with fritted glass…

  • …The anodized aluminum clamp secures the membrane between the funnel and glass base. While the sintered glass frit support base can be used for general filtration, the 304 stainless steel screen is recommended for viscous or proteinaceous solutions to maximize flow rate and the screen ensures…

  • …aluminum clamp secures the 47mm membrane between the 300mL graduated funnel and base. While the sintered glass frit support base can be used for general filtration, the 304 stainless steel screen(w/ PTFE gasket) is recommended for viscous or proteinaceous solutions to maximize flow rate and the…

  • …Mechanism: Normal phase or Adsorption Sample Matrix Compatibility: Organic solutions Mesh: 100/200; Available with PTFE or stainless steel frits Tested for US Environmental Protection Agency (EPA) Contract Laboratory Program (CLP) statement of work for pesticides Highly polar…

  • …porosity fritted disc sealed into the lower end of the column for packing support. Column is constructed using MEDIUM WALL tubing. Can be used with CG-1201 flow controller. Connection between the column and flow control adapter are spherical joints connected with CG-150 stainless steel clamps.

  • …is constructed using MEDIUM WALL tubing. Can be used with optional CG-1201 flow controller and CG-1200 reservoir. Lower end of the column has a round bottom. Connections between the column, reservoir and flow control adapter are spherical joints connected with CG-150 stainless steel pinchclamps.

  • Big Hydrocarbon Traps

    Agilent Technologies

    …for bulk purification applications or where several instruments are plumbed from a single gas source One piece of heavy-walled aluminum tube. This one-piece design eliminates potential leaks. Equipped with sintered stainless steel frits to prevent particulate contamination Refillable

  • …port plugs 1, Syringe ports 1, PEEK finger-tight body 2 µm stainless steel frit filter Instructions 1170C59: Inline Filter Kit Kit includes five PEEK finger-tight body 2 µm stainless steel frit filters to protect the picoSpin capillary cartridge from particulates. …

  • Sampling Screen

    PerkinElmer

    …hydrocarbon impurities (50 ppm or less) from inert gases, nitrogen and hydrogen at room temperature to low ppb range, Capacity of 67 g of hydrocarbons C5 and heavier, 10 µ stainless steel porous frits protect gas stream from particulates, and Individually helium leak tested. Shipped lled wth helium.

  • …GC gases. Available in three refillable sizes and three different packings Both inlet and outlet connectors are equipped with stainless steel frits to prevent particulates from entering the gas stream Mixed packing bed makes improper installation impossible Easily refillable …

  • …µm frit filter, vacuum gauge, and sample inlet. The gauge and sample inlet are downsized for use with smaller canisters. Provide accurate integrated sampling without a sampling pump Convenient smaller size connects easily to miniature canisters Available in stainless steel or with…

  • Filtration Assemblies & Flask

    DWK Life Sciences (Kimble)

    …a coarse fritted glass support base, 15 mL graduated funnel, anodized aluminum clamp and a #5 silicone stopper. Stainless Steel Support, 25 mm (4588A03) Used for filtering viscous or proteinaceous solutions or to produce ultra-clean filtrate. Supplied with a 316 stainless steel support…

  • 316 stainless steel tubing complete with end-fittings, frits, nuts, and ferrules Preassembled prior to shipment Internal 1/16" seats are compatible with Valco and Parker fittings

  • This 316 stainless steel filter is designed to collect particles larger than 7 microns. We offer Siltek-treated and stainless steel versions (1/4" compression fitting on both ends). Note: frit is not replaceable.

  • In-line Solvent Filters

    IDEX Health & Science

    In-line Solvent Filters for running cleaner systems Help prevent particulates from clogging equipment Parts made of stainless steel and PEEK® Replacement frits available

  • Big Universal Traps

    Agilent Technologies

    …CO2, CO and hydrocarbons at a flow rate of up to 8 liters/minute. All tube fittings are Swagelok brand stainless steel, fitted with 40 micron stainless steel frits for particulate control. Maximum pressure is 500 psi. Big Universal Traps are more economical than other purifiers.…

  • A-331 Stainless Steel Frit

    IDEX Health & Science

  • Hydrocarbon Trap

    PerkinElmer

    …hydrocarbon impurities (50ppm or less) from inert gases, nitrogen and hydrogen at room temperature to low ppb range.Capacity at 67 g. of hydrocarbons C5 and heavier.10u stainless steel porous frits protect gas stream from particulates.Individually helium leak tested. Shipped filled with helium.

  • …and flexibility. The filter has a replaceable, PEEK encapsulated 316 stainless steel frit with a surface area of 12 mm 2 . The standard frit with 2.0 µm porosity may be replaced with an optional 0.5 µm porosity frit. Use of this filter can greatly extend column life, thereby reducing…

  • Cost-effective protection for UHPLC systems Reliable way to extend column lifetime Universal fit—connects easily to any brand column Leak-tight to 15,000 psi (1,034 bar) 0.5 µm or 0.2 µm titanium frit in a stainless steel body with PEEK ferrule