Size Exclusion Column
-
G-Sep™ Size Exclusion Columns
G-Biosciences…kDa to 600 kDa. G-Sep™ Size Exclusion Columns, 3-70 kDa have performace similar to Superdex™ 75 pg columns andG-Sep™ Size Exclusion Columns, 6-600kDa haveperformance similar to Superdex™ 200pg columns. G-Sep™ Size Exclusion Columns comes in two format the classic one…
-
TSKgel® UP-SW3000 HPLC Column
MilliporeSigma…of Tosoh Corporation Other Notes: Related Catagories: Analytical/Chromatography, HPLC, HPLC & FPLC Columns for Biopolymer Separations, TSKgel Gel Filtration Columns for Proteins and Other Biopolymers, TSKgel Gel Filtration Columns to Analyze Purity and Aggregates, TSKgel Size Exclusion Columns
-
TSKgel® UP-SW3000 HPLC Column
MilliporeSigma…of Tosoh Corporation Other Notes: Related Catagories: Analytical/Chromatography, HPLC, HPLC & FPLC Columns for Biopolymer Separations, TSKgel Gel Filtration Columns for Proteins and Other Biopolymers, TSKgel Gel Filtration Columns to Analyze Purity and Aggregates, TSKgel Size Exclusion Columns
-
Protein Purification Columns
G-BiosciencesPrepacked purification columns for purification are available in packs of 5.The columns available are the anionic chromatography columns, hydrophobic columns, size exclusion (gel filtration) columns.
-
Synonym: TSKgel® Size Exclusion (SW-Type) HPLC Guard Column General Description Guard Column for 7.5mmID TSKgel G2000SW, G3000SW and G4000SW columns TSKgel Guard Columns are stand-alone and do not require separate holders. Physical Form Shipped in 0.05% NaN3 and 0.1 mol/L…
-
…TSKgel® Size Exclusion (SW-Type) HPLC Column Physical form 20S isomer General description As the first generation of silica-based SEC columns, TSKgel G2000SW provides excellent separation of peptides and proteins with molecular weights up to 100,000 Da.TSKgel G2000SW columns…
-
TSKgel® UltraSW Aggregate HPLC Column phase diol
MilliporeSigma…using many different modes of HPLC, size exclusion is best for aggregation, dimer, and fragmentation, making it the best method for heterogeneity studies.TSKgel UltraSW Aggregate columns have a slightly larger pore size and smaller (3 mum) particle size than the industry-leading TSKgel G3000SWxl…
-
TSKgel® SuperSW2000 HPLC Column phase diol
MilliporeSigma…efficiency of 4mum columns, and because the column diameter of TSKgel SuperSW columns is 4.6mm, it is important to minimize the amount of dead volume in the HPLC system. Please call tech service if you need assistance. Synonyms: TSKgel® Size Exclusion (SW-Type) HPLC Column Legal Information:…
-
TSKgel® SuperSW3000 HPLC Column phase diol
MilliporeSigma…benefit from the high efficiency of 4mum columns, and because the column diameter of TSKgel SuperSW columns is 4.6mm or less, it is important to minimize the amount of dead volume in the HPLC system. Synonyms: TSKgel® Size Exclusion (SW-Type) HPLC Column Legal Information: TSKgel is a…
-
HC-40 Cation Exchange Columns
Hamilton…size exclusion. HC-40 columns separate compounds through size exclusion. The 4% cross-linked HC-40 uses size exclusion as the primary mechanism of separation. The higher carbohydrate oligomers elute first while the smaller di- and monosaccharaides elute later. Pack Your Own Columns -…
-
ZORBAX Gf-250 and Gf-450gel Filtration Columns
Agilent Technologies…GF-250 and GF-450 size exclusion (gel filtration) columns are ideal for the size separations of proteins and other biomolecules. The separation range is 4,000-900,000 for globular proteins when using GF-250 and GF-450 columns in series. The GF-250/GF-450 size exclusion columns have a hydrophilic…
-
ZORBAX PSM GPC-Sec Columns
Agilent TechnologiesAgilent ZORBAX PSM Size Exclusion Columns can be used for molecular size separations on most synthetic and natural polymers. The ZORBAX PSM columns are packed with small (5 µm) porous silica microspheres (PSM) and are available in two versions. The deactivated version has been silanized for…
-
NUCLEOGEL® GPC HPLC Columns
MACHEREY-NAGEL…stability Matrix show nearly no shrinking when changing from polar to nonpolar solvents Eluent in column toluene Recommended application for exclusion chromatography (gel permeation chromatography, GPC) / size exclusion chromatography (SEC) of many water-insoluble substances.
-
Bio SEC-3 HPLC Columns
Agilent Technologies…under controlled conditions, ensuring a highly efficient size exclusion particle. Agilent Bio SEC-3 HPLC columns are available in 100 Angstrom, 150 Angstrom and 300 Angstrom pore sizes to accommodate most peptide and protein size exclusion separations. Features: Exceptional loading capacity,…
-
G-Trap™ GT-100 Desalting Columns
G-Biosciences…Column resin and the column are listed below G-Trap™ GT-100 Desalting Column resin Bead size: 55-165 µm Void volume: ~0.3 ml for 1 ml column and ~1.5 ml for 5 ml column Sample Load volume: 0.03 ml- 0.3 ml for 1 ml column and 0.75-1.5 ml for 5 ml column Exclusion…
-
SEC/GPC Columns
Separation Methods Technologies…mixtures. These columns are available in spherical 5 and 10 um particle sizes. Spherical 5 Åm silica particles provide a minimum of 20,000 plates per 30 cm x 7.8 mm I.D. column. Four pore sizes are available, ranging from an exclusion limit of about 2,000 Daltons for 300RP columns to more than…
-
G-Trap™ GT-1200 Desalting Columns
G-Biosciences…and the column are listed below G-Trap™ GT-1200 Desalting Column resin Bead size : 35-200 µm Void volume : ~0.3 ml for 1 ml column and ~1.5 ml for 5 ml column Sample Load volume: 0.03 ml- 0.3 ml for 1 ml column and 0.75-1.5 ml for 5 ml column Exclusion limit (Mr)…
-
G-Trap™ GT-600 Desalting Columns
G-Biosciences…Column resin and the column are listed below G-Trap™ GT-600 Desalting Column resin Bead size :20-130µm Void volume : ~0.3 ml for 1 ml column and ~1.5 ml for 5 ml column Sample Load volume : 0.03 ml- 0.3 ml for 1 ml column and 0.75-1.5 ml for 5 ml column Exclusion…
-
ZORBAX GF-450, 15.8 x 10 mm, guard cartridge (PrepHT), 5 um, 2/pk
Agilent Technologies…µm, 2/pk (use with end-fitting 820444-901, or standalone hardware kit 420420-901). Agilent ZORBAX GF-250 and GF-450 size exclusion (gel filtration) columns are ideal for size separations of Agilent Technologies products are intended for sale/shipment within the US only. International…
-
ZORBAX Diol, 4.6 x 12.5 mm, 6 um, guard cartridge (ZGC), 4/pk
Agilent Technologies…x 12.5 mm, 6 µm, guard cartridge (ZGC), 4/pk (use with hardware kit 820999-901). Agilent ZORBAX GF-250 and GF-450 size exclusion (gel filtration) columns are ideal for size separations of proteins and other biomolecules. Agilent Technologies products are intended for sale/shipment within…
-
Acclaim™ SEC-300 LC Columns
Thermo Scientific…Acclaim™ SEC-300 LC Columns. These resin-based, high-performance, size-exclusion chromatography columns cover molecular weight range: 5μm, 300Å. The combination of a proprietary mono-dispersed multi-pore hydrophilic resin and small particle size provides high-resolution and…
-
NUCLEOSIL® PPN HPLC Columns
MACHEREY-NAGEL…peptides and proteins up to about 40 kD, also suited for basic peptides Particle size 5 µm Pore size 100 Å pH working range 1–9 Max. working pressure 250 bar Eluent in column methanol NUCLEOSIL® 500-5 C18 PPN: octadecyl phase · USP L1 Dynamic protein…
-
Superose® 6 Increase 10/300 GL Cytiva, 29-0915-96, 10/300 GL
MilliporeSigmaSuperose® 6 Increase 10/300 GL is a versatile, prepacked column for high-resolution size exclusion chromatography in small-scale ( Synonyms: Superose® 6 Increase Legal Information: Superose is a registered trademark of Cytiva
-
NUCLEOGEL® SUGAR 810 HPLC Columns
MACHEREY-NAGEL…forms Due to a different selectivity pattern compared to NUCLEOGEL® SUGAR columns, the range of application is considerably enlarged Separation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatography H+ form: Separation…
-
G-Trap™ Ni IDA Agarose Fast Flow Columns
G-Biosciences…column respectively Exclusion limit(globular proteins) : 4 x 106 Chemical Stability : Stable to all commonly used aqueous buffers: 8 M urea, 6 M guanidine hydrochloride Storage Conditions : 2 to 8°C, 20% Ethanol G-Trap™ Ni IDA Agarose Fast Flow?, 1 ml columns Column…
-
G-Trap™ Octyl Agarose 6 Fast Flow Columns
G-Biosciences…for appropriate hydrophobic column and purification conditions for the target protein The properties of G-Trap™ Octyl Agarose 6 Fast Flow resin and column are listed below G-Trap™ Octyl Agarose 6 Fast Flow Resin Mean particle size : 90 µm Bead structure…
-
G-Trap™ Phenyl Agarose 6 Fast Flow Columns
G-Biosciences…appropriate hydrophobic column and purification conditions for the target protein The properties of G-Trap™ Phenyl Agarose 6 Fast Flow (High Sub) resin and column are listed below G-Trap™ Phenyl Agarose 6 Fast Flow (High Sub) Resin Mean particle size : 90 µm …
-
G-Trap™ Butyl Agarose 6 Fast Flow Columns
G-Biosciences…screening for appropriate hydrophobic column and purification conditions for the target protein The properties ofG-Trap™ Butyl Agarose 6 Fast Flow resin and column are listed below G-Trap™ Butyl Agarose 6 Fast Flow Resin Mean particle size: 90 µm Bead structure:…
-
G-Trap™ Co IDA Agarose Fast Flow Columns
G-Biosciences…ml column respectively Exclusion limit(globular proteins): 4 x 10 6 Chemical Stability: Stable to all commonly used aqueous buffers: 8 M urea, 6 M guanidine hydrochloride Storage Conditions: 2 to 8°C, 20% Ethanol G-Trap™ Co IDA Agarose Fast Flow?, 1 ml columns Column…
-
G-Trap™ Q Agarose Fast Flow Columns
G-Biosciences… Exclusion limit(globular proteins) : 4 x 10 6 Chemical Stability : Stable to all commonly used aqueous buffers:1 M NaOH, 8M urea, 8M guanidine hydrochloride, 70% ethanol Storage Conditions : 4 to 30°C, 20% Ethanol G-Trap™ Q Agarose Fast Flow?, 1 ml columns Column…
-
G-Trap™ CM Agarose Fast Flow Columns
G-Biosciences… Exclusion limit(globular proteins): 4 x 10 6 Chemical Stability: Stable to all commonly used aqueous buffers:1 M NaOH, 8M urea, 8M guanidine hydrochloride, 70% ethanol Storage Conditions: 4 to 30°C, 20% Ethanol G-Trap™ CM Agarose Fast Flow?, 1 ml columns Column Volume…
-
G-Trap™ DEAE Agarose Fast Flow Columns
G-Biosciences… Exclusion limit(globular proteins): 4 x 106 Chemical Stability : Stable to all commonly used aqueous buffers:1 M NaOH, 8M urea, 8M guanidine hydrochloride, 70% ethanol Storage Conditions: 4 to 30°C, 20% Ethanol G-Trap™ DEAE Agarose Fast Flow ?, 1 ml columns Column…