Short Path Distillation

Compare Tool

Select up to 3 products

Short Path Distillation
1 - 23 of 23
Sort
View
Show
  • Short Path Distillation Head

    United Scientific Supplies

    Short Path Distillation Head with 24/40 flask joints and 10/30 thermometer port. Distillation head is manufactured from high quality 3.3 borosilicate glass and features a condenser coil and three 1/4" hose nozzles, two for condenser and one for vacuum.

  • Short Path Distillation Kit

    United Scientific Supplies

    …cap the 2000ml Single Neck round bottom flasks after distillate is collected. PLEASE NOTE: Lab Jacks, Support Stands, Flask Stands, and Extension Clamps with Bosshead are not included in this kit. Contents: Short Path Distillation Head, Vacuum Jacketed, 24/40, 34/45 . . . . . . . .…

  • Short Path Distillation Kit

    United Scientific Supplies

    This kit contains essential components for short path distillation. All glass parts are manufactured from high quality 3.3 borosilicate glass. Short Path Distillation Head with 24/40 flask joints and 10/30 thermometer port features a condenser coil and three ¼” hose nozzles, two for…

  • Short Path Distillation Sleeve

    Ai insulating sleeves for distillation heads will keep your distillation setup at the peak of its performance. A right-facing observation window allows you to see exactly what is happening inside your glassware. A left-facing observation window allows you to see exactly what is happening inside your…

  • SYNTHWARE Short Path Distilling Head with 24/40 Joint

    Kemtech America

    One-piece design for easy set-up. For the best result, use D272440 distillation receiver. To be used with 25mm immersion thermometer.

  • SYNTHWARE Short Path Distilling Head for Volatile Solvents

    Kemtech America

    With the condenser being a combination of a cold coil and Leibig. Top outer joint is a 10/18 for use with a 50mm immersion thermometer. For best result, use D272440.

  • Distillation Apparatus, Short Path

    Ace Glass

    Designed for small quantities where holdup between flask and receiver must be minimized but where it is also desired to measure vapor temperature with an accuracy compared to large setups. Improved thermometer sensitivity. Physical carry-over is practi

  • Distillation Apparatus, Short Path

    Ace Glass

    Designed for small quantities where holdup between flask and receiver must be minimized, but where it is also desired to measure vapor temperature with the accuracy of larger setups. Still body is available with or without vacuum jacket and with vigreu

  • Distilling Head, Short Path

    Chemglass

    Designed for use with small quantities where hold up between the flask and receiver must be kept to a minimum. The thermometer bulb and stem serve as column packing. Upper hose connections are for cooling lines while the lower connection is for vacuum. Available with Vigreux indentations to improve…

  • SYNTHWARE Short Path Vacuum Jacketed Distillation Apparatus

    Kemtech America

    …design for more efficiency. When a thermometer is inserted in the top of this apparatus, the bulb and stem serve as column packing. The close coupled condenser and vacuum connection offer and extremely short condensate travel path. Used with 25mm immersion thermometer, and D27 distillation receiver.

  • SYNTHWARE Short Path Vaccum Jacketed Distillation Apparatus

    Kemtech America

    Used with 25mm immersion thermometer, and D27 distillation receiver.

  • Heavy Wall Short Path Vacuum Jacketed Distillation Heads

    Across International

    The Ai heavy wall short path distillation head with vacuum jacket. Features Heavy wall for durability Boiling flask and distribution ports Vacuum jacketed Five sets of vigreux Thermo probe port: 14/20 joints Recirculating fluid ports: GL-16 adapters Glass material:…

  • Distilling Head, Short Path, Improved

    Chemglass

    …connection “A” through the coil and exits the outer jacket through hose connection “B”. Head is excellent for use when distilling medium to high boiling point solvents. Top outer joint is a 10/30 for use with a 2” immersion thermometer. Available with or without Vigreux…

  • Distilling Head, Short Path, Jacketed

    Chemglass

    Similar to CG-1239 but vacuum jacketed to improve efficiency. Available with Vigreux indentations in uptake tube to further increase the performance of the head. NOTE: The 14/20 size accepts a 1” immersion 7/12 or 10/18 thermometer, while the 24/40 and 29/42 sizes accept a 2”…

  • Still Head, Short Path

    Ace Glass

    Jacketed distillation head for distilling samples up to 3mL Jacket allows positioning of a coolant such as dry ice/acetone at site of desired condensation, thus reducing loss of valuable sample.Distillate can be removed with a Pasteur pipet. With outer 14/20 joint at top and 14/20 inner at…

  • SYNTHWARE Microscale Distillation Apparatus

    Kemtech America

    Short-path design for microscale application, used with 25mm immersion thermometer, and D27 distillation receiver.

  • SYNTHWARE Distillation Receivers

    Kemtech America

    With the outer and inner joint at 135° angle, used with short-path.

  • Still II, Short Path, Firestone with Jacket

    Ace Glass

    Zero holdup, no-splash short path still for small quantity distillations with the accuracy of larger setups. Improved design eliminates even the minimal holdup experienced with original short path stills by further reducing wetted surfaces and travel p

  • Still, Short Path, with 24/40 Joints

    Ace Glass

    Full size 24/40 jointed, low holdup, short path still, original plain version or jacketed with indents. Extension tube from still body allows positioning of drop directly over receiver flask. Gas inlet tube is positioned in distillation flask with 5028 Adapter and secured with a #7 Ace-Thred.…

  • Distilling Receiver, 14/20, Complete

    Chemglass

    The 135° angle between the center line of the condenser and the receiver tubes allows the distillate to fall directly into the receiver tubes. This receiver can be used with short path style distilling heads. Complete receiver is supplied with distribution adapter, three 12mL receiver tubes, and…

  • Still, Short Path, Minimum Hold-Up, 10/18 Pot Joint

    Ace Glass

    Supplied as shown with one-piece receiver. 9316-04 cow receiver with 9477-02, 5mL flasks may be used in place of one-piece receiver. Gas inlet tube is positioned in distillation flask with a 5028-24 threaded adapter. Forner 7/12 thermometer joint has b

  • SYNTHWARE Shortpath Distilling Head for Volatile Distillants

    Kemtech America

    With the condenser being a combination of a cold coil and Leibig. Top outer joint is a 10/18 for use with a 50mm immersion thermometer. With Vigreux Indentations.

  • Ai HeatedShield 400°C Rated Fabric Heating Tops for Flasks

    Across International

    The Ai ultra-thick 400°C HeatedShield flask cover will keep your distillation setup at the peak of its performance. Prevents vapor condensation in the upper half of a flask and protects the flask and its contents from drafts, which would distrub the reflux ration during fractionation. It…

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.