  • The deflected needle style features point positioning on the axis of the needle lumen. This improved point geometry provides easier penetration and minimizes coring and tracking (particularly with finer gauge needles).

  • General-purpose point style designed for septum penetration in all chromatographic techniques. The needle has a 22 bevel with the tip slightly bent to minimize coring and needle plugging.

  • …Removable needles are made for use with removable needle (RN) syringes and will not work with any other hub. Point Style 2 is a 22° beveled tip point recommended for septum penetration. The tip is slightly bent, partially obstructing the orifice and minimizing septum coring and needle

  • 11mm Snap Top Caps™

    J.G. Finneran

    …using the magnets found on these instruments. Thomas no.: 1167F43 The 11mm Snap Cap with an integral molded polyethylene septum area is now available pre-slit in order to offer a penetration aid for dull or thick needles. The closure is easy to snap on and easy to remove with just a finger.

  • RELI® Blunt Fill Needle

    MYCO Medical Supplies

    …1.5” Needle aids penetration of different septum barriers Eliminates the use of a sharp, reducing the risk of a needle-stick injury Compatible with most syringes available in the market Sterile, Single use, PVC free, Not made with natural rubber latex RELI® Blunt Fill Needles are…

  • Needle guide allows easy penetration and prevents septum coring Manual injection septum nut allows use of 26-gauge needles for on-column injections Made of high-quality stainless steel

  • …quick change of needle and use of different gauge and/or style needles with the same barrel. Point Style 2 tips have a 22° beveled point recommended for septum penetration. The tip is slightly bent, partially obstructing the orifice, minimizing septum coring and needle plugging. Point…

  • General-purpose point style designed for septum penetration in all chromatographic techniques. The needle has a 22 bevel with the tip slightly bent to minimize coring and needle plugging.

  • General-purpose point style designed for septum penetration in all chromatographic techniques. The needle has a 22 bevel with the tip slightly bent to minimize coring and needle plugging.

  • …repeatable injection depths. Point style 2 needles are beveled, non-coring needle points for septum penetration. Point style 3 needles are recommended for HPLC injection valves and for sample pipetting. Repair kits for knurled hub (KH) syringes containing needle, ferrule and plunger are available on…

  • Thermogreen ® Injector Septa, extremely low bleed over a wide range of inlet temperatures -100 to 350 °C. Easier needle penetration and high puncture tolerance make this septum ideal for autosamplers. This septum is already conditioned and ready to use.

  • …joint and lower inner joint of the same size. Addition of the outer joint permits use of the larger sizes of the CG-3022 septum stoppers for repeated needle penetrations. Adapter also allows for evacuation and transfer of product into another vessel with the same size standard taper joints.…

  • Target DP* 9 mm Convenience Kit

    National Scientific

    …AVCS technology, the C5000 series wide opening closure increases the available injection area by over 7% providing greater area for injection needle penetration. National C5000 Series Target DP 9mm Integral Membrane Closure In addition to AVCS technology, the C5000 series closure provides a…

  • Septa

    Agilent Technologies

    …Center point guides the needle for easy penetration and less coring. Long-Life Septa are the preferred septum for autosamplers and are ideal for overnight runs. You can make up to 400 injections per septum and its soft 45 Durometer rating is easy on autosampler needles. Advanced green…

  • Marathon Septa

    Chromatography Research Supplies

    …Very low bleed Maximum temperature of 350°C Septum typically achieves 400 injections without failure when used with HP-style needles and autosampler needle guide. Soft, 45 Durometer, septa are easy on autosampler needles. Also ideal for standard manual-injection GC and GC/MS. Selected…

  • …injection life septum typically achieves 400 injections without failure, when used with a rounded-tip (Agilent-style) needle and autosampler or needle guide. Ideal for standard manual-injection GC and GC/MS. 3 mm thick. CenterGuide™ design requires less force for initial penetration, for a…

  • …– also been tested analytically Red Rubber / FEP septum for routine analyses; for more demanding analyses: high purity silicone / PTFE septa Slit silicone/PTFE septa as a penetration aid for thick / blunt HPLC needles Packed with 100 pieces in a resealable, tamper-evident zip-lock…

  • Screw closures/caps, N 10

    MACHEREY-NAGEL

    …with a broad variety of septa materials Red Rubber / FEP septum for routine analyses; for more demanding analyses: high purity silicone / PTFE septa Slit silicone/PTFE septa as a penetration aid for thick / blunt HPLC needles Packed with 100 pieces in a resealable zip-lock bag Closures…

  • …– also been tested analytically Red Rubber / FEP septum for routine analyses; for more demanding analyses: high purity silicone / PTFE septa Slit silicone/PTFE septa as a penetration aid for thick / blunt HPLC needles Packed with 100 pieces in a resealable, tamper-evident zip-lock…

  • …– also been tested analytically Red Rubber / FEP septum for routine analyses; for more demanding analyses: high purity silicone / PTFE septa Slit silicone/PTFE septa as a penetration aid for thick / blunt HPLC needles Packed with 100 pieces in a resealable, tamper-evident zip-lock…

  • …assembly. Three-layer septum natural rubber / butyl / TEF or two-layer septum Red Rubber / FEP for routine analyses; for more demanding analyses: high purity silicone / PTFE septa Cross-slit silicone/PTFE septa as a penetration aid for thick / blunt HPLC needles For all autosamplers…

  • …premium GC septa to the highest-temperature applications. 3 mm thick. CenterGuide™ design requires less force for initial penetration, for a smoother feel. Septum life may be enhanced in some applications by minimizing tearing and coring. Low Bleed High Temperature Septa for operating…

  • …– also been tested analytically Red Rubber / FEP septum for routine analyses; for more demanding analyses: high purity silicone / PTFE septa Cross-slit silicone/PTFE septa as a penetration aid for thick / blunt HPLC needles Snap ring vials may alternatively also be crimped with 11…

  • …technology, the C5000 series wide opening closure increases the available injection area by over 7% providing greater area for injection needle penetration. National C5000 Series Target DP 9mm Integral Membrane Closure In addition to AVCS technology, the C5000 series closure provides a …

  • Target DP 9mm Vial Closures

    National Scientific

    …technology, the C5000 series wide opening closure increases the available injection area by over 7% providing greater area for injection needle penetration. National C5000 Series Target DP 9mm Integral Membrane Closure In addition to AVCS technology, the C5000 series closure provides a halogen…

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.