Sealing Paddle

Compare Tool

Select up to 3 products

Sealing Paddle
1 - 32 of 35
Sort
View
Show
  • …Length between the perforations wth end tabs removed is 118.1 mm. Each package of ThermalSeal® A™ films includes one sealing paddle for ensuring a firm seal, also compatible with raised-rim plates. Heat resistant, recommended for temperatures from -40°C to +120°C Can…

  • quick-ship

    Excel Scientific

    Paddle and Plate Roller Secures uniform plate seal for each well Roller is compatible with all flat-top multi-well plates Paddle is compatible with both raised-rim and flat-top multi-well plates Film-Sealing Paddles Alternative to plate roller for pressing sealing film to…

  • …product. Hycheck paddles are available in 7 media combinations, and the hinged paddle provides greater sampling flexibility. Paddles require no rehydration of the swab, no inoculating into the buffer and no transfer of buffer to plates. The economical Hycheck paddle replaces 2 swabs, 2…

  • PTFE, large-scale, multi-paddle agitator design to accept pinned bottom valves, like our 6482 flush-seal valve. The pin helps reduce wobble or flexing at higher rpm. 19mm agitators will fit drilled type or knob type 8076, 8078 and 8079 shafts.

  • PTFE, large-scale, multi-paddle agitator design to accept pinned bottom valves, like our 6482 flush-seal valve. The pin helps reduce wobble or flexing at higher rpm. 28mm agitators will fit drilled type 8080 shafts.

  • …plate roller or sealing paddle assures a secure uniform seal around all wells. SealPlate Ministrips Two tabs on each strip for easy application and removal Perforated tabs can be removed or sealed around plate edge Can be used as secondary seal to cover sealing films that have…

  • …end tab). Available non-sterile only. Note: Completing application of AlumaSeal 96 sealing films by pressing with an accessory film-sealing paddle assures a secure uniform seal around all wells. The paddle fits within the rim of a raised-well plate. AlumaSeal 384™ Fits standard size,…

  • …tab). Available non-sterile only. Note: Completing application of AlumaSeal 96 sealing films by pressing with an accessory film-sealing paddle assures a secure uniform seal around all wells. The paddle fits within the rim of a raised-well plate. AlumaSeal 384" Fits…

  • Benchmark Scientific

    …mixed.       Samples up to 400ml are conveniently loaded in the sterile blender bags which are sealed upon closing the door.  Mixing paddles rapidly strike the bags, producing thorough mixing and homogenization without ever directly contacting the sample. …

  • Bellco Glass

    …dual bearings and seals. A dust shield for paddle assemblies (1/4” shaft) is included.  Cap assembly features two 1/4” NPT female ports for addition of optional fittings.  Includes two 1/4” NPT male port plugs standard.  The cap assembly utilizes the unique Bellco 100 mm cap seal. The Bellco 100 mm…

  • …Once the desired sample has been added, the open top is folded over itself and the wire tie bent over the fold to seal. The multi-layer pouch is strong enough to use with a paddle blender to effectively mix the sample with the diluent. This product is made in the USA with globally sourced materials…

  • …it decreases risk of contamination. Has an adjustable shaft to align the paddle. Large paddle promotes increased oxygenation. Stainless steel shaft design prevents cell damage and minimizes magnetic decoupling. The sealed internal assembly requires less incubator space. Cap size: 100mm Sidearm cap:…

  • …it decreases risk of contamination. Has an adjustable shaft to align the paddle. Large paddle promotes increased oxygenation. Stainless steel shaft design prevents cell damage and minimizes magnetic decoupling. The sealed internal assembly requires less incubator space. Cap size: 70mm Sidearm cap:…

  • …it decreases risk of contamination. Has an adjustable shaft to align the paddle. Large paddle promotes increased oxygenation. Stainless steel shaft design prevents cell damage and minimizes magnetic decoupling. The sealed internal assembly requires less incubator space. Cap size: 70mm Sidearm cap:…

  • …it decreases risk of contamination. Has an adjustable shaft to align the paddle. Large paddle promotes increased oxygenation. Stainless steel shaft design prevents cell damage and minimizes magnetic decoupling. The sealed internal assembly requires less incubator space. Cap size: 100mm Sidearm cap:…

  • …it decreases risk of contamination. Has an adjustable shaft to align the paddle. Large paddle promotes increased oxygenation. Stainless steel shaft design prevents cell damage and minimizes magnetic decoupling. The sealed internal assembly requires less incubator space. Cap size: 70mm Sidearm: 18mm…

  • …it decreases risk of contamination. Has an adjustable shaft to align the paddle. Large paddle promotes increased oxygenation. Stainless steel shaft design prevents cell damage and minimizes magnetic decoupling. The sealed internal assembly requires less incubator space Cap size: 100mm Sidearm cap:…

  • …nylon paddle provides flexible support. The round polypropylene handle enables good control and ease of use. Features • Polyurethane foam head over flexible nylon paddle • Closed-cell structure • Round polypropylene handle • Thermal and epoxy head seal •…

  • …nylon paddle provides flexible support. The round polypropylene handle enables good control and ease of use. Features • Polyurethane foam head over flexible nylon paddle • Closed-cell structure • Round polypropylene handle • Thermal and epoxy head seal •…

  • …A rigid internal paddle provides firm support. The large polypropylene handle enables good control and ease of use. Features • Polyurethane foam head over rigid paddle • Closed-cell structure • Large polypropylene handle • Thermally sealed head • Soft…

  • …A rigid internal paddle provides firm support. The large polypropylene handle enables good control and ease of use. Features • Polyurethane foam head over rigid paddle • Closed-cell structure • Large polypropylene handle • Thermally sealed head • Soft…

  • Corning

    …(Cat. No. 3568) Recommended working range of 300mL to 1L Extended paddle design ensures constant top-to-bottom motion of the liquid without having to adjust the height of the paddle Bottom contours on the paddle hug the shape of the flask, eliminating dead spots Two wide neck openings…

  • The SV-3 is a sealed polyester swab that has been specifically designed for validation of surface cleaning protocols. The head is constructed of a double layer knitted polyester fabric that has been processed to minimize background TOC contribution. The polyester head is constructed without…

  • Sample bags are designed to withstand the paddle action of lab blenders. All standard and closure bags are made of highly transparent polypropylene and have wide-sealed bottoms to prevent leaks. Bags with 4mil wall thickness are for analyses of firmer samples. Standard bags are made with…

  • …ensures no adhesive residue and minimizes particle generation from seal. Available in increased densities for applications where particle shedding and scratching cannot be tolerated. Available in very small point and paddle style head shapes for cleaning of very small spaces. Certified…

  • …ensures no adhesive residue and minimizes particle generation from seal. Available in increased densities for applications where particle shedding and scratching cannot be tolerated. Available in very small point and paddle style head shapes for cleaning of very small spaces. Certified…

  • Stainless steel shaft design prevents cell damage and minimizes magnetic decoupling. Sealed internal assembly requires less incubator space. For use with bellco 1965-series standard and water jacketed spinner flasks Cap size: 70mm Flask size: 500ml Paddle: 2" x 2"

  • Stainless steel shaft design prevents cell damage and minimizes magnetic decoupling. Sealed internal assembly requires less incubator space. For use with bellco 1965-series standard and water jacketed spinner flasks. Cap size: 100mm Flask size: 15l Paddle: 9 1/2" x 6"

  • Stainless steel shaft design prevents cell damage and minimizes magnetic decoupling. Sealed internal assembly requires less incubator space. For use with bellco 1965-series standard and water jacketed spinner flasks. Cap size: 100mm Flask size: 500ml Paddle: 2" x 2"

  • Stainless steel shaft design prevents cell damage and minimizes magnetic decoupling. Sealed internal assembly requires less incubator space. For use with bellco 1965-series standard and water jacketed spinner flasks. Cap size: 100mm Flask size: 36l Paddle: 9 1/2" x 6"

  • Stainless steel shaft design prevents cell damage and minimizes magnetic decoupling. Sealed internal assembly requires less incubator space. For use with bellco 1965-series standard and water jacketed spinner flasks. Cap size: 100mm Flask size: 1l Paddle: 4" x 3"

  • Stainless steel shaft design prevents cell damage and minimizes magnetic decoupling. Sealed internal assembly requires less incubator space. For use with bellco 1965-series standard and water jacketed spinner flasks. Cap size: 100mm Flask size: 8l Paddle: 6 3/4" x 5"

Compare Tool

Select up to 3 products