Reference Electrode

Compare Tool

Select up to 3 products

Reference Electrode
1 - 32 of 227
Sort
View
Show

Hach

  • REF-01 Double Junction Reference Electrode

    labForce (a Thomas Scientific Brand)

    The labForce REF-01 Double Junction Reference Electrode Reference Solution: options of the first salt bridge solution and the second salt bridge solution Reference Electrode: Ag/AgCl Junction: Ceramic Dimension: Φ12x155mm Compatible labForce meters: ISE500 and M1000. May…

  • Chloride reference electrode

    Agilent Technologies

  • ISE-08 Sodium Ion-Selective Electrode

    labForce (a Thomas Scientific Brand)

    …decade Interferences: Hg2+ Features: Convenient sealed reference, and standard 12mm diameter and 120mm length The sealed, double-junction reference gives the electrode more longevity over sealed reference designs Suitable for all general purpose or more advanced applications

  • ISE-03 Silver Ion-Selective Electrode

    labForce (a Thomas Scientific Brand)

    The labForce ISE-03 Silver Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, low maintenance Silver analysis performance for many water applications. Specifications: Sensor Type: Solid State Range: 0.01-107,900 ppm Sample pH…

  • ISE-01 Fluoride Ion-Selective Electrode

    labForce (a Thomas Scientific Brand)

    The labForce ISE-01 Fluoride Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, low maintenance Fluoride analysis performance for many water applications. Specifications: Sensor Type: Solid State (LaF Crystal) Range: 0.02 to…

  • ISE-06 Calcium Ion-Selective Electrode

    labForce (a Thomas Scientific Brand)

    The labForce ISE-06 Calcium Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, low maintenance Calcium analysis performance for many water applications such as beverages, milk, aquariums, and water hardness evaluations. Specifications: …

  • ISE-04 Nitrate Ion-Selective Electrode

    labForce (a Thomas Scientific Brand)

    The labForce ISE-04 Nitrate Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, low maintenance nitrate analysis performance for many water applications such as drinking water, agriculture applications and food/beverage. Specifications: …

  • pHE-06 Premium Glass pH Electrode

    labForce (a Thomas Scientific Brand)

    …long-life reference system, which is composed of a glass tube, AgCl, and a reference silver wire. The top end of the slim glass tube is stuffed with cotton, which prevents the reaction between AgCl and electrolyte when the temperature changes. It improves the stability of reference electrode and…

  • Fluoride Ion Electrode

    Thermo Scientific Orion

    …wastewater and seawater brines and it is approved by EPA, Standard Methods and AOAC for feeds Range saturated to 0.02 ppm Requires 4215F10 reference electrode. Uses 4215F20 fill solution Accessories: Fluoride standard, 0.1000 M ±0.0005 Fluoride standard, 100 ppm ±0.5 ppm 1 or 2 ppm…

  • pHE-05 3-in-1 Glass pH/Temperature Electrode

    labForce (a Thomas Scientific Brand)

    …Long-Life Reference System is composed of a glass tube, AgCl, and a reference silver wire. The top end of the slim glass tube is stuffed with cotton, which prevents the reaction between AgCl and electrolyte when the temperature changes. It improves the stability of reference electrode and extends…

  • Reference electrode, Glass shaft, platinum junction, electrolyte KCl 3 mol/l, Ag/AgCl-reference system, coax plug head, length 120 mm, 12 mm Ø, -5...+100°C

  • ORP-01 General Purpose ORP Electrode

    labForce (a Thomas Scientific Brand)

    The labForce ORP-01 ORP Electrode is a general purpose, lab or field electrode offering affordable, low maintenance performance for many water applications. Features: Epoxy body with standard 12mm diameter and 120mm length. Sealed, gel-filled reference with double junction Ceramic…

  • PHE-12 Glass 3-in-1 pH/Temp Electrode for Dairy

    labForce (a Thomas Scientific Brand)

    Silver Ion Trap Reference System plus Protelyte Electrolyte - The PHE-12 pH/Temperature Electrode uses a Silver Ion Trap reference system and Protelyte reference solution. On top of the Long-Life reference system, a silver ion trap is added to prevent the junction from being blocked or contaminated…

  • pHE-08 Micro pH Electrode

    labForce (a Thomas Scientific Brand)

    …purpose, lab or field electrode offering affordable, low maintenance performance for applications needing a small diameter body housing (6mm) and is also longer than standard (150mm). Features: Plastic body with 6mm diameter and 150mm length Sealed, gel-filled reference with a single…

  • Electrode Reference Solution

    Wilmad-LabGlass - SP Scienceware

    Calomel Reference Electrodes utilize a 3M potassium Chloride (KCl) solution saturated with Silver Chloride (AgCl). Use it to fill or replace reference solution in any pH or other electrode which incorporates a Calomel Reference.

  • Reference electrolyte for pH electrodes (3M KCl solution saturated AgCl, 30 mL).

  • pHE-01 Basic Combination pH Electrode

    labForce (a Thomas Scientific Brand)

    …pH electrode. Ideal for regular water solutions' pH measurement in scientific research, environmental monitoring, and quality control. Measurement Range: 0–14 pH, 0–80°C (32–176°F) Housing: Polycarbonate Junction: Single Ceramic Reference Electrode: Ag/AgCl…

  • pHE-02 Basic 3-in-1 pH/Temperature Electrode

    labForce (a Thomas Scientific Brand)

    … Measurement Range: 0–14 pH, 0–80°C (32–176°F) Housing: Polycarbonate Junction: Single Ceramic Reference Electrode: Ag/AgCl Connector: BNC for pH, RCA for temperature Size: ø12x160 mm Cable: 3 Ft Temperature unit: 30KΩ Thermistor…

  • ISE-02 Chloride Ion-Selective Electrode

    labForce (a Thomas Scientific Brand)

    The labForce ISE-02 Chloride Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, low maintenance Chloride analysis performance for many water applications. Specifications: Range: 1.8-35,500 ppm Sample pH Range: 2-12 Slope: 56…

  • ISE-05 Potassium Ion-Selective Electrode

    labForce (a Thomas Scientific Brand)

    The labForce ISE-05 Potassium Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, low maintenance Potassium analysis performance for many water applications such as wastewater, agriculture applications and food/beverage. Specifications: …

  • pHE-04 Glass Combination pH Electrode

    labForce (a Thomas Scientific Brand)

    electrode adopts a Long-Life Reference System, which is composed of a glass tube, AgCl and a reference silver wire. The top end of the slim glass tube is stuffed with cotton, which prevents the reaction between AgCl and electrolyte when temperature changes. It improves the stability of reference

  • pHE-03 General Laboratory pH Electrode

    labForce (a Thomas Scientific Brand)

    The labForce pHE-03 pH Electrode is a general purpose, lab or field electrode offering affordable, low maintenance performance for many water applications. Features: Epoxy body with standard 12mm diameter and 120mm length Sealed, gel-filled reference with a double junction Ceramic…

  • pHE-07 Premium Flat pH Electrode

    labForce (a Thomas Scientific Brand)

    The labForce pHE-07 Flat pH Electrode is a general purpose, lab or field electrode offering affordable, low maintenance performance for water applications where a flat shaped pH sensor is more suitable. Features: Plastic body with standard 12mm diameter and 120mm length. Flat pH…

  • …Long-Life Reference System, improves the stability of reference electrode and prolongs the service life of the electrode. POM housing, highly resistant to corrosions. The electrode uses a BNC/RCA connector, compatible with all labForce pH meters. This is a replacement pH electrode for the labForce…

  • …and a reference silver wire. The top end of the slim glass tube is stuffed with cotton, which prevents the reaction between AgCl and electrolyte when the temperature changes. It improves the stability of the reference electrode and extends the service life of the electrode. The electrode uses a…

  • …pH electrode uses a long-life reference system, composed of a glass, AgCl and a reference silver wire. The top end of the slim glass tube is stuffed with cotton, which prevents the reaction between AgCl and electrolyte when the temperature changes. It improves the stability of reference electrode

  • PHE-18 Glass Spear pH Electrode for Semi-Solid Samples,

    labForce (a Thomas Scientific Brand)

    electrode uses a long-life reference system, composed of a glass, AgCl, and a reference silver wire. The top end of the slim glass tube is stuffed with cotton, which prevents the reaction between AgCl and electrolyte when the temperature changes. It improves the stability of the reference electrode

  • …hydrofluoric corrosion. Silver Ion Trap Reference System - The PHE-15 pH electrode uses a Silver Ion Trap reference system. On top of the Long-Life reference system, a silver ion trap is added to prevent the junction being blocked by silver sulfide. The electrode uses a BNC connector, compatible…

  • …general impact. Silver Ion Trap Reference System - The PHE-16 pH Electrode uses a Silver Ion Trap reference system. On top of the Long-Life reference system, a silver ion trap is added to prevent the junction from being blocked by silver sulfide. The electrode uses a BNC connector, compatible with…

  • …by users to ensure the best performance in every specific sample. Silver Ion Trap Reference System - The PHE-11 pH electrode uses a Silver Ion Trap reference system. On top of the Long-Life reference system, a silver ion trap is added to prevent the junction being blocked by silver sulfide.…

  • …AgCl, and a reference silver wire. The top end of the slim glass tube is stuffed with cotton, which prevents the reaction between AgCl and electrolyte when the temperature changes. It improves the stability of reference electrode and extends the service life of the electrode. The electrode uses a…

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.